• Title/Summary/Keyword: Multilevel Method

Search Result 294, Processing Time 0.026 seconds

Design of Decentralized Multilevel-Multiple Model Adaptive Controller(DM-MMAC) for Power Plant (발전플랜트를 위한 분산다단계-다중모델 적응제어기의 설계)

  • 최선욱;이은호;박용식;김영철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1119-1125
    • /
    • 1999
  • In this paper, a decentralized multilevel-adaptive controller for a boiler-turbine system is designed by using multiple model adaptive method. It is applied to the drum type boiler-turbine system which is simplified from Boryung T/P #1,2 model. A linearlized model is decomposed into three subsystems by means of linear transformation. Then the DMC based on such subsystem is designed and a Multiple Model Adaptive Control(MMAC) scheme is applied for the purpose of the good tracking to variable load demands of the thermal power plant. The good performance of the designed controller is shown by simulations in various conditions that have the large step and ramp change of power demamd.

  • PDF

A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 새로운 직류전압 평형기법)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.144-148
    • /
    • 2003
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

A Study on Filter Efficiency Analysis and Harmonic Reduction of Single Phase NPC Multi-Level Inverter with LC-Trap Filter (LC트랩필터를 갖는 단상 NPC 멀티레벨 인버터의 출력 고조파 저감 및 필터 효율 분석에 관한 연구)

  • Kim Soo-Hong;Seo Kang-Moon;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.430-435
    • /
    • 2006
  • This paper presents a method about the efficiency analysis and the harmonic reduction of single phase NPC multi-level inverter with LC-trap filter and LCR output filter. The proposed LC-trap filter is comprised of a conventional LC output filter, by using LC-trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also, low damping resistor is increased the efficiency of the output filter. Experimental verification of the proposed circuit is provided with single phase NPC multilevel inverter system and DSP controller.

Reproducible Chemical Mechanical Polishing Characteristics of Shallow Trench Isolation Structure using High Selectivity Slurry

  • Jeong, So-Young;Seo, Yong-Jin;Kim, Sang-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.5-9
    • /
    • 2002
  • Chemical mechanical polishing (CMP) has become the preferred planarization method for multilevel interconnect technology due to its ability to achieve a high degree of feature level planarity. Especially, to achieve the higher density and greater performance, shallow trench isolation (STI)-CMP process has been attracted attention for multilevel interconnection as an essential isolation technology. Also, it was possible to apply the direct STI-CMP process without reverse moat etch step using high selectivity slurry (HSS). In this work, we determined the process margin with optimized process conditions to apply HSS STI-CMP process. Then, we evaluated the reliability and reproducibility of STI-CMP process through the optimal process conditions. The wafer-to-wafer thickness variation and day-by-day reproducibility of STI-CMP process after repeatable tests were investigated. Our experimental results show, quite acceptable and reproducible CMP results with a wafer-to-wafer thickness variation within 400$\AA$.

Preliminary Research on the Uncertainty Estimation in the Probabilistic Designs

  • Youn Byung D.;Lee Jae-Hwan
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.1
    • /
    • pp.64-71
    • /
    • 2005
  • In probabilistic design, the challenge is to estimate the uncertainty propagation, since outputs of subsystems at lower levels could constitute inputs of other systems or at higher levels of the multilevel systems. Three uncertainty propagation estimation techniques are compared in this paper in terms of numerical efficiency and accuracy: root sum square (linearization), distribution-based moment approximation, and Taguchi-based integration. When applied to reliability-based design optimization (RBDO) under uncertainty, it is investigated which type of applications each method is best suitable for. Two nonlinear analytical examples and one vehicle crashworthiness for side-impact simulation example are employed to investigate the unique features of the presented techniques for uncertainty propagation. This study aims at helping potential users to identify appropriate techniques for their applications in the multilevel design.

