• 제목/요약/키워드: Multiple CAM

검색결과 92건 처리시간 0.021초

Integration of Stress-Strain Rate Equations of CASM

  • Koh, Tae-Hoon
    • International Journal of Railway
    • /
    • 제3권4호
    • /
    • pp.117-122
    • /
    • 2010
  • In transportation geotechnical engineering, stress-strain behavior of earth structures has been analyzed by numerical simulations with the implemented plasticity constitutive model. It is a fact that many advanced plasticity constitutive models on predicting the mechanical behavior of soils have been developed as well as experimental research works for geotechnical applications in the past decades. In this study, recently developed, a unified constitutive model for both clay and sand, which is referred to as CASM (clay and sand model), was compared with a classical constitutive model, Cam-Clay model. Moreover, integration methods of stress-strain rate equations using CASM were presented for simulation of undrained and drained triaxial compression tests. As a conclusion, it was observed that semi-implicit integration method has more improved accuracy of capturing strain rate response to applied stress than explicit integration by the multiple correction and iteration.

  • PDF

Total joint reconstruction using computer-assisted surgery with stock prostheses for a patient with bilateral TMJ ankylosis

  • Rhee, Seung-Hyun;Baek, Seung-Hak;Park, Sang-Hun;Kim, Jong-Cheol;Jeong, Chun-Gi;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.41.1-41.6
    • /
    • 2019
  • Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.

CAD/CAM을 이용하여 제작한 전부도재관의 지르코니아 코핑 디자인에 따른 파절강도에 관한 연구 (A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System)

  • 로도이 볼강;조인호;신수연
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.111-123
    • /
    • 2006
  • A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System L. Bulgan, In-Ho Cho, Soo-Yeon Shin Department of Prosthodontics, Graduate School, Dankook University The fracture strength of prosthesis is important, because it affects the function, and long term success of prosthesis and teeth. The purpose of this study was to compare the fracture strength of zirconia coping designs. Experimental test group were classified into three designs according to coping design, Modified design: Zirconia coping margin was located at 1mm above the axiogingival line angle. Collarless design: The coping margin terminated at the axiogingival line angle Butt design: The coping margin was extended to the finishing line of prepared margin. A $Cercon^{(R)}$(Degussa, Germany) CAD/CAM system was used to make the zirconia coping. Fracture strength was measured using loading machine at a cross head speed of 1mm/min. The results were statistically analyzed using the one-way ANOVA and multiple comparison test. Statistical significance was set in advance at the probability level of less than 0.05. The result : I. Collarless($738N{\pm}155N$) and Modified($755N{\pm}185N$) groups showed significantly a lower fracture strength than Butt($1057N{\pm}262N$) group(p<0.05). II. There were no statistical differences of the fracture strength between Modified($755N{\pm}185N$) and Collarless($738N{\pm}155N$) groups. III. When comparing the fractured surface, all the group showed porcelain fracture, which were fractured at the labial surface of baked porcelain The butt design of the zirconia coping has higher fracture strength than modified and collarless design.

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

다중 토출 레이디얼 유압 피스톤 펌프의 압력 맥동 특성 (Pressure Pulsation Characteristics of a Multiple-Delivery Radial Piston Hydrulic Pump)

  • 최세령;임종철;이일영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, the authors carried out experiments and numerical simulations in order to clarify the pressure pulsation characteristics in multiple-delivery rotating-cam and stationary-cylinder type radial piston pumps. Also, a tee filter was applied to the pump in order to mitigate the pressure pulsation. Through the experiments and simulations, it was known that pressure pulsation with a magnitude higher than 40% of the mean load pressure could occur in the pump used in the experiments. Moreover, it was confirmed that a tee filter designed in this study could effectively mitigate the pressure pulsation.

