Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

다중 추적자 영상을 위한 컴프턴 카메라 (Multi-tracer Imaging of a Compton Camera)

  • 김수미
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.18-27
    • /
    • 2015
  • 컴프턴 산란 현상을 이용하여 전자적 집속 방법으로 영상화하는 컴프턴카메라는 고민감도 및 고에너지 해상도의 장점을 이용하여 핵의학 응용분야에 대한 잠재력이 큰 영상 시스템이다. 본 논문에서는 컴프턴카메라를 이용한 다중 추적자 영상의 효용성 평가와 정확한 3차원 단면영상 촬영을 위한 Orlov 조건을 만족하는 회전하는 컴프턴카메라의 구조를 조사하였다. 140/511 keV의 방사선원의 소프트웨어 모형을 구성하고 이에 대한 몬테카를로 전산모사 시뮬레이션을 수행하여 리스트모드 배열된 부분집합 기댓값 최대화 방법으로 재구성된 다중 추적자 영상으로 컴프턴카메라의 효용성을 검증하였다. 산란부와 흡수부를 평행하게 위치시킨 고정된 컴프턴카메라와 촬영대상 주위 $360^{\circ}$를 회전하는 컴프턴카메라를 구성하여 검출된 투사선의 구좌표계 각도에 대한 히스토그램을 비교 평가하였다. 140/511 keV의 동시 계측된 몬테카를로 전산모사 데이터의 다중 추적자 영상이 2차원 및 3차원 재구성 시 잘 구분되는 것을 확인하였으며, 회전된 컴프턴카메라의 경우, 회전각도에 반비례하여 3차원 영상재구성에 필요한 유효 투사선이 증가하였다. 26분의 계산 시간 및 5백만개의 적절한 유효 투사선의 개수를 고려할 때 컴프턴카메라의 회전각은 $30^{\circ}$가 현실적으로 적절할 것이며 증가한 검출 시간은 다중 컴프턴카메라를 구성하여 해결할 수 있다. 본 논문에서 고찰한 고민감도 및 고에너지 해상도를 가진 컴프턴 카메라는 다중추적자 영상화를 위해 적합한 시스템이며 생화학 및 생리학적 상태 변화에 대한 임상 정보를 제공하며 각종 질병 진단 및 치료 방법 개발 등에 기여할 수 있는 잠재력이 있는 영상 시스템이다.

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

  • Lee, Jun;Kim, Younghak;Bolotnikov, Aleksey;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4080-4092
    • /
    • 2021
  • In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm3. The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80%), while those evaluated using the minimum squared difference method (55-59%) and Three Compton method (45-55%) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가 (Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering)

  • 김노유
    • 비파괴검사학회지
    • /
    • 제30권1호
    • /
    • pp.46-53
    • /
    • 2010
  • 항공기용 복합재료 내부 여러 층에서 발생하는 박리를 정량적으로 평가하기 위한 X-ray 후방산란 검사장치를 개발하였다. 복합재료 두께방향으로의 역산란 밀도변화로부터 층간 박리를 검사하는 슬릿 방식의 카메라와 컴퓨터로 제어되는 X-ray 선원, 그리고 센서로 구성되는 X-ray 후방산란장치를 제작하여 그 성능을 충격하중에 의해 만들어진 인공결함시편을 이용해 검증하였다. 결함평가를 위해 복합재료내 산란장의 크기를 이론적으로 계산하는 수학적 해석 모델을 볼츠만 방정식을 이용하여 제안하였으며 적응필터 알고리즘을 사용하여 산란 노이즈를 최소화 하였다. 다중 박리 결함을 X-ray 후방산란장치를 통해 효과적으로 검출하였으며, 박리 위치와 박리 상태를 모두 정확하게 검사할 수 있음을 실험을 통해 확인하였다.