• Title/Summary/Keyword: Multi-fault

검색결과 410건 처리시간 0.031초

실 배전계통 자동화를 위한 개선된 고장복구 알고리즘 개발 (Development of Enhanced Real-Time Service Restoration Algorithm for Distribution Automation System)

  • 오화진;문경준;김형수;서정일;황기현;박준호;임성일;하복남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.159-161
    • /
    • 2000
  • This paper presents a GA for service restoration in electric power distribution systems. The aim of the service restoration is to restore service with maximizing the amount of total load restored while minimizing the number of required switch operation when a fault or overload occurs in distribution system. This paper develops GA for service restoration problem with constrained multi-objective optimization problem. The results show the effectiveness of the proposed method for solving the problem.

  • PDF

PCS 환경에서 윈도우 기법을 적용한 새로운 직렬 간섭 제거 기술 (A new interference cancellation applying widowing technique in PCS environment)

  • 도상현;김의묵;최형진
    • 한국통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.2388-2400
    • /
    • 1997
  • 본 논문에서는 PCS환경에서 다중 사용자 간섭의 제거를 위한 직렬 간섭 제거 방식을 분석하고, 이를 개선한 새로운 직렬 간섭 제거 방식을 제안한다. DS/CDMA 통신 시스템에서는 성능 열화의 원인이 되는 원근 효과(near-far effect)와 다중 사용자 간섭(Multi Access Interference)에 대한 보상이 요구되며, 이러한 문제를 보상하는 방법으로 다중 사용자 간섭 제거를 위한 직렬 간섭 제거 기술이 제안된 바 있다. 그러나 이러한 직렬 제거 방식은 사용자간의 간섭 제거 횟수의 가변성으로 인하여 안정된 성능을 보이기가 어렵다. 본 논문에서는 이러한 단점을 개선한 방식으로 윈도우 기법을 적용한 직렬 간섭 제거 방식을 제안하고, 이에 대한 성능 평가를 수행하였다.

  • PDF

Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes

  • Alhan, Cenk;Ozgur, Murat
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1439-1461
    • /
    • 2015
  • Design criteria, modeling rules, and analysis principles of seismic isolation systems have already found place in important building codes and standards such as the Uniform Building Code and ASCE/SEI 7-05. Although real behaviors of isolation systems composed of high damping or lead rubber bearings are nonlinear, equivalent linear models can be obtained using effective stiffness and damping which makes use of linear seismic analysis methods for seismic-isolated buildings possible. However, equivalent linear modeling and analysis may lead to errors in seismic response terms of multi-story buildings and thus need to be assessed comprehensively. This study investigates the accuracy of equivalent linear modeling via numerical experiments conducted on generic five-story three dimensional seismic-isolated buildings. A wide range of nonlinear isolation systems with different characteristics and their equivalent linear counterparts are subjected to historical earthquakes and isolation system displacements, top floor accelerations, story drifts, base shears, and torsional base moments are compared. Relations between the accuracy of the estimates of peak structural responses from equivalent linear models and typical characteristics of nonlinear isolation systems including effective period, rigid-body mode period, effective viscous damping ratio, and post-yield to pre-yield stiffness ratio are established. Influence of biaxial interaction and plan eccentricity are also examined.

오디오믹서용 디지털-아날로그 하이브리드 이중화 시스템 개발 (Development of Digital/Analog Hybrid Redundancy System for Audio Mixer)

  • 김관웅;조주필
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.63-68
    • /
    • 2016
  • 오디오 믹서(audio mixer)는 다수의 오디오 신호의 믹싱을 수행하는 전자장치이다, DSP기술과 IT기술의 발전으로 다양한 기능과 확장성을 가진 디지털 믹서가 시장에 보급되고 있다. 그러나 디지털믹서는 제어를 SW를 통해 수행하기 때문에 디지털 오류 또는 소프트웨어 오류에 대해 기존 아날로그 믹서에 비해 안정성에서 매우 취약하다. 본 논문에서는 이러한 문제점에 대응하기 위해 다채널 디지털 아날로그 하이브리드 믹서 구조와 디지털믹서 기능 고장감지 메커니즘과 고장절체 기술을 제안하고 디지털-아날로그 이중화 구조를 가진 오디오 믹서를 개발하였다. 실험결과 전원상실을 제외한 디지털 믹서의 고장을 120ms내에 감지하고 자동으로 아날로그 믹서 모드로 전환하여 믹서 기능 상실 없이 끊임없는 방송 기능을 제공하였다.

고효율 DC/DC 컨버터용 전류분할과 시분할 스위치 비교 연구 (Comarative Study on Current or Time Sharing Switches for High Efficiency DC/DC Converter)

  • 고성훈;조성필;이수원;이성룡
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.68-75
    • /
    • 2012
  • This paper presents a comparative analysis of the parallel operation of different switches in a DC/DC converter. In high power applications, multi-switch PWM power conditioners may be preferred despite a higher component count, due to the absence of low frequency filters, reduced switching losses and fault tolerance. The paper demonstrates how current sharing (CSH) and time sharing (TSH) lead to the reduction of switching stress in the parallel operation of switches in any converter. The solutions proposed in this study can be applied on different scales to other power conditioners for DC/DC converter systems. Discussions of the concepts, hypotheses and computer simulations are verified by 1 kW experimental results.

ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구 (A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data)

  • 박철원;반우현
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구 (A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique)

  • 박재준;전병훈;김진승;전현구;백관현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

IED를 기반으로 하는 디지털 수배전반의 지적추론기반 운전제어 솔루션 설계 (The Design of Operation and Control Solution with Intelligent Inference Capability for IED based Digital Switchgear Panel)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear-Panel Operation and Control Solution) is designed, which is the intelligent inference based operation and control solution to obtain the safety and reliability of electric power supply in substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES(Bus Reconfiguration Expert System) in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part. The alarm knowledge generation part generates automatically alarm knowledge from DB saves it in alarm knowledge base. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.; Especially, alarm knowledge base includes the knowledge patterns related with fault alarm, the overload alarm and the diagnosis alarm. In order to design the database independently in substation structure, busbar is represented as a connectivity node which makes the more generalized graph theory possible. Finally, DSPOCS is implemented in MS Visual $C^{++}$, MFC, the effectiveness and accuracy of the design is verified by simulation study to the typical distribution substation.

Identity-Based Key Agreement Protocol Employing a Symmetric Balanced Incomplete Block Design

  • Shen, Jian;Moh, Sangman;Chung, Ilyong
    • Journal of Communications and Networks
    • /
    • 제14권6호
    • /
    • pp.682-691
    • /
    • 2012
  • Key agreement protocol is a fundamental protocol in cryptography whereby two or more participants can agree on a common conference key in order to communicate securely among themselves. In this situation, the participants can securely send and receive messages with each other. An adversary not having access to the conference key will not be able to decrypt the messages. In this paper, we propose a novel identity-based authenticated multi user key agreement protocol employing a symmetric balanced incomplete block design. Our protocol is built on elliptic curve cryptography and takes advantage of a kind of bilinear map called Weil pairing. The protocol presented can provide an identification (ID)-based authentication service and resist different key attacks. Furthermore, our protocol is efficient and needs only two rounds for generating a common conference key. It is worth noting that the communication cost for generating a conference key in our protocol is only O($\sqrt{n}$) and the computation cost is only O($nm^2$), where $n$ implies the number of participants and m denotes the extension degree of the finite field $F_{p^m}$. In addition, in order to resist the different key attack from malicious participants, our protocol can be further extended to provide the fault tolerant property.