복합형상 및 다중경로에 대한 Exit Burr 판별 알고리듬의 개발- 스플라인을 포함한 Exit Burr의 해석 - (Development of Exit Burr Identification Algorithm on Multiple Feature Workpiece and Multiple Tool Path)

  • 김지환;이장범;김영진
    • 산업공학
    • /
    • 제18권3호
    • /
    • pp.247-252
    • /
    • 2005
  • In the automated production environment in the present days, the minimization of manual operation becomes a very important factor in increasing the efficiency of the production system. The exit burr produced through the milling operation on the edge of workpiece usually requires manual deburring process to enhance the level of precision of the resulting product. So far, researchers have developed various methods to understand the formation of exit burr in cutting process. One method to analytically identify the formation of exit burr was to use the geometrical information of CAD and CAM data used in automated machining. This method, in turn, generated the information resulting from the analysis such as burr type, cutting region, and exit angle. Up to now, the geometrical data were restricted to the single feature and single path. In this paper, a method to deal with the complicated geometric features such as line segment, arc, hole, and spline will be presented and validated using the field data. This method also deals with the complex workpiece shape which is a combination of multiple features. As for the cutting path, multiple tool path is analyzed in order to simulate the real cutting process. All this analysis is combined into a Windows based software and real data are used to validate the program in the conclusion.

진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고 (Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report)

  • 현상우;이성복;이석원;조영은
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.478-486
    • /
    • 2021
  • 치과와 기공실을 오가며 복잡하게 진행되는 기존 CAD-CAM 컴퓨터 가이드 제작 방식을 단 순화하기 위하여, 진료실에 설치한 바로가이드 시스템(VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea)을 통하여 Top-Down 개념과 수복 주도개념을 적용하여 1-day 수술과 임시보철을 완료하는 증례를 보고하고자 한다. Pre-Guide를 통해 환자의 중심위에서 교합을 채득하고 CT를 촬영하며, 진료실 내 컴퓨터에서 CAD를 통해 바로가이드를 1시간 내에 제작하였다. 미리 제작된 광중합 레진이 담긴 Pre-Guide 트레이를 술부에 위치시킨 후 중심위에서 CT를 촬영하였다. CT 데이터가 진료실 내 컴퓨터로 전송되면 수복 위치를 정한 후 이어서 3차원적으로 턱뼈에서 임플란트를 식립할 위치를 디자인하여 STL 파일로 추출하였다. 그리고 진료실에 설비된 밀링 기계(VARO-mill)에 Pre-Guide를 고정하여 수술용 가이드를 15분 내에 제작한다. 이 가이드로 환자는 한번 내원하여 임플란트를 계획한 위치에 안전하고 정확하게 수술해 줌과 더불어, 초기고정력이 양호한 임플란트에 대해서는 즉시임시치아까지 장착해 주어 환자에게 즉시 기능이 가능하도록 할 수 있었다.

아토피 피부염 환아의 보완대체요법 이용 실태 (A Study on the Utilization of Complementary and Alternative Medicine on Children with Atopic Dermatitis)

  • 김채봉;김규상
    • 한국콘텐츠학회논문지
    • /
    • 제17권1호
    • /
    • pp.58-68
    • /
    • 2017
  • 아토피 피부염은 학령기 전과 후 아동에서 유병률이 높은 것으로 알려져 있다. 또한 일반인뿐만 아니라 아토피 피부염 환자에서도 보완대체요법의 이용률이 증가하고 있다. 본 연구는 아토피 피부염 아동의 보완 대체요법에 대한 이용 실태를 파악하고 이에 대한 기초 근거를 마련하는데 있다. 연구 대상은 2010년 '서울시 아토피 천식 안심학교' 사업에 참여한 아동으로 6,800명의 아토피 피부염 아동 중에서 무응답을 제외하고 4,985명을 최종분석에 활용하였다. 독립변인은 연령, 가구 월 소득, 수면장애이었고 종속변인은 지난 12개월 동안의 병원 이용 경험, 한의원 이용 경험, 민간요법 이용 경험이었다. 연구결과, 병의원 치료 이용은 76.5%, 한의원(한방병원) 이용은 24.6%, 민간요법 이용은 62.3%, 한의원(한방병원)과 민간요법의 중복 이용은 2.1%, 병의원 치료와 민간요법의 중복 이용은 34.2%, 병의원 치료와 한의원(한방병원), 민간요법의 중복 이용은 18.8%이었다. 그리고 보완대체요법 이용에 영향을 미치는 변인으로는 연령, 가구 월 소득, 수면장애인 것으로 나타났다. 그러나 일부 보호자들은 오랜 통념으로 민간요법이 더 효과적이고 안전하다고 인식하는 경향이 있다. 따라서 보완대체요법에 대한 장단점을 의료진과 상담한 후 이용하는 것이 바람직하다.

