• Title/Summary/Keyword: Mr studies

Search Result 315, Processing Time 0.025 seconds

Convolutional Neural Network-Based Automatic Segmentation of Substantia Nigra on Nigrosome and Neuromelanin Sensitive MR Images

  • Kang, Junghwa;Kim, Hyeonha;Kim, Eunjin;Kim, Eunbi;Lee, Hyebin;Shin, Na-young;Nam, Yoonho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.156-163
    • /
    • 2021
  • Recently, neuromelanin and nigrosome imaging techniques have been developed to evaluate the substantia nigra in Parkinson's disease. Previous studies have shown potential benefits of quantitative analysis of neuromelanin and nigrosome images in the substantia nigra, although visual assessments have been performed to evaluate structures in most studies. In this study, we investigate the potential of using deep learning based automatic region segmentation techniques for quantitative analysis of the substantia nigra. The deep convolutional neural network was trained to automatically segment substantia nigra regions on 3D nigrosome and neuromelanin sensitive MR images obtained from 30 subjects. With a 5-fold cross-validation, the mean calculated dice similarity coefficient between manual and deep learning was 0.70 ± 0.11. Although calculated dice similarity coefficients were relatively low due to empirically drawn margins, selected slices were overlapped for more than two slices of all subjects. Our results demonstrate that deep convolutional neural network-based method could provide reliable localization of substantia nigra regions on neuromelanin and nigrosome sensitive MR images.

Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT

  • Ji-Hoon Kim;Hyun Kwon Ha;Min Jee Sohn;Byung Suck Shin;Young Suk Lee;Soo Yoon Chung;Pyo Nyun Kim;Moon-Gyu Lee;Yong-Ho Auh
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • Objective: To evaluate the usefulness of MR imaging for diseases of the small intestine, emphasizing a comparison with CT. Materials and Methods: Thirty-four patients who underwent both CT and MR imaging using FLASH 2D and HASTE sequences were analyzed. All patients had various small bowel diseases with variable association of peritoneal lesions. We compared the detectabilities of CT and MR imaging using different MR pulse sequences. The capability for analyzing the characteristics of small intestinal disease was also compared. Results: MR imaging was nearly equal to CT for detecting intraluminal or peritoneal masses, lesions in the bowel and mesentery, and small bowel obstruction, but was definitely inferior for detecting omental lesions. The most successful MR imaging sequence was HASTE for demonstrating bowel wall thickening, coronal FLASH 2D for mesenteric lesions, and axial FLASH 2D for omental lesions. MR imaging yielded greater information than CT in six of 12 inflammatory bowel diseases, while it was equal to CT in six of seven neoplasms and inferior in five of seven mesenteric ischemia. In determining the primary causes of 15 intestinal obstructions, MR imaging was correct in 11 (73%) and CT in nine (60%) patients. Conclusion: MR imaging can serve as an alternative diagnostic tool for patients with suspected inflammatory bowel disease, small intestinal neoplasm or obstruction.

  • PDF

Performance Comparison of Semi-active Control Algorithms for a Large-scale MR Damper using Real-time Hybrid Test Method (실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 준능동 제어알고리즘 성능 비교)

  • Park, Eun-Churn;Lee, Sung-Kyung;Lee, Heon-Jae;Choi, Kang-Min;Moon, Suk-Jun;Jung, Hyung-Jo;Chung, Hee-San;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.648-654
    • /
    • 2007
  • This paper presents the result of a comparison study to evaluate the performance of several semi-active control algorithms for use with large-scale MR damper applied to a building structure under seismic excitation using real-time hybrid test method. Recently, a variety of semi-active control algorithm studies are developed and generally evaluated the performance by using numerical analysis. In this paper real-time hybrid test method was applied to performance evaluating of semi-active control algorithms including a clipped optimal algorithm and the modulated homogeneous friction algorithm.

  • PDF

Production of the Isocyanide Inhibitor of Melanin Biosynthesis by Trichoderma sp. MR-93 (Trichoderma sp. MR-93 균주가 생산하는 Isocyanide 계열의 Melanin 생성 저해물질)

  • Lee, Choong-Hwan;Chun, Hyo-Kon;Chung, Myung-Chul;Lee, Ho-Jae;Bae, Kyung-Sook;Kho, Yung-Hee
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.2
    • /
    • pp.209-213
    • /
    • 1995
  • During the screening of inhibitors of melanin biosynthesis from microbial secondary metabolites, a fungal strain MR-93 which was capable of producing high level of an inhibitor was selected from plant leaf. Based on taxonomic studies, the fungus could be classified as a strain of Trichoderma sp.. The active compound (MR-93D) was purified from the culture broth by Diaion HP-20 column chromatography, ethylacetate extraction, Sephadex LH-20 column chromatography and HPLC. The inhibitor was identified as 4-hydroxy-8-isocyano-l-oxaspiro[4-4]cyclonon-8-en-2- one by spectroscopic methods of UV, $^{1}$H-NMR, ESIMS and IR. MR-93D showed a strong tyrosinase inhibitory activity with 0.03 $\mu$g/m of IC$_{50}$ value. It also inhibited melanin biosynthesis with 35 mm inhibition zone at 30 $\mu$g/paper disc in Streptomyces bikiniensis, a bacterium used as an indicator organism in this work.

