• Title/Summary/Keyword: Multi-therapy

Search Result 377, Processing Time 0.028 seconds

Effects of Multi-site and Single-site Functional Massage and Stretching on Pain, Tenderness Threshold and Grip Strength in Patients with Lateral Epicondylalgia (가쪽위관절융기 통증 환자에서 복합 부위와 단일 부위에 기능적 마사지와 스트레칭을 적용할 때 통증, 압통 역치와 악력에 미치는 영향)

  • Min-keun Jung;Jae-guk Jeon;Eui-joo Shin
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.13-22
    • /
    • 2023
  • Background: The purpose of this study was to investigate the effects of functional massage and stretching, applied to the elbow and shoulder joints, on pain, tenderness threshold, and grip strength. Methods: A total of 29 individuals were assigned to a single site (n=15) or multiple sites (n=14). Pain measured through the visual analogue scale (VAS), tenderness threshold (TTH), and grip strength (GI) were measured before and four weeks after the intervention. Results: After four weeks of treatment, visual analogue scale significantly decreased in both groups (p<.05), and the tenderness threshold and grip strength significantly increased in both groups (p<.05). There was also a significant difference between the two groups (p<.05). Conclusion: The reduction of visual analogue scale and the increase in the tenderness threshold and grip strength were more significant in the multi-site treatment group than in the single-site treatment group.

  • PDF

Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Kim, Chan Hyeong;Lee, Han Rim;Jeong, Jong Hwi;Lee, Se Byeong;Shin, Dong Ho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1406-1416
    • /
    • 2019
  • In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed $3.8{\times}10^8$ protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation.

Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Chan Hyeong;Shin, Dong Ho;Jeong, Jong Hwi
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.533-538
    • /
    • 2019
  • The mechanical-collimation imaging is the most mature technology in prompt gamma (PG) imaging which is considered the most promising technology for beam range verification in proton therapy. The purpose of the present study is to compare the performances of two mechanical-collimation PG cameras, knife-edge (KE) camera and multi-slit (MS) camera. For this, the PG cameras were modeled by Geant4 Monte Carlo code, and the performances of the cameras were compared for imaginary point and line sources and for proton beams incident on a cylindrical PMMA phantom. From the simulation results, the KE camera was found to show higher counting efficiency than the MS camera, being able to estimate the beam range even for $10^7$ protons. Our results, however, confirmed that in order to estimate the beam range correctly, the KE camera should be aligned, at least approximately, to the location of the proton beam range. The MS camera was found to show lower efficiency, being able to estimate the beam range correctly only when the number of the protons is at least $10^8$. For enough number of protons, however, the MS camera estimated the beam range correctly, errors being less than 1.2 mm, regardless of the location of the camera.

Update of Sepsis: Recent Evidences about Early Goal Directed Therapy

  • Cho, Woo Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.3
    • /
    • pp.156-160
    • /
    • 2015
  • Severe sepsis and septic shock is a life-threatening disease. It is combined with multi-organ failure. In the past decade, early goal directed therapy has been proposed as an effective treatment strategy for better outcome. Recent epidemiologic studies showed that the outcome of sepsis has been improved with the introduction of early goal directed therapy. However, it is unclear which elements of early goal directed therapy contributed to the better outcome. Recent prospective and randomized trials suggested that some elements of early goal directed therapy did not have any effect on the outcome benefit. In this paper, recent articles about early goal directed therapy will be reviewed and the effectiveness of individual elements of early goal directed therapy will be discussed.

The Current Status of Adenovirus-based Cancer Gene Therapy

  • Shirakawa, Toshiro
    • Molecules and Cells
    • /
    • v.25 no.4
    • /
    • pp.462-466
    • /
    • 2008
  • Adenoviruses are the most commonly used gene-delivery vectors due to the efficiency of their in vivo gene transfer. Since 1993, about 300 protocols using an adenoviral vector have been performed, although they have yet to be proven effective in clinical trials. The adenovirus-based vector has been continuously improved by modification of the adenoviral genome and capsid, and novel adenovirus-delivery systems, such as the carrier-cell delivery system, have been recently proposed. Adenovirus-based cancer gene therapy is fast becoming one component of a multi-modality treatment approach to advanced cancer, along with surgery, radiotherapy, and chemotherapy.

