• 제목/요약/키워드: Multi-channel data acquisition system

검색결과 42건 처리시간 0.022초

스펙트럼 해석방법에 의한 다중찬넬 뇌파의 Topographic Brain Map (Topographic Brain Map of Multi-Channel EEG by Spectrum Analysis Method)

  • 유선국;고한우
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.31-36
    • /
    • 1988
  • A personal computer-based brain map is described which will display a gray scale maps showing the distribution of signals derived from the electrical activity of the brain such as EEG or EP This topographic brain mapping system has a flexibility which describe the electrode number and placement mapping onto any shaped space and generate a brain maps by incoorporated the data acquisition and processing software with conventional EEG machine.

  • PDF

다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작 (Manufacture of Custom IC and System for Multi-channel Biotelemeter)

  • 서희돈;박종대
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

모자이크 패턴 전극 압전 페인트 센서를 이용한 충격 위치 검출 (Impact Localization Using Piezoelectric Paint Sensor with Mosaic Pattern Electrodes)

  • 강상현;강래형
    • 항공우주시스템공학회지
    • /
    • 제13권2호
    • /
    • pp.19-25
    • /
    • 2019
  • 구조물의 충격 위치 검출을 위해 본 연구그룹에서는 압전 페인트 센서를 연구하고 있다. 압전 페인트는 고주파 신호 및 충격에 민감한 특성으로 인하여 충격 감지에 사용할 수 있다. 또한, 압전 페인트 센서는 세라믹 센서가 적용될 수 없는 곡선 또는 복잡한 구조에 코팅될 수 있으며 외부 전원을 필요로 하지 않는다. 충격을 검출하기 위해 모자이크 패턴 전극을 시험편 위에 코팅하였고, 충격 신호는 충격이 발생한 전극부에서 얻을 수 있었다. 보다 더 정확한 충격 위치 검출을 위해서는 전극을 더 많은 부분으로 나누어 해당 전극부로부터 충격 데이터 수집이 필요하다. 본 연구에서는, 데이터 수집을 위하여 가볍고 저렴한 간단한 멀티채널 데이터 수집 시스템을 개발하였다. ARM Cortex-M3의 UART 통신을 이용하여 총 4채널의 데이터를 수집하였다.

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

표면근전도를 이용한 허리근육 평가시스템의 설계에 관한 연구 (A Study on the Design of Low Back Muscle Evaluation System Using Surface EMG)

  • 이태우;고도영;정철기;김인수;강원희;이호용;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권5호
    • /
    • pp.338-347
    • /
    • 2005
  • A computer-based low back muscle evaluation system was designed to simultaneously acquire, process, display, quantify, and correlate electromyographic(EMG) activity with muscle force, and range of motion(ROM) in the lumbar muscle of human. This integrated multi-channel system was designed around notebook PC. Each channel consisted of a time and frequency domain block, and T-F(time-frequency) domain block. The captured data in each channel was used to display and Quantify : raw EMG, histogram, zero crossing, turn, RMS(root mean square), variance, mean, power spectrum, median frequency, mean frequency, wavelet transform, Wigner-Ville distribution, Choi-Williams distribution, and Cohen-Posch distribution. To evaluate the performance of the designed system, the static and dynamic contraction experiments from lumbar(waist) level of human were done. The experiment performed in five subjects, and various parameters were tested and compared. This system could equally well be modified to allow acquisition, processing, and analysis of EMG signals in other studies and applications.

Load Cell Noise 제거를 위한 Digital Load Cell 에 대한 연구 (A study on a digital load cell for the removal of load cell noise)

  • 이영진;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2002
  • Noise reduction and a simplification of a precision measurement system has been performed by changing analog output mode of a load cell into digital output mode. Usually, analog output signal of a few $\mu V$ from a load cell are amplified by amp and acquired by A/D converter. If the distance from a load cell to a DAS(Data Acquisition System) increases, more noise signals are mixed. So, a microprocessor has been integrated into a load cell so that the amplification and A/D conversion of output signals could be done in close proximity to the lode cell for the reduction in mixing of noise. Obtained data from the load cell like this manner are transferred to a computer with digital values(of TTL level). To simplify the configuration of a multi-channel DAS, RS-485 communication system has used for data transfer.

