• 제목/요약/키워드: Multi-wires

검색결과 107건 처리시간 0.021초

고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설 (Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field)

  • 임형우;이동민;윤기현;차귀수;이희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

1세대 선재와 2세대 선재의 혼합 적층에 따른 자화손실 특성 (Magnetization loss of Hybrid Multi-Stacked wire made of 1G wires and 2G wires)

  • 임형우;이용석;이희준;차귀수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.57-60
    • /
    • 2007
  • Superconducting electric power devices need to stack HTS wires to increase the current carrying capacity. Uniform multi-stacked wires(UMS) which were made of the same HTS wires have been used. This paper shows the magnetization loss of hybrid multi-stacked(HMS) wire made of BSCCO wires and YBCO wires. Five HMS wires, YB(YBCO-BSCCO), YYBB. YBYB, YBBY and BYYB, were made and tested. Magnetization losses of each UMS wire were compared with corresponding HMS wire. Test results show that magnetization losses per unit length of HMS wire are between the corresponding UMS BSCCO wire and HMS YBCO wire below critical magnetic field. Above the critical magnetic field, magnetization losses of HMS wires are larger than that of corresponding both VMS wires.

Comparison of Magnetization loss of YBCO wires and BSCCO Wires

  • Lim Hyoung-Woo;Lee Hee-Joon;Cha Guee-Soo;Lee Ji-Kwang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.33-36
    • /
    • 2006
  • Multi-stacked HTS wires are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO wire and the BSCCO wire have been measured and compared. 4 types of YBCO wires and BSCCO wires, that is, single, 2-stacked, 3-stacked and 4-stacked, have been tested. HTS multi-stacked wires were fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of HTS wires. The ratios of the magnetization loss by multiple stacking of superconducting wires were presented. Measurements results show that loss reduction ratios have three distinct regions due to the magnitude of external magnetic field, the material of HTS wire and number of stacks.

절연거리 변화에 따른 적층된 YBCO 도체의 자화손실 변화 (Effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor)

  • 임형우;이희준;차귀수;이지광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.95-97
    • /
    • 2005
  • Loss in the multi-stacked HTS wires are affected by a number of factor, such as, number of wires used in the stack, direction of external magnetic field and insulation thickness between the wire. This paper examines the effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor. Measurements of magnetization loss were performed using 4 different typo of multi-stacked wires and under various angle of external magnetic field. Test results show that loss density per unit volume increased for YBCO coated conductors when thickness of insulation increased. Loss density per unit volume decreased for YBCO coaled conductors when stacking number of tapes increased.

  • PDF

Half-cell 기반 multi-wires 접합 공정에서 접합 특성에 영향을 주는 요인과 효율의 상관관계 연구 (A Study on the Relationship between Factors Affecting Soldering Characteristics and Efficiency of Half-cell Soldering Process with Multi-wires)

  • 김재훈;손형진;김성현
    • Current Photovoltaic Research
    • /
    • 제7권3호
    • /
    • pp.65-70
    • /
    • 2019
  • As a demand of higher power photovoltaic modules, shingled, multi-busbar, half-cell, and bifacial techniques are developed. Multi-busbar module has advantage for large amount of light havesting. And, half-cell is high power module for reducing resistive losses and higher shade tolerance. Recently, researches on multi-busbar is focused on reliability according to adhesion and intermetallic compound between Sn-Pb solder and Ag electrode. And half-cell module is researched to comparing with full-sized cell module for structure difference. In this study, we investigated the factors affecting to efficiency and adhesion of multi-wires half-cell module according to wire thickness, solder thickness, and flux. The results of solar simulator and peel test was that peel strength and efficiency of soldered cell is not related. But samples with flux including high solid material showed high efficiency. The results of FE-SEM and EDX line scan on cross-section between wire and Ag electrode for different flux showed thickness of solder joint between wire and Ag electrode is increasing through solid material increasing. Flux including high solid material would affect to solder behavior on Ag electrode. Higher solid material occurred lower growth of IMC layer because solder permeate to sider of wire ribbon than Ag electrode. And it increased fill factor for high efficiency. In soldering process, amount of solid material in flux and solder thickness are the factor related with characteristic of soldered photovoltaic cell.