The Effect of Task-Oriented Multi-Sensory Movement Program on Self-efficacy and Writing Ability of Children with ADHD Tendency Accompanied by Learning Delays (과제 중심 다감각운동 프로그램이 학습지연을 동반한 ADHD성향 아동의 자아효능감과 쓰기능력에 미치는 변화)

  • Roh, Heo-Lyun;Kwag, Sung-Won
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.8 no.2
    • /
    • pp.1-14
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the change in self-efficacy and writing ability after applying a Task-Oriented Multi-Sensory Movement Program to children with ADHD tendency accompanied by learning delays. Methods : A Task-Oriented Multi-Sensory Movement Program was implemented to children with ADHD tendency accompanied by learning delays attending S elementary school. The research proceeded in the order of a pre-test, Task-Oriented Multi-Sensory Movement intervention, and a post-test. The first session involved a pre-test, in which the children's self-efficacy and writing ability were examined using self-efficacy test and type 'A' KNISE-BAAT writing test. The multisensory group activity program intervention was conducted for a total of 8 sessions. In the last session, a post-test was conducted using self-efficacy test and type 'B' KNISE-BAAT writing test. Data collected from the tests were analyzed using SPSS Statistics 18. Results : According to the tests taken before and after implementing the Task-Oriented Multi-Sensory Movement Program, there was a significant improvement in self-efficacy (school, society), writing ability(command of vocabulary and sentence). Conclusion : Task-Oriented Multi-Sensory Movement Program may be used as a beneficial measure to improve the self-efficacy and writing abilities of children with ADHD tendency accompanied by learning delays. It is necessary to design various intervention models by combining educational media based on a multisensory approach.

A non-replicating oncolytic vector as a novel therapeutic tool against cancer

  • Kaneda, Yasufumi
    • BMB Reports
    • /
    • v.43 no.12
    • /
    • pp.773-780
    • /
    • 2010
  • Cancers are still difficult targets despite recent advances in cancer therapy. Due to the heterogeneity of cancer, a single-treatment modality is insufficient for the complete elimination of cancer cells. Therapeutic strategies from various aspects are needed. Gene therapy has been expected to bring a breakthrough to cancer therapy, but it has not yet been successful. Gene therapy also should be combined with other treatments to enhance multiple therapeutic pathways. In this view, gene delivery vector itself should be equipped with intrinsic anti-cancer activities. HVJ (hemagglutinating virus of Japan; Sendai virus) envelope vector (HVJ-E) was developed to deliver therapeutic molecules. HVJ-E itself possessed anti-tumor activities such as the generation of anti-tumor immunities and the induction of cancer-selective apoptosis. In addition to the intrinsic anti-tumor activities, therapeutic molecules incorporated into HVJ-E enabled to achieve multi-modal therapeutic strategies in cancer treatment. Tumor-targeting HVJ-E was also developed. Thus, HVJ-E will be a novel promising tool for cancer treatment.

Development of Multi-wavelength Laser Medical Therapy Apparatus (다파장 레이저치료기의 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

Two Cases of Disseminated Intravascular Coagulation (DIC) Following Pit Viper Envenomation (살모사 교상 후 발생한 범발성 혈관내 응고장애 2례)

  • Kim, Suk-Hwan;Choi, Se-Min;Oh, Young-Min;Park, Kyu-Nam;Lee, Won-Jae;Choi, Kyung-Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.2
    • /
    • pp.137-142
    • /
    • 2006
  • Our records include two cases of DIC in snakebite patients. One patient, who was 48-years old, was bitten in his left ankle 3 days before admission to our hospital. Initial symptoms were painful swelling, extensive ecchymosis, and persistent bleeding at the bite site. He visited and was admitted to a local hospital, but his condition did not improve with supportive care that included a single dose of antivenin. He was transferred to our hospital. His condition was compatible with DIC. We tried multi-dose antivenin therapy and blood product transfusion. At the seventh hospital day, the patient's symptoms were completely resolved. The other patient, who was 75 years old, was bitten in his right thumb. Initial symptoms were painful swelling of the right arm and persistent bleeding at the bite site, and within minutes of hospital admission, the patient experienced massive hematochezia. We peformed laboratory tests, the results of which were compatible with DIC, and the next day a sigmoidscopic examination showed ischemic colitis. We administered multi-dose antivenin therapy and blood product tranfusion. At the third hospital day mild anemia still existed, but the patient's clinical condition was improved. No signs or symptoms of gastrointestinal bleeding were observed. In these two cases, multi-dose antivenin therapy and transfusion effectively resolved symptoms of DIC. Platelet concentrate transfusion was required only for acute thrombocytopenia. After resolution of DIC, platelet counts were returned to normal ranges within a few days. The authors propose that multidose antivenin therapy and coagulation factor transfusion might be useful for improving coagulopathy in snakebite patients.

  • PDF

Development of a New Radiotherapy Technique using the Quasi-Conformation Method (Quasi-Conformation 치료를 위한 새로운 방사선치료기술의 개발)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.343-350
    • /
    • 1991
  • The quasi-conformation therapy was performed to get a homogeneous dose distributions for irregeular shaped tumor lesion by using the arc moving beam and beam modifying filter which was made by cerrobend alloy($\rho$=9.4 g/cc) metal. In our dose calcuation programme, it was fundmentally based on Clarkson's method to calcuate the irregular multi-step block field in rotation therapy. In this study, the expected relative depth doses under multipartial attenuator agree well with measured data at same plane. The results of comparison the dose computation with that of TLD measurement are very closed within ${\pm}5\%$ uncertainties in the irradiation to phantom with quasi-comformation method. And it has shown that irregular typed multi-step filter can be applied to quasi-conformation therapy in high energy radiation plannings.

  • PDF