  • PDF

데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구 (A Study on Signal Analysis of the Data Aquisition System for Photosensor)

  • 황인호;유선국
    • 재활복지공학회논문지
    • /
    • 제10권3호
    • /
    • pp.237-242
    • /
    • 2016
  • slip-ring 기술을 가진 spiral CT의 주요 장점으로는 X-ray 튜브의 연속적인 회전에 의해 환자에 대한 정보의 손실 없이 데이터를 연속적으로 획득할 수 있다는 것이다. 또한, X-선량의 인체 흡수의 감소를 위해서, 고시그널 저노이즈 및 빠른 데이터 획득 시간을 갖는 시스템이 요구되어 진다. 본 연구에서, CT 적용을 위해 다채널 포토센서 및 데이터 획득 시스템이 개발되어 졌다. 포토센서의 모듈은 16채널 CdWO4 크리스탈 및 실리콘 베이스의 포토다이오드가 사용되었다. 또한, 포토센서로 부터의 입력 신호에 대한 전기적인 증폭을 위해, 트랜스 임피던스 스위치 인테그레이터가 사용되었다. 스위치 인테그레이터는 CT 적용에 대해 적합한 시그널 밴드와 노이즈 퍼포먼스를 갖고 있다. 데이터 획득과 20 bit ADC 의 컨트롤은 FPGA를 이용하였고, 코딩은 VHDL을 사용하였다. CdWO4 기반의 실리콘 포토센서와 고SNR 및 좁은 시그널 밴드를 가진 증폭단 및 FPGA기반의 디지털 하드웨어는 CT적용 이외에 하드웨어 변경 없이 다른 분야에서도 이용 가능하다.

멀티채널 LiDAR 센서 기반 차량 검출 플랫폼을 위한 효율적인 저전력 신호처리 기법 (Efficiency Low-Power Signal Processing for Multi-Channel LiDAR Sensor-Based Vehicle Detection Platform)

  • 정태원;박대진
    • 한국정보통신학회논문지
    • /
    • 제25권7호
    • /
    • pp.977-985
    • /
    • 2021
  • 자율주행 차량이 주목받게 되면서 LiDAR 센서가 대두되었다. LiDAR 센서는 LASER를 이용하여 범위 내에서 특정 지점까지 측정된 거리 값을 3차원 정보로 제공한다. 3차원 거리 값인 만큼 방대한 데이터를 전송하게 되고, 차량의 메인 프로세서 등에서 다른 데이터와 같이 이를 실시간으로 처리하기에는 무리가 있다. 이러한 이슈를 해결하기 위해 통합처리 시스템을 개발하고자 한다. 시스템은 센서로부터 데이터를 받아 처리하는 client와 각 client로부터 데이터를 취합하여 이를 외부로 전송하는 server 프로세스로 구성된다. 각 프로세스의 데이터 수신 및 처리 방법, 프로세스 구동 방법을 변화시켜가며 시스템의 실시간성 확보를 위한 테스트를 진행하였다. 실험 결과, 4대의 LiDAR 센서로 데이터를 수신 받도록 하였으며, background 나 multi-core processing을 적용하여 프로세스를 동작시켰을 때, 각 client는 약 13.2 ms, server는 약 12.6 ms의 응답시간을 확인할 수 있었다.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Environmental Monitoring System for Base Station with Sensor Node Networks

  • Hur, Chung-Inn;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.258-262
    • /
    • 2009
  • A Practical application of environmental monitoring system based on wireless sensor node network with the core of embedded system STR711FR2 microprocessor is presented in the paper. The adaptable and classifiable wireless sensor node network is used to achieve the data acquisition and multi-hop wireless communication of parameters of the monitoring base station environment including repeaters. The structure of the system is proposed and the hardware architecture of the system is designed, and the system operating procedures is proposed. As a result of field test, designed hardware platform operated with 50kbps bit rate and 5MHz channel spacing at 2040Hz. The wireless monitoring system can be managed and swiftly retreated without support of base station environmental monitoring.