Proceedings of the Computational Structural Engineering Institute Conference (한국전산구조공학회:학술대회논문집)
- 2004.10a
- /
- Pages.34-40
- /
- 2004
Capacity and Placement of MR Damper for Vibration Control of MDOF System
다자유도 시스템의 진동제어를 위한 MR감소기 용량 및 위치 선정
Abstract
In this paper, peliminary design procedure of magnetorheological (MR) dampers is developed for controlling the building response induced by seismic excitation. Hysteretic biviscous model which is simple and can describe the hysteretic characteristics of MR damper is used for parametric studies. The capacity of MR damper is determined as a portion of not the building weight but the lateral restoring force. A method is proposed for the optimal placement and number of MR dampers, and its effectiveness is verified by comparing it with the simplified search algorithm. Numerical results indicate that the capacity, number and the placement can be reasonably determined using the proposed design procedure.
Keywords