Performance-Driven Multi-Levelizer for Multilevel Logic Synthesis (다단 논리합성을 위한 성능 구동형 회로 다단기)

  • 이재흥;정정화
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.132-139
    • /
    • 1993
  • This paper presents a new performance-driven multi-levelizer which transforms a two-level description into a boolean network of the multilevel structure satisfied with user's costraints, such as chip area, the number of wires and literals, maximum delay, function level, fanin, fanout, etc.. The performance of circuits is estimated by reference to the informations in cell library through the cell mapping phase, and multi-levelization of circuits is constructed by the decomposition using the kernel and factoring concepts. Here, the saving cost of a common subexpression is defined to the sum of area and delay saved, when it is substituted. The experiments with MCNC benchmarks show the efficiency of the proposed method.

  • PDF

A Study on the Output Noise Reduction of 3-Phase Multilevel Inverter (3상 멀티레벨 인버터 출력노이즈 저감에 관한 연구)

  • Kim, Soo-Hong;Jin, Kang-Hwan;Kin, Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.101-103
    • /
    • 2007
  • Since they use the low switching frequency in multilevel inverter systems, they generate the high low frequency harmonic components. Generally, LC filter is used at the output terminal of inverter systems to solve this problem. But it causes a voltage drop at the output terminal by use of damping resistors, and causes the problem in which system efficiency decreases due to power loss of the damping resistor. In this paper, we proposed an output filter design method for NPC three-level inverter systems with low switching frequency. And we analyzed the efficiency of the proposed filter system, and the effectiveness of the proposed system is verified by simulation and experimental results.

  • PDF

Control method for Modular Multilevel Converter to reduce switching losses (스위칭 손실을 줄이기 위한 모듈형 멀티레벨 컨버터의 제어 방법)

  • Park, So-Young;Kim, Jae-Chang;Kwak, SangShin
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.22-23
    • /
    • 2017
  • 본 논문에서는 모듈형 멀티레벨 컨버터 (Modular Multilevel Converter; MMC)의 스위칭 손실을 줄이기 위한 모델 예측 제어 (Model Predictive Control; MPC) 방법을 제안한다. 제안된 방법은 지령 상 전압과 상 전류를 이용하여 매 샘플링 시점 마다 전류가 크게 흐르는 구간 동안 서브모듈의 스위칭 동작을 클램핑 시키는 옵셋전압을 계산한다. 제안된 방법의 스위칭 손실 저감 효과는 기존의 방법과의 손실 데이터 비교를 통하여 검증되었다.

  • PDF

The Power Module DC Measurement Method of Modular Multilevel Converter System using SPI Communication (SPI 통신을 이용한 MMC 시스템의 Power Module DC 센싱 방법)

  • Lee, Jong-Hak;Shin, Yesl;Kim, Jun-Gu;Kwon, Byung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.53-54
    • /
    • 2014
  • MMC(Modular Multilevel Converter)는 여러 개의 Power Module을 직렬로 연결하여 정현파에 가까운 고전압의 파형을 얻을 수 있는 토폴로지로 대용량 전력변환 분야의 요구를 만족하면서 전력 품질을 향상시킬 수 있어 근래에 상당히 주목받고 있다. 당사에서는 5Mvar급 STATCOM(STATic synchronization COMpensator)을 MMC 형태로 제작하였다. 1개의 Cell 제어기는 6대의 Power Module의 제어와 보호를 담당하여 DC 전압을 센싱하여야 한다. 본 논문에서는 제안한 SPI(Serial Peripheral Interface) 통신을 이용하여 Power Module을 제어하기 위해 DC 센싱 방법에 대해 설명한다.

  • PDF

Grid Voltage Regulation with MMC-HVDC System

  • Quach, Ngoc-Thinh;Jeong, Woo-Cheol;Yang, Hang-Jun;Choi, Jong-Yun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.146-147
    • /
    • 2014
  • This paper presents an operation of the modular multilevel converter-high voltage direct current (MMC-HVDC) system as a Statcom to support the grid voltage. The advantage of the MMC-HVDC system is that it can control the active and reactive powers independently. The proposed control scheme will be designed by combining this performance and the control method of the Statcom. The grid voltage is regulated by the control of the reactive power, meanwhile the active power is controlled according to its applications. The simulation results based on the PSCAD/EMTDC simulation program will evaluate the effectiveness of the control scheme.

  • PDF