• Title/Summary/Keyword: Motion time

Search Result 5,265, Processing Time 0.029 seconds

Effects of Composite Couplings on Hub Loads of Hingeless Rotor Blade (무힌지 로터 블레이드의 허브하중에 대한 복합재료 연성거동 연구)

  • Lee, Ju-Young;Jung, Sung-Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.29-36
    • /
    • 2004
  • In this work, the effect of composite couplings on hub loads of a hingeless rotor in forward flight is investigated. The hingeless composite rotor blade is idealized as a laminated thin-walled box-beam. The nonclassical effects such as transverse shear, torsional warping are considered in the structural formulation. The nonlinear differential equations of motion are obtained by applying Hamilton's principle. The blade response and hub loads are calculated using a finite element formulation in space and time. The aerodynamic forces acting on the blade are calculated by quasi-steady strip theory. The theory includes the effects of reversed flow and compressibility. The magnitude of elastic couplings obtained by MSC/NASTRAN is compared with the classical pitch-flap $({\delta}3)$ or $pitch-lag({\alpha}1)$ coupling. It is found that the elastic couplings have a substantial effect on the behavior of $N_b/rev$ hub loads. Nearly 10 to 40% of hub loads is reduced by appropriately tailoring the fiber orientation angles in the laminae of the composite blade.

MPEG-7 Texture Descriptor (MPEG-7 질감 기술자)

  • 강호경;정용주;유기원;노용만;김문철;김진웅
    • Journal of Broadcast Engineering
    • /
    • v.5 no.1
    • /
    • pp.10-22
    • /
    • 2000
  • In this paper, we present a texture description method as a standardization of multimedia contents description. Like color, shape, object and camera motion information, texture is one of very important information in the visual part of international standard (MPEG-7) in multimedia contents description. Current MPEG-7 texture descriptor has been designed to fit human visual system. Many psychophysical experiments give evidence that the brain decomposes the spectra into perceptual channels that are bands in spatial frequency. The MPEG-7 texture description method has employed Radon transform that fits with HVS behavior. By taking average energy and energy deviation of HVS channels, the texture descriptor is generated. To test the performance of current texture descriptor, experiments with MPEG-7 Texture data sets of T1 to T7 are performed. Results show that the current MPEG-7 texture descriptor gives better retrieval rate and fast and fast extraction time for texture feature.

  • PDF

Aeroelastic Analysis of Rotorcraft in Forward Flight Using Dynamic Inflow Model (동적 유입류 모델을 이용한 회전익기 전진비행 공탄성 해석)

  • Lee, Joon-Bae;Yoo, Seung-Jae;Jeong, Min-Soo;Lee, In;Kim, Deog-Kwan;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.4
    • /
    • pp.297-305
    • /
    • 2011
  • In this study, the aeroelastic analysis of rotorcraft in forward flight has been performed using dynamic inflow model to handle unsteady aerodynamics. The quasi-steady airload model based on the blade element method has been coupled with dynamic inflow model developed by Peters and He. The nonlinear steady response to periodic motion is obtained by integrating the full finite element equation in time through a coupled trim procedure with a vehicle trim for stability analysis. The aerodynamic and structural characteristics of dynamic inflow model are validated against other numerical analysis results by comparing induced inflow and blade tip deflections(flap, lag). In order to validate aeroelastic stability of dynamic inflow model, lag damping are also compared with those of linear inflow model.

Clinical and Structural Outcomes of Arthroscopic Intraarticular Knotless Fixation for Upper Subscapularis Tendon Tears: A Preliminary Report

  • Cho, Nam Su;Shim, Hee Seok;Nam, Ju Hyun;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.130-136
    • /
    • 2016
  • Background: A novel technique for the repair of tears of the upper subscapularis tendon-intraarticular knotless fixation-has been introduced recently. The purpose of this study was to evaluate the clinical and structural outcomes of arthroscopic intraarticular knotless fixation for the treatment of upper subscapularis tendon tears. Methods: We retrospectively analyzed the clinical and radiological outcomes of 27 patients who underwent arthroscopic intraarticular knotless fixation for upper subscapularis tendon tears. Finally, a total of 10 patients who could participate in at least a 6 month follow-up of magnetic resonance imaging evaluation and in a least 1-year follow-up on an outpatient basis were enrolled in our study. The mean age at the time of operation was 60.7 years, and the mean duration of follow-up was 14.7 months. Two patients had concomitant tears of the supraspinatus tendon and 8 patients had concomitant tears of the supraspinatus and the infraspinatus tendons. Results: The clinical and radiological outcomes improved after the patients had undertaken arthroscopic intraarticular knotless fixation. The mean visual analogue scale score for pain during motion improved from 6.7 preoperatively to 1.4 at the final follow-up (p<0.001). The mean Constant score improved from 59.3 preoperatively to 79.6 at the final follow-up, and the mean the University of California at Los Angeles score, from 21.7 to 30.2, respectively (p<0.001 and p<0.001). The upper subscapularis tendon tear was healed in every patient except one (90%), for the patient had suffered from a postoperative trauma that resulted in a retear. Conclusions: We found that arthroscopic intraarticular knotless fixation gives good clinical and structural outcomes for the repair of upper subscapularis tendon tears. Arthroscopic intraarticular knotless fixation provided such a reliable and efficient restoration of the subscapularis tendon footprint that we anticipate it will become a widely-used procedure for upper subscapularis tendon tears.