구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례 (Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system)

  • 정지원;허성주;김성균;곽재영
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.44-54
    • /
    • 2022
  • 다수 치아의 상실 상태로 장시간 지속시 구치부 지지의 부족 및 치아들의 과정출이 발생되어 교합 부조화, 수직고경 상실 및 기능 장애 등의 심각한 문제가 초래된다. 본 증례는 장기간 다수치아 결손으로 인하여 대합치가 정출하면서 교합평면의 붕괴가 일어난 환자의 완전 구강 회복에 관한 증례이다. 상기 환자는 서울대학교 치과병원 치과보철과로 내원한 68세 남환으로 오래된 상악 의치를 빼다가 치아가 함께 발거되었으며, 하악 전치부가 상악 전치부와 강하게 닿아서 불편함을 호소하며 내원하였다. 여러가지 평가를 통해 수직고경을 4 mm 거상하였으며, 무치악부는 진단 및 치료계획시 설계한 최종 보철 수복물 제작을 고려하여 정확한 임플란트 식립을 위해 CAD-CAM (Computer-aided design-computer-aided manufacturing) 기술을 이용한 Computer guided implant surgery를 시행하고, 임플란트 고정성 보철 수복으로 진행하였고, 환자는 저작, 기능 및 심미 모두 큰 개선에 만족하였다.

소수의 동력장치와 메커니즘을 이용한 다수의 객체움직임 디자인에 관한 연구 (A Study on the Design of Multiple Object Movements Using Few Power Units and Machanisms)

  • 강희라
    • 디지털융복합연구
    • /
    • 제18권12호
    • /
    • pp.543-548
    • /
    • 2020
  • 본 연구는 다중의 동력장치를 이용하여 다수의 객체를 움직이는 키네틱 디자인작품을 제작하면서 다수의 객체를 소수의 동력장치를 이용하여 다수의 동력장치를 이용한 것 같은 다양한 움직임을 구현할 수 있게 하는 것이 목적이다. 다수의 객체를 다양하게 움직이기 위해선 다수의 동력장치를 사용하여 움직임을 나타내는 것이 일반적인 방법이나 이렇게 하면 객체만큼의 많은 동력장치를 이용해야 하며 과다한 동력장치 사용으로 비용의 상승과 작품무게가 증가하게 된다. 많은 동력장치를 움직이기 위한 많은 전력 소모를 하게 된다. 이에 소수의 동력장치로 다수의 객체를 다양한 움직임을 통해 제어할 수 있는 메커니즘을 작품에 적용하여 실험하였다. 메커니즘을 이용해 다수의 객체를 움직이면 작품의 무게와 전력 소모량을 현저하게 줄일 수 있었다. 또한, 캠의 위치와 모양을 변경한 캠샤프트 구조의 이용과 베벨기어의 이용을 통해 객체의 행과 열을 늘려 다양한 움직임을 표현할 수 있었다. 본 연구를 통해 키네틱 디자인 작품을 제작하는 많은 디자이너에게 다수의 객체를 제어하는 하나의 또 다른 방법을 제시하게 된다.