• Title/Summary/Keyword: Multiple Control Valve

Search Result 33, Processing Time 0.034 seconds

Analysis of the Driving Performance in Piezo Injector for Clean Diesel Engine (친환경 디젤엔진용 차세대 피에조 인젝터의 구동성능 해석)

  • Lee, Jin-Wook;Kang, Kern-Yong;Min, Kyoung-Doug
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.33-34
    • /
    • 2006
  • In this study, a prototype piezo-driven Injector. as a new method driven by piezoelectric energy, has been designed and fabricated based on the concept of inverse piezo-electric effect to overcome the major drawbacks of conventional solenoid-driven injector with a fixed and slow control of injection rate. The effects of an electric control between the solenoid valve and piezo-ceramic stack for injector needle's driving on the dynamic characteristics were usually investigated. We found that this piezo-electric actuator has the main advantage to drastically reducing the time of injector nozzle opening, as well to exert higher force output levels.

  • PDF

TPC Algorithm for Fault Diagnosis of CAN-Based Multiple Sensor Network System (CAN 기반 다중센서 네트워크 시스템의 고장진단을 위한 TPC알고리즘)

  • Ha, Hwimyeong;Hwang, Yuseop;Jung, Kyungsuk;Kim, Hyunjun;Lee, Bongjin;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.2
    • /
    • pp.147-152
    • /
    • 2016
  • This paper proposes a new TPC (Transmission Priority Change) algorithm which is used to diagnose failures of a CAN (Controller Area Network) based network system for the oil tank monitoring. The TPC algorithm is aimed to increase the total amount of data transmission and to minimize the latency for an urgent message by changing transmission priority. The urgency of the data transmission has been determined by the conditions of sensors. There are multiple sensors inside of the oil tank, such as temperature, valve, pressure and level sensors. When the sensors operate normally, the sensory data can be collected through the CAN network by the monitoring system. However when there is a dangerous situation or failure situation happened at a sensor, the data need to be handled quickly by the monitoring system, which is implemented by using the TPC algorithm. The effectiveness of the TPC algorithm has been verified by the real experiments. In addition, this paper introduces a method that people can figure out the condition of oil tanks and also can perform the fault diagnosis in real-time by using transmitted packet data. By applying this TPC algorithm to various industries, the convenience and reliability of multiple sensors network system can be improved.

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF

A Study on the Ultra Lean Combustion Characteristics of the BMW N53 GDI Engine (BMW N53 직접분사식 가솔린 엔진의 초희박 연소특성에 관한 연구)

  • Kim, Hong-Suk;Oh, Jin-Woo;Kim, Sung-Dea;Park, Chul-Wong;Lee, Seok-Whan;Jeong, Young-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.82-89
    • /
    • 2011
  • Ultra lean combustion with stratified air-fuel mixture is one of the methods that can improve fuel economy of gasoline engines. The aim of this study is to show that how much fuel economy is improved and what are differences in engine control of the ultra lean combustion compared with stoichiometric combustion. In this study, the BMW N53 GDI engine, which is one of ultra lean combustion GDI engines introduced in the market recently, was tested at various engine operating conditions. Results indicated that fuel consumption rates were improved by 11.9~25.8% by the ultra lean combustion compared with stoichiometric combustion. It was also found that multiple fuel injection, multiple spark, early intake valve opening, and large vlave overlap duration were the features of the ultra lean combustion for combustion stability and emission improvement.

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

A Study on control mode of hybrid multi-function welder (하이브리드 다기능 용접기 제어 모드에 관한 연구)

  • Kim, Jin-Seok;Choi, Jae-Ho;Jeong, Yang-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.439-445
    • /
    • 2013
  • This study is on the system that can integrate generator and charger to use as a welder and generator for need. Specifically, it was hybrid generator consisted with select switch to use generator controller and multiple function welder, that function were auto-stopping generator when generator power finish to recharge in recharger battery and Co2 MMA TIG MIG MAG are devide depend on supplying gas. This control system of voltage, high-frequency, motor and gas valve was implemented in order to improve the performance and convenience of existing welders to choose only one or two at a time.

A study of Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer (유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구)

  • Ahn, Kyoung-Kwan;Lee, Min-Su;Cho, Yong-Rae;Yoon, Ju-Hyeon;Jo, Woo-Keun;Yoon, Hong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1075-1080
    • /
    • 2007
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

  • PDF

A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip (랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법)

  • Han, Su-Dong;Kim, Guk-Bae;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

General Anesthesia for Dental Treatment of a Pediatric Patient with Marfan Syndrome (마판 증후군 소아 환자의 전신마취 하 치과치료)

  • Kim, Kyung Jin;Bak, Soyeon;Hyun, Hong-Keun;Shin, Teo-Jeon;Kim, Jung-Wook
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.13 no.4
    • /
    • pp.209-214
    • /
    • 2013
  • Multiple caries in a pediatric patient often requires dental treatment under general anesthesia, especially when the patient is suffering from a systemic disease. The patient was a 6-year-old boy with Marfan syndrome and needed extensive dental treatment. Marfan syndrome is an inherited disorder resulting from mutations in Fibrillin-1 gene. Patients are known to have mainly cardiovascular, ocular, and musculoskeletal problems. Although clinical symptoms of the syndrome are age-realted, thus hindering early diagnosis of the disease in young children, our patient had been confirmed by a gene study at a younger age. Medical history of the patient revealed moderate to severe mitral regurgitation and aortic root dilatation, which required mitral valve replacement surgery with a mechanical valve. As a result, the patient was taking warfarin post-operatively and changes in medication had to be made before the dental treatment. Also, prophyalctic antibiotics had to be given before the treatment for prevention of (to prevent the) infective endocarditis. With careful control of the medications and bleeding tendency, general anesthesia and the treatment were done successfully without any complications.

Use of Predonated Banked Autologous Blood in Open Heart Surgery (개심술시 자가헌혈을 이용한 자가수혈의 효과)

  • 김동관
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.685-692
    • /
    • 1992
  • In spite of multiple technical advances, large amount of homologous blood transfusions usually required for open heart surgery. Because the complications associated with transfusion are increased as the number of homologous transfusion increase, especially as transfusion related acquired immunodeficiency syndrome has appeared in recent years, such risks have stimulated recent interest in the use of autologous blood. This is a report concerning 23 consecutive adult autologous donors[autologous group] who had elective cardiac surgery at the Yonsei Cardiovascular Center, Yonsei University College of Medicine, from march, 1990 to august, 1991. A similar group of 23 patients operated during the same periods without autologous blood donation was used for comparison [control group] to investigate the effect of predonated autologous blood in decreasing the need of homologous transfusion and to investigate predonation related adverse effect. Autologous group consisted of 15 men and 8 women. Control group consisted of 7 men and 16 women. There were no significant differences in mean age, hemoglobin, hematocrit, RBC count, platelet count and prothrombin time on admission between the two groups. The mean autologous blood donation in autologous group was 2.2 units. In 10[43.5%] of the 23 atuologous group patients, no homologous RBC products transfusion was required. However, all patients required homologous transfusion in control group. In autologous group, patients required less homologous RBC products than control patients[2.1 units versus 5.3 units; p<0.001]. There were no significant differences in hemoglobin, hematocrit, RBC count and platelet count between the two groups before discharge. There were no serious complications related to preoperative blood donation, although 3 patients complained of mild dizziness during donation We conclude that preoperative autologous predonation of blood is a safe and effective method for reducing homologous transfusion and is recomended in all patients undergoing elective cardiac surgery except limited contraindications such as severe aortic valve stenosis or unstable angina pectoris.

  • PDF