Indirect Reduction Technique in Proximal Humeral Fractures Stabilized by Locking Plates

  • Rhee, Yong Girl;Cho, Nam Su;Cha, Sang Won;Moon, Seong Cheol;Hwang, Sang Phil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.2-9
    • /
    • 2014
  • Background: Indirect reduction technique offers a valid option in the treatment of proximal humerus fracture. The purpose of this study is to evaluate the functional outcome and the complication rate after indirect reduction and internal fixation of unstable proximal humeral fractures with use of a locking plate. Methods: Twenty four patients with acute proximal humerus fracture were managed with indirect reduction and internal fixation with a locking plate. The mean follow-up period was 15.5 months. Results: The anatomical reduction of the medial cortex buttress was seen in 16 patients (66%) of the Group A and the non-anatomical reduction was seen in 8 patients (33%) of the Group B. Mean union time was $3.2{\pm}1.9$ months; it was $2.2{\pm}0.6$ months in the Group A and $5.3{\pm}2.2$ months in the Group B (p < 0.05). In our series, there were 6 cases of complications and these include 2 cases of varus malunion, 2 cases of shoulder stiffness, 1 case of heterotrophic ossification, 2 cases of screw perforation and 1 case of impingement. Conclusions: We conclude from our studies that indirect reduction and internal fixation using locking plate for acute proximal humerus fracture can give good results with bony union and predictable good overall functional outcome. If the medial cortex buttress is well maintained, a better anatomical reduction would be achieved, the union would be prompted, the pain would be further reduced and the range of the motion would be recovered more promptly.

Efficacy of the Subclavian Portal Approach in Arthroscopic Repair of Isolated Subscapularis Tendon Tear

  • Chae, Seung Bum;Choi, Chang Hyuk;Jung, Suk-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2014
  • Background: To evaluate the efficacy of the subclavian portal approach for the arthroscopic repair of isolated subscapularis tendon tear. Methods: We used the subclavian portal to carry out arthroscopic repair of the isolated subscapularis tendon tear. The surgery was carried out in 18 cases (average age of 53) from May 2006 to December 2009 with a mean follow-up period of 35 months. Of these cases, 13 patients had the tear in their dominant arms, 16 were male, and 12 were from traumatic ruptures with on average 7.6 months of symptom period to operation. Additional surgery, acromioplasty and subacromial debridement, were carried out on 4 cases each during the subscapularis repair. The integrity of cuff status was assessed by ultrasonographic examination at 6 months and at 1 year after operation. Results: The initial average range of motion in forward flexion, external rotation, and internal rotation were $160^{\circ}$, $50^{\circ}$ and L4, respectively. At the 1 year follow-up period, these improved to $160^{\circ}$, $52^{\circ}$ and T12, respectively. The initial average functional scores were assessed by KSS, ASES, UCLA, and Constant scoring systems, which were 67, 60, 26, and 65, respectively. These scores improved progressively with time. At 3 months after operation, the scores were 74, 67, 27, and 74; at 6 months, 83, 77, 31, and 75; at 1 year, 88, 86, 32, and 79; and at the final follow-up of 35 months, 84, 92, 34, and 84. Conclusions: In the repair of isolated subscapularis tendon tear, the subclavian portal approach provided a good angle for anchor insertion and sufficient space to manage the upper portion of the tendon tear. In turn, these provisions resulted in satisfactory clinical results.

의료용재료의 최근 개발현황

  • 김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 1989
  • The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan`s method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements.

  • PDF

Long-term Follow-up of Reconstruction of the Hand with a Temporoparietal Fascial Free Flap (측두두정근막 자유피판술을 이용한 수부재건의 장기추적조사)

  • Yoon, Do-Won;Kim, Jiye;Yang, Eun Jung;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2013
  • Purpose: Soft tissue defect of the hand, which cannot be covered with skin graft or local flap, is usually reconstructed using a free flap. Temporoparietal fascial free flap is one of the best alternatives for functional reconstruction of the hand with exposed tendons, bones, and joints. Materials and Methods: We have experienced four cases of reconstruction using a temporoparietal fascial flap with a skