• Title/Summary/Keyword: Multi-point measurement

Search Result 182, Processing Time 0.028 seconds

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Monitoring of Internal Harmful Factors According to Environmental Factors in Pig Farm (양돈장 내의 환경 요인에 따른 내부 유해인자의 변동 모니터링)

  • Lee, Seong-Won;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.105-115
    • /
    • 2020
  • With the decrease of the agricultural population in Korea, the workers who is vulnerable to labor are increasing in agricultural industry because of aging, feminization of population. They are exposed in poor working environment with higher temperature and concentrations of dust, gas. Higher concentration of harmful gas and dust can cause chronic and acute disease to workers depending on exposure intensity and frequency. In order to improve the working environment in the livestock facilities, It is important to secure monitoring data of the thermal environment and the concentration of harmful gases and fine dust. Multi-point measurement was performed to analyze the regional environmental conditions in the pig rooms. When analyzing the working environment, video monitoring was conducted to analyze the concentration changes of ammonia, hydrogen sulfide and fine dust according to worker movement and work type. Ammonia and hydrogen sulfide monitoring result showed 1.5~2 times higher concentrations than other work when working in the pigs living zone, and 2~4 times higher than other work when working to increase the activity of pigs. In the case of fine dust, the result was 1.3 times higher than the worker's exposure standard in a specific work. The concentrations of gases and dusts from pig farms are not of concern for acute poisoning in normal work, but there is a risk of chronic respiratory disease if they are continuously exposed. Accordingly, there is a need for development of work environment monitoring device tailored to workers and preparation of alternatives.

Stereo-digital image correlation in the behavior investigation of CFRP-steel composite members

  • Dai, Yun-Tong;Wang, Hai-Tao;Ge, Tian-Yuan;Wu, Gang;Wan, Jian-Xiao;Cao, Shuang-Yin;Yang, Fu-Jun;He, Xiao-Yuan
    • Steel and Composite Structures
    • /
    • v.23 no.6
    • /
    • pp.727-736
    • /
    • 2017
  • The application of carbon fiber reinforced polymer (CFRP) in steel structures primarily includes two categories, i.e., the bond-critical application and the contact-critical application. Debonding failure and buckling failure are the main failure modes for these two applications. Conventional electrometric techniques may not provide precise results because of the limitations associated with single-point contact measurements. A nondestructive full-field measurement technique is a valuable alternative to conventional methods. In this study, the digital image correlation (DIC) technique was adopted to investigate the bond behavior and buckling behavior of CFRP-steel composite members. The CFRP-to-steel bonded joint and the CFRP-strengthened square hollow section (SHS) steel column were tested to verify the suitability of the DIC technique. The stereo-DIC technique was utilized to measure continuous deformation. The bond-slip relationship of the CFRP-to-steel interface was derived using the DIC data. Additionally, a multi-camera DIC system consisting of four stereo-DIC subsystems was proposed and applied to the compressive test of CFRP-strengthened SHS steel column. The precise buckling location and CFRP delamination of the CFRP-strengthened SHS steel column were identified. The experimental results confirm that the stereo-DIC technique can provide effective measurements for investigating the behaviors of CFRP-steel composite members.

An Study on the Optimization of Sub-chamber Geometry in CVC with Sub-chamber (부실을 가진 정적연소기에서 부실형상의 최적화 연구)

  • Park, Jong-Sang;Kang, Byung-Mu;Yeum, Jung-Kuk;Ha, Jong-Yul;Chung, Sung-Sik
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 2005
  • An experimental study was carried out to obtain the fundamental data about the effects of radical ignition on premixture combustion. A CVC(constant volume combustor) divided into the sub-chamber and the main chamber was used. Numerous narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in tile sub-chamber derives the simultaneous multi-point ignition in the main chamber. We have examined the effects of the sub-chamber volume, the diameter and number of passage holes, and the equivalence $ratio({\Phi})$ on the combustion characteristics by means of burning pressure measurement and flame visualization. In a CVC, the overall burning time including the ignition delay became very short and the maximum burning pressure was slightly increased by the radical ignition(RI) method in comparison with those by the conventional spark ignition(SI) method. Combustible lean limit by RI method is extended by ${\Phi}=0.25$ compared with that by SI method. Also, In cases of charging the number and the diameter for the fixed total cross section of the passage holes, combustion period increased significantly at a sub-chamber with a single hole, but those of the other conditions had almost a similar tendency in the sub-chamber with 4 or more holes. regardless of equivalence ratio. Therefore, it was Proved that a critical cross section exists with the number of passage holes.

  • PDF

Electromagnetic Interference Shielding Effectiveness and Mechanical Properties of MWCNT-reinforced Polypropylene Nanocomposites (다중벽 탄소나노튜브강화 폴리프로필렌 나노복합재료의 전자파 차폐효과 및 기계적 특성)

  • Yim, Yoon-Ji;Seo, Min-Kang;Kim, Hak-Yong;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.494-499
    • /
    • 2012
  • In this work, the effect of multi-walled carbon nanotube (MWCNT) on electromagnetic interference shielding effectiveness (EMI SE) and mechanical properties of MWCNT-reinforced polypropylene (PP) nanocomposites were investigated with varying MWCNT content from 1 to 10 wt%. Electric resistance was tested using a 4-point-probe electric resistivity tester. The EMI SE of the nanocomposites was evaluated by means of the reflection and adsorption methods. The mechanical properties of the nanocomposites were studied through the critical stress intensity factor ($K_{IC}$) measurement. The morphologies were observed by scanning electron microscopy (SEM). From the results, it was found that the EMI SE was enhanced with increasing MWCNT content, which played a key factor to determine the EMI SE. The $K_{IC}$ value was increased with increasing MWCNT content, whereas the value decreased above 5 wt% MWCNT content. This was probably considered that the MWCNT entangled with each other in PP due to an excess of MWCNT.

Evaluation of the Degradation of a 1300℃-class Gas Turbine Blade by a Coating Analysis (1300℃급 가스터빈 1단 블레이드의 코팅분석을 이용한 열화평가)

  • Song, Tae Hoon;Chang, Sung Yong;Kim, Beom Soo;Chang, Jung Chel
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.10
    • /
    • pp.901-906
    • /
    • 2010
  • The first stage blade of a gas turbine was operated under a severe environment which included both $1300^{\circ}C$ hot gas and thermal stress. To obtain high efficiency, a thermal barrier coating (TBC) and an internal cooling system were used to increase the firing temperature. The TBC consists of multi-layer coatings of a ceramic outer layer (top coating) and a metallic inner layer (bond coat) between the ceramic and the substrate. The top and bond coating layer respectively act as a thermal barrier against hot gas and a buffer against the thermal stress caused by the difference in the thermal expansion coefficient between the ceramic and the substrate. Particularly, the bondcoating layer improves the resistance against oxidation and corrosion. An inter-diffusion layer is generated between the bond coat and the substrate due to the exposure at a high temperature and the diffusion phenomenon. A thickness measurement result showed that the bond coat of the suction side was thicker than that of the pressure side. The thickest inter-diffusion zone was noted at SS1 (Suction Side point 1). A chemical composition analysis of the bond coat showed aluminum depletion around the inter-diffusion layer. In this study, we evaluated the properties of the bond coat and the degradation of the coating layer used on a $1300^{\circ}C$-class gas turbine blade. Moreover, the operation temperature of the blade was estimated using the Arrhenius equation and this was compared with the result of a thermal analysis.

A comparative study on discharge measurement using multi-point radar surface velocity meter (다회선 표면유속 측정시스템을 이용한 유량측정 비교 연구)

  • Yeong Seon Yun;Sang Uk Cho;Se Hwan Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.369-369
    • /
    • 2023
  • 표면유속계는 비접촉식으로 하천의 유량을 측정하는 방식이기 때문에 효율적이며, 특히 홍수발생시 안전한 측정이 가능하다. 이러한 비접촉식 방식이 갖는 장점으로 인해 홍수기 측정에 표면유속계가 널리 활용되고 있다. 하지만 포인트 방식의 표면유속계의 경우에도 측점마다 측정장비를이동하는 과정에서 어느 정도의 측정시간이 소요되며, 측정 시마다 기본적으로 최소 2~3인의 인력을 필요로 한다. 최근 발생하는 홍수사상은 돌발강우에 의해 발생할 뿐만 아니라 단시간 내에 급격한 수위 및 유량변화가 발생하기 때문에 대응하기 매우 어려우며 특히, 야간에 발생하는 호우사상은 야간측정에 따른 안전 사고가 발생할 우려가 있다. 따라서 본 연구에서는 홍수 시 유량측정에 효율적으로 대응할 수 있는 방안으로 다회선 표면유속계를 이용한 유량측정방법을 실제 하천에 적용하고 표면유속을 이용한 다양한 유량산정방법을 실측결과와의 비교를 통해 적용성을 검토하였다. 표면유속계는 다회선 구성이 가능한 레이다유속계(RQ-30) 5대를 활용하였으며, 금강 본류에 위치한 세종시(햇무리교) 관측소를 대상으로 홍수기 유량측정을 수행하였다. 표면유속을 이용한 유량산정방법으로는 5개 유속계의 측정구간을 합산하는 중간단면적법과 표면유속을 지표로하는 지표유속법을 적용하였으며, 유량산정 결과는 기존 관측소의 수위-유량관계의 환산유량과 ADCP를 이용한 실측유량을 비교하였다. 다회선 표면유속 측정시스템을 이용하여 유량을 산정한 결과, 중간단면적법 및 지표유속법 모두 실측치와의 상대오차가 5% 이내로 비교적 정확한 유량측정이 가능한 것으로 확인되었다. 따라서, 향후 홍수기 유량측정이 어렵거나 위험한 지점을 대상으로 홍수가 주로 발생하는 기간에 일시적으로 설치하여 활용이 가능할 것으로 판단된다.