  • PDF

Capacity and Placement of MR Damper for Vibration Control of MDOF System (다자유도 시스템의 진동제어를 위한 MR감소기 용량 및 위치 선정)

  • 이상현;민경원;이루지;김대곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, peliminary design procedure of magnetorheological (MR) dampers is developed for controlling the building response induced by seismic excitation. Hysteretic biviscous model which is simple and can describe the hysteretic characteristics of MR damper is used for parametric studies. The capacity of MR damper is determined as a portion of not the building weight but the lateral restoring force. A method is proposed for the optimal placement and number of MR dampers, and its effectiveness is verified by comparing it with the simplified search algorithm. Numerical results indicate that the capacity, number and the placement can be reasonably determined using the proposed design procedure.

  • PDF

Performance verification of Smart Complex Damping System for Suppressing Vibration of Stay Cable (케이블 진동 저감을 위한 스마트 복합 감쇠 시스템의 성능평가)

  • Park, Chul-Min;Jung, Hyung-Jo;Ko, Man-Gi;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.453-460
    • /
    • 2006
  • Stay cables, such as used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Recently some studies have shown that active and semiactive control system using MR damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart complex damping system which consists of toggle system and MR dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. The performance of the proposed damping device has been compared with that of the passive-type control systems employing a MR damper, a linear viscous damper, and EMI system.

  • PDF

Localized Proton MR Spectroscopic Detection of Nonketotic Hyperglycinemia in an Infant

  • Choong-Gon Choi;Ho Kyu Lee;Jong-Hyun Yoon
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.239-242
    • /
    • 2001
  • Nonketotic hyperglycinemia (NKH) is a rare metabolic brain disease caused by deficient activity of the glycine cleveage system. Localized proton MR spectroscopy (echo-time 166 msec), performed in an infant with the typical clinical and biochemical features of neonatal NKH, showed a markedly increased peak intensity at 3.55 ppm, which was assigned to glycine. Serial proton MR spectrosocpic studies indicated that glycine/choline and glycine/total creatine ratios correlated closely with the patient's clinical course. Proton MR spectroscopy was useful for the non-invasive detection and monitoring of cerebral glycine levels in this infant with NKH.

  • PDF

Postcontrast T1-weighted Brain MR Imaging in Children: Comparison of Fat-suppressed Imaging with Conventional or Magnetization Transfer Imaging

  • 이충욱;구현우;최충곤
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.37-37
    • /
    • 2003
  • To assess the merits and demerits of postcontrast fat-suppressed (FS) brain MR imaging in children in the evaluation of various enhancing lesions, compared with postcontrast conventional or Magnetization Transfer (MT) imaging. 대상 및 방법: We reviewed patients with enhancing lesion on brain MR imaging who underwent both FS imaging and one of conventional or MT imaging as a postcontrast T1-weighted brain MR imaging. Inclusion criteria of our study were as follows: MR studies should be peformed within one-year interval and showed no significant interval change of imaging findings. Thirty-four patients (21 male, 13 female; mean age, 8 years) with 43 enhancing lesions (19 intra-axial, 19 extra-axial, and 5 orbital location) were included in this study, Twenty-one pairs of FS and conventional imaging, and 15 pairs of FS and MT imaging were available. Two radiologists visually assessed the lesion conspicuity and the presence of flow or susceptibility artifacts in a total of 36 pairs of MR imaging by consensus. For 21 measurable lesions (19 pairs of FS and conventional imaging, 5 pairs of FS and MR imaging), contrast ratio between the lesion and the normal brain( [SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared.

  • PDF

Blood-Brain Barrier Experiments with Clinical Magnetic Resonance Imaging and an Immunohistochemical Study

  • Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.203-209
    • /
    • 2010
  • Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.

A study on material removal characteristics of MR fluid jet polishing system through flow analysis (유동해석을 통한 MR fluid jet polishing 시스템의 재료제거 특성 분석)

  • Sin, Bong-Cheol;Lim, Dong-Wook;Lee, Jung-Won
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.12-18
    • /
    • 2019
  • Fluid jet polishing is a method of jetting a fluid to polish a concave or free-form surface. However, the fluid jet method is difficult to form a stable polishing spot because of the lack of concentration. In order to solve this problem, MR fluid jet polishing system using an abrasive mixed with an MR fluid whose viscosity changes according to the intensity of a magnetic field is under study. MR fluid jet polishing is not easy to formulate for precise optimal conditions and material removal due to numerous fluid compositions and process conditions. Therefore, in this paper, quantitative data on the factors that have significant influence on the machining conditions are presented using various simulations and the correlation studies are conducted. In order to verify applicability of the fabricated MR fluid jet polishing system by nozzle diameter, the flow pattern and velocity distribution of MR fluid and polishing slurry of MR fluid jet polishing were analyzed by flow analysis and shear stress due to magnetic field changes was analyzed. The MR fluid of the MR fluid jet polishing and the flow pattern and velocity distribution of the polishing slurry were analyzed according to the nozzle diameter and the effects of nozzle diameter on the polishing effect were discussed. The analysis showed that the maximum shear stress was 0.45 mm at the diameter of 0.5 mm, 0.73 mm at 1.0 mm, and 1.24 mm at 1.5 mm. The cross-sectional shape is symmetrical and smooth W-shape is generated, which is consistent with typical fluid spray polishing result. Therefore, it was confirmed that the high-quality surface polishing process can be stably performed using the developed system.