• Title/Summary/Keyword: Movement plane

Search Result 380, Processing Time 0.026 seconds

HORIZONTAL PLANE JAW MOVEMENTS IN EDENTULOUS PATIENTS BY USE OF EXTRAORAL TRACING DEVICE (구외 묘기장치를 이용한 무치악 환자의 수평면상 하악운동에 관한 연구)

  • Eun Seong-Sik;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.396-410
    • /
    • 1994
  • Ten subjects who were going to wear conventional complete dentures were selected for this study. Theree subjects were women and seven were men. The average age was 63.1 years(range : 44 to 76 years). With the Height tracer (extraoral tracing device) in place the subject was instructed to go through the entire range of mandibular movements. The extreme lateral pathway of the incisor point, the so-called Gothic arch, was thereby inscribed by the stylus on the tracing plate. The mandibular movements in this study were peformed voluntarily by the subject(self guided technique) and guided by the dentist(chin-point technique and bimanual technique). The Gothic arch tracings were analysed and the Gothic arch angles and eccentric movement distances were measured. The results were as follows : 1. The apex position of the Gothic arch tracings of mandibular movements in edentulous patients varied both anterioposteriorly and mediolaterally. 2. The Gothic arch tracing had some lateral deviation during protrusion. 3. The average Gothic arch tracing angle was $136.7{\pm}12.0^{\circ}$ by subjects self guided technique, $135.7{\pm}5.9^{\circ}$ by chin-point technique, $136.6{\pm}6.5^{\circ}$ by bimanual technique. But there were no statistical differences in the reliability among the three techniques. 4. The average mandibular eccentric movements were irregular and the mandibular eccentric movement distances varied with a wide range.

  • PDF

Expressed Follow Pan's real expression study in a long piece Japanese Animation (일본 장편 애니메이션 작품에 표현된 Follow Pan의 실재감 표현연구)

  • Kim Jea-Ho
    • Journal of Science of Art and Design
    • /
    • v.8
    • /
    • pp.45-61
    • /
    • 2005
  • The 2D animation screen is a screen work that is produced on the plane. So, it is superficial in terms of space. Therefore, we expressed via picture technique that uses the movement of camera and back-ground in order to recreate the image of realistic feeling that has multiple effect. Though all multiple-effects were expressed realistically in the early Disney animation of the United States, Japan used the expression of Follow Pan profoundly to provide the animation with economic expression of picture and the depthof screen in order to realize a new technical expression of limited animation while it was producing TV series works in 1960s. Now it is positively expressed even in the United States, too. This study tries to analyze the example that applied the long piece works of Japan which was expressed via the Follow Pan, that is, the movement of camera, to the real approach.

  • PDF

Precision Analysis of the Depth Measurement System Using a Single Camera with a Rotating Mirror (회전 평면경과 단일 카메라를 이용한 거리측정 시스템의 정밀도 분석)

  • ;;;Chun Shin Lin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.11
    • /
    • pp.626-633
    • /
    • 2003
  • Theoretical analysis of the depth measurement system with the use of a single camera and a rotating mirror has been done. A camera in front of a rotating mirror acquires a sequence of reflected images, from which depth information is extracted. For an object point at a longer distance, the corresponding pixel in the sequence of images moves at a higher speed. Depth measurement based on such pixel movement is investigated. Since the mirror rotates along an axis that is in parallel with the vertical axis of the image plane, the image of an object will only move horizontally. This eases the task of finding corresponding image points. In this paper, the principle of the depth measurement-based on the relation of the pixel movement speed and the depth of objects have been investigated. Also, necessary mathematics to implement the technique is derived and presented. The factors affecting the measurement precision have been studied. Analysis shows that the measurement error increases with the increase of depth. The rotational angle of the mirror between two image-takings also affects the measurement precision. Experimental results using the real camera-mirror setup are reported.

Real-Time Correction of Movement Errors of Machine Axis by Twyman-Green Interferometry (광위상 간섭을 이용한 이송축의 운동오차 실시간 보상)

  • 이형석;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3115-3123
    • /
    • 1993
  • This paper presents a real-time correction method of the movemont errors of a translatory precision machine axis. This method is a null-balances technique in which two plane mirrors are used to generate an interferometric fringe pattern utilizing the optical principles of TwymanGreen interferometry. One mirror is fixed on a reference frame, while the other is placed on the machine axis being supported by three piezoelectric actuators. From the fringe pattern, one translatory and two rotational error components of the machine axis are simultaneously detected by using CCD camera vision and image processing techniques. These errors are then independently suppressed by activating the peizoelectric actuators by real-time feedback control while the machine axis is moving. Experimental results demonstrate that a machine axis can be controlled with movement errors less than 10 nm in vertical straightness, 0.1 arcsec in pitch, and 0.06 arcsec in roll for 50mm travel by adopting the real-time correction method.

Dynamic characteristics between waves and a floating cylindrical body connected to a tension-leg mooring cable placed in a simulated offshore environment

  • Song, Juhun;So, Soo-Hyun;Lim, Hee-Chang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.375-385
    • /
    • 2016
  • Given the rapid progress made in understanding the dynamics of an offshore floating body in an ocean environment, the present study aimed to simulate ocean waves in a small-sized wave flume and to observe the motion of a cylindrical floating body placed in an offshore environment. To generate regular ocean waves in a wave flume, we combined a wave generator and a wave absorber. In addition, to precisely visualise the oscillation of the body, a set of light-emitting diode illuminators and a high-speed charge-coupled device camera were installed in the flume. This study also focuses on the spectral analysis of the movement of the floating body. The wave generator and absorbers worked well to simulate stable regular waves. In addition, the simulated waves agreed well with the plane waves predicted by shallow-water theory. As the period of the oncoming waves changed, the movement of the floating body was substantially different when tethered to a tension-leg mooring cable. In particular, when connected to the tension-leg mooring cable, the natural frequency of the floating body appeared suddenly at 0.391 Hz as the wave period increased.