Overview of MgB2 superconducting conductors at Sam Dong in Korea

  • Choi, Jun Hyuk;Lee, Dong Gun;Kim, Du Na;Yoon, Gi Yeong;Jeon, Ju Heum
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권2호
    • /
    • pp.32-37
    • /
    • 2020
  • Sam Dong Co., Ltd. has been succeeded in producing a 1 km multi-filament conductor in 2018. So far, we become more widespread to fabricate a variety of customized multi-filament wires such as 6 + '1' Cu, 18 + '1' Cu, and 36 + '1' Cu. In this work, we discuss the research progress on various MgB2 wires over the past three years. We also provide a brief review for applications with our wires.

자동차 임의배선에 의한 화재발생 가능성 연구 (Study on the Possibility of Car Fire by Arbitrary Electrical Wiring)

  • 김민;윤장수
    • 한국화재조사학회학술대회
    • /
    • 한국화재조사학회 2011년도 제20회 추계학술대회
    • /
    • pp.91-119
    • /
    • 2010
  • 자동차 수의 증가와 함께 자동차 화재 또한 꾸준한 증가 추세에 있다. 본 연구에서는 자동차 화재의 여러 요인들 중 자동차 출고 이후에 사용자에 의하여 변형된 부분, 즉 자동차 튜닝으로 인하여 화재가 발생할 가능성을 입증하고자 하였다. 실험 결과 전조등의 밝기를 향상시키기 위한 교체, 멀티시거잭 배선의 허용전류를 초과하여 전기장치를 사용하는 경우, 전선의 손상, 그리고 시중에서 튜닝용으로 구입하여 사용하는 전기배선의 취약성 등이 화재 가능성에 영향을 미치는 것으로 나타났다.

  • PDF

Self-centering passive base isolation system incorporating shape memory alloy wires for reduction in base drift

  • Sania Dawood;Muhammad Usman;Mati Ullah Shah;Muhammad Rizwan
    • Smart Structures and Systems
    • /
    • 제31권5호
    • /
    • pp.531-543
    • /
    • 2023
  • Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.

고탄소강 다단 신선 와이어의 표면 잔류응력 예측모델 (Prediction Model of Surface Residual Stress for Multi-Pass Drawn High Carbon Steel Wire)

  • 김대운;이상곤;김병민;정진영;반덕영;이선봉
    • 소성∙가공
    • /
    • 제19권4호
    • /
    • pp.224-229
    • /
    • 2010
  • During the multi-pass wire drawing process, wires suffer a great amount of plastic deformation that is through the cross-section. This generates tensile residual stress at surface of drawn wires. The generated residual stress on surface is one of the problems for quality of wires so that prediction and reduction of residual stresses is important to avoid unexpected fracture. Therefore, in this study, the effect of process variables such as semi-die angle, bearing length and reduction ratio on the residual stress was evaluated through Finite Element Analysis. Based on the results of the Analysis, a prediction model was established for predicting residual stress on the surface of high carbon steel(AISI1072, AISI1082). To identify the effectiveness of the proposed model, X-ray diffraction is used to measure the residual stresses on the surface. As the result of the comparison between calculated residual stresses and measured residual stresses, the model could be used to predict residual stresses in cold drawn wire.

Bi-2223/Ag 고온 초전도 선재의 임계전류 및 소세징에 미치는 인발 조건의 영향 (The Influence of Drawing Parameters on Sausaging and Critical Current of Bi-2223/Ag HTS Wires.)

  • 하홍수;오상수;하동우;김상철;권영길;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.488-491
    • /
    • 2000
  • Bi-2223/Ag superconducting wires have been mainly prepared by a powder-in-tube method. The drawing and the rolling are main processes to increase the core density and wire length. In the fabrication of long wire, especially, the drawing should be precisely controlled to assure the filament homogeneity. In this paper, the influences of drawing die angle, bearing length and reduction ratio on the sausaging and the critical current density of the wire are investigated. Single cored and multi-filamentary wires are fabricated by PIT method with different conditions. The core densities and sausaging in the wires are investigated and are discussed regarding their relationship to the I$_{c}$. It was made clear that the geometry of drawing die is sensitively dependent on the sausaging. The improvement of I$_{c}$ was achieved by reducing the die angle and high core density.ity.

  • PDF