  • PDF

Improvement and Implementation to Enhance the Effectiveness of the Total Pollution Load Control System (수질오염총량관리제 실효성 제고를 위한 제도개선 및 추진 방향)

  • Seok-Gyu Kim;Seung-Young Oh;Su-Young Park;Eun-Hye Na;Yong-Seok Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.343-355
    • /
    • 2023
  • After the implementation of the total pollution load control system, the effect of improving river water quality by expanding investments in basic environmental facilities, inducing operational efficiency, and reducing the load of various pollutants was clear. However, since the implementation of the system, the management of non-point pollutants has been neglected; management focused on specific substances (biochemical oxygen demand (BOD) and total phosphorus (T-P)) and lacked specific cause analysis and action plans, failed to establish a relationship between water quality and pollution load, failed to reflect stakeholder demands for river water quality management, and failed to apply technical conditions. Therefore, to overcome the limitations raised and achieve a practical and efficient advanced total pollution system, the current system was partially improved and will continue to be improved. This study analyzed the performance and limitations of the total pollution system and introduced recent improvements and the contents that are being improved. The main contents included reducing emissions and reduction monitoring, using water quality tele-monitoring system (TMS) data and self-measurement data, adding population-inducing facilities, and adjusting regional development projects from 20 to 30 multi-family housing units, currentizing each pollutant source according to the roadmap. If the system is improved in a developmental direction and responds to various changes, it will be a more practical and effective policy.

Development of Pump Type Muli-channel Complex Water Quality Sensor for Smart Aqua-farm (스마트 양식장을 위한 유입식 다채널 복합수질센서 시스템 개발)

  • Hong-Pyo Kim;Kyoung-Wook Park;Sung-Keun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.5
    • /
    • pp.983-990
    • /
    • 2024
  • Water quality management is an important element of aquaculture, and digitization of water quality information can be said to be the starting point of smart aquaculture. The complex water quality sensor is an IoT device that automatically measures arrow items such as pH, DO, water temperature, and salinity. However, due to the high price of the water quality sensor, it is economically burdensome to apply it to all aquaculture tanks, and it requires specialized knowledge to maintain them, making it difficult for small-scale aquaculture providers to apply them. In this paper, we propose a multi-channel complex water quality sensor to solve this problem. The proposed system is a device that measures the water quality of multiple tanks with a single sensor through valve control with a pump, thereby reducing sensor purchase costs for fish farms. In addition, we aimed to extend the service life of the sensor and improve the convenience of management by providing an automatic cleaning function using fresh water after measurement.

Manipulation and diagnosis of femtosecond relativistic electron bunch using terahertz-driven resonators

  • Yang Xu;Yifang Song;Cheng-Ying Tsai;Jian Wang;Zhengzheng Liu;Kuanjun Fan;Jinfeng Yang;Oleg Meshkov
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4237-4246
    • /
    • 2024
  • Using strong electromagnetic fields generated by lasers to interact with electrons for precise diagnosis and manipulation of electron beams represents a recent focal point in accelerator technology. This approach surpasses the limitations of conventional RF technology, such as low electric field gradients and timing jitters, effectively enhancing the accuracy of ultrafast electron beam diagnostics and manipulations. As demands for precision continue to rise, the precise diagnosis of crucial parameters of ultrafast electron beams remains challenging. This study delves into the electromagnetic behavior of THz-driven devices and proposes an all-optical method utilizing single-cycle THz radiation to compress and characterize a 3 MeV electron beam. Particle tracking simulations demonstrate an astonishing compression effect, reducing the bunch length from 54.0 fs to 4.3 fs, and achieving sub-femtosecond bunch length measurement resolution. Moreover, when combined with an orthogonal THz streak camera, this method shows even greater potential in multi-bunch scenarios.