Optimum Blind Control Considering Characteristics of Solar Profile Angle Curve (건물에서 태양 프로파일의 변화 특성을 고려한 블라인드 최적 제어 방안)

  • Seong, Yoon-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.111-124
    • /
    • 2011
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight by opening/closing of a blind. In previous researches on blind controls, major problem is that the time interval and amount of blind movement do not meet the control objective at the inflected zone of solar profile curve. To overcome these limitations revealed in theprevious researches, following tasks were performed in this study. i)To establish the control objective to accomplish the goal of this study. ii)To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various solar profile angle curves. This study proposed the control strategy and method that define the base control section implying the inflection point within the control objective zone and subsequently, divide the control sections for the residual time zones. The proposed strategy and method are found to increase the incoming daylight and solar irradiation by 0 to 15 %.

Interaction Augmented Reality System using a Hand Motion (손동작을 이용한 상호작용 증강현실 시스템)

  • Choi, Kwang-Woon;Jung, Da-Un;Lee, Suk-Han;Choi, Jong-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.425-438
    • /
    • 2012
  • In this paper, We propose Augmented Reality (AR) System for the interaction between user's hand motion and virtual object motion based on computer vision. The previous AR system provides inconvenience to user because the users have to control the marker and the sensor like a tracker. We solved the problem through hand motion and provide the convenience to the user. Also the motion of virtual object using a physical phenomenon gives a reality. The proposed system obtains geometrical information by the marker and hand. The system environments like virtual space of moving virtual ball and bricks are made by using the geometrical information and user's hand motion is obtained from the hand's information with extracted feature point through the taping hand. And it registers a virtual plane stably by getting movement of the feature points. The movement of the virtual ball basically is parabolic motion with a parabolic equation. When the collision occurs either the planes or the bricks, we show movement of the virtual ball with ball position and normal vector of plane and the ball position is faulted. So we showed corrected ball position through experiment. and we proved that this system can replaced the marker system to compare to jitter of augmented virtual object and progress speed with it.

A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ (악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

Responses of Inferior Olive Neurons to Stimulation of Semicircular Canals. II. Vertical Semicircular Canalss

  • Park, Sah-Hoon;Park, Jong-Seong;Park, Jin-Soon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.4
    • /
    • pp.193-198
    • /
    • 2003
  • In the present study, the vestibularly evoked activity of inferior olive (IO) neurons was examined to investigate the vertical vestibular information transmitted through the vestibulo-olivo-cerebellar climbing fiber pathway. The extracellular recording was made in 74 neurons of the IO of cats, while animals were sinusoidally rotated. Most of vestibularly activated IO neurons responded to the vertical rotation (roll) test and were found in or near the ${\beta}$ subnuclei $(IO{\beta})$. The vestibular IO neurons were activated, when the animal was rotated to the side contralateral to the recording site. In contrast to the observation that the gain of responses of yaw sensitive cells (YSC) was not changed by the rotation frequency, that of the roll-sensitive cells (RSC) decreased as the rotation frequency was increased. Regardless of RSC or HSC, IO neurons showed the tendency of phase-lag in their responses. The alternating excitatory and inhibitory phases of responses of RSC were dependent on the direction of head orientation, the characteristics of which are the null response plane (NRP) and the optimal response plane (ORP). The analysis based on the NRP of RSC showed that vestibular inputs from the ipsilateral anterior semicircular canal induced the NRP of the RSC response at about 45 degree counterclockwise to the longitudinal axis of the animal, and that those inputs were distributed to RSC in the rostral part of $IO{\beta}$. On the other hand, those from the posterior semicircular canal were related with the NRP at about 45 degree clockwise and with the caudal part of the $IO{\beta}$. These results suggest that IO neurons receive and encode the vestibular information, the priority of which seems to be the vertical component of the body movement rather than the horizontal ones.

Development of Mandibular Movements Measuring System Using Double Stereo-Cameras

  • Park, Soon-Yong;Park, Sung-Kee;Cho, Chang-Hyun;Kim, Mun-Sang;Park, Mi-Gnon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1183-1188
    • /
    • 2005
  • In this paper, we propose a 3D automated measuring system which measures the mandibular movements and the reference plane of the jaw movements. In diagnosis and treatment of the malocclusions, it is necessary to estimate the mandibular movements and the reference plane of the jaw movements. The proposed system is configured with double stereo-cameras, PC, two moving pattern plates(MPPs), two fixed pattern plates(FPPs) and one orbital marker. The virtual pattern plate is applied to calculate the homogeneous transformation matrices which describe the coordinates systems of the FPP and MPP with respect to the world coordinates system. To estimate the parameters of the hinge axis, the Euler's theorem is applied. The hinge axis points are intersections between the FPPs and the hinge axis. The coordinates of a hinge axis point with respect to the MPP coordinates system are set up to fixed value. And then, the paths of the jaw movement can be calculated by applying the homogeneous transformation matrix to fixed hinge axis point. To examine the accuracy of the measurements, experiments of measuring the hinge axis points and floating paths of them are performed using the jaw motion simulator. As results, the measurement errors of the hinge axis points are within reasonable boundary, and the floating paths are very similar to the simulator's moving path.

  • PDF