• Title/Summary/Keyword: Multi-Step Inverters

Search Result 7, Processing Time 0.027 seconds

Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors (멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성)

  • Gopakumnr, K.;Ryu, Hong-Je;Kim, Jong-Su;Im, Geun-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

New Double-Connected Multi-Step Inverter for SVC Applications (SVC적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • 양승욱;최세완;문건우;조정구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.547-553
    • /
    • 1999
  • A new multi-step voltage source inverter is proposed in this paper. The proposed scheme is composed of t the double-connected 12-step inverter with an auxiliary circuit. The auxiliary circuit includes two voltage d dividing capacitors, two switching devices and a low KV A autotransformer. The resultant system is shown to b be a 24-step inverter suitable for medium power level SVC applications in which the PWM method can not be e employed. A 36-step operation can also be 이)tained by the addition of a bidirectional switch to the ProlXlsed I inverter. The design parameters are derived from the analysis of voltages and currents by means of switching f functions. The validity of the proposed scheme is confirmed by the simulated and experimental results.

  • PDF

New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • Yang, Seung-Uk;Choe, Gyu-Ha;Mok, Hyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Now, in this paper, going to present you with an Idea related to a new inverter of multi-step voltage source, that Is, the double-connected 12-step inverter with an auxiliary circuit. It possibly can be 24-step inverter with 3-phase voltage source which will enable us make full application even to medium and high power-level Motor drive, UPS, STATCOM, SVC, etc. in which the PWM method could not be employed. 24-step operation can be obtained from the link between the existing 12-step inverter and the additional auxiliary circuit in which the transformer of auxiliary circuit generates ripple voltage delivered to the inverter. Through a lot of experiments and simulations, (from which the validity of this scheme is confirmed,) we came to the conclusion that the increase of the primary winding number on transformer by 2N(N=1,2,3....) leads to the 12M-step(M=2,3,4...) inverter. The validity of the proposed scheme is confirmed by the simulated and experimental results.

Improved Model Predictive Control Method for Cascaded H-Bridge Multilevel Inverters (Cascaded H-Bridge 멀티레벨 인버터를 위한 개선된 모델 예측 제어 방법)

  • Roh, Chan;Kim, Jae-Chang;Kwak, Sangshin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.846-853
    • /
    • 2018
  • In this paper, an improved model predictive control (MPC) method is proposed, which reduces the amount of calculations caused by the increased number of candidate voltage vectors with the increased voltage level in multi-level inverters. When the conventional MPC method is used for multi-level inverters, all candidate voltage vectors are considered to predict the next-step current value. However, in the case that the sampling time is short, increased voltage level makes it difficult to consider the all candidate voltage vectors. In this paper, the improved MPC method which can get a fast transient response is proposed with a small amount of the computation by adding new candidate voltage vectors that are set to find the optimal vector. As a result, the proposed method shows faster transient response than the method that considers the adjacent vectors and reduces the computational burden compared to the method that considers the whole voltage vector. the performance of the proposed method is verified through simulations and experiments.

Design of Test Equipment for LSM Section Switching Test (장계자형 LSM 섹션전환용 시험장치 설계)

  • Jo, Jeong-Min;Han, Young-Jae;Lee, Chang-Young;Cho, Ju-Hyun;Choi, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2383-2388
    • /
    • 2011
  • LSMs are installed under girders along the long track. In order to improve the efficiency of the LSM, long stator LSM should be divided into the specified length and the propulsion inverters should have the system topology to generate high voltage and current for LSMs. This paper presents a system topology with two-step inverter in order to generate high voltage in inverter. A LSM propulsion system is developed and implemented in Maltab/Simulink. A system model of the two-step Inverter is applied to developed model. This paper demonstrates through simulation, advantages of multi-step inverter. The conclusions can serve the design of LSM propulsion system.

  • PDF

System Design for LSM Section Switching Test (LSM 섹션전환시험을 위한 시스템 설계)

  • Jo, Jeong-Min;Han, Young-Jae;Lee, Chang-Young;Shin, Seung-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1258-1259
    • /
    • 2011
  • LSMs are installed under girders along the long track. In order to improve the efficiency of the LSM, long stator LSM should be divided into the specified length and the propulsion inverters should have the system topology to generate high voltage and current for LSMs. This paper presents a system topology with two-step inverter in order to generate high voltage in inverter. A LSM propulsion system is developed and implemented in Maltab/Simulink. A system model of the two-step Inverter is applied to developed model. This paper demonstrates through simulation, advantages of multi-step inverter. The conclusions can serve the design of LSM propulsion system.

  • PDF

Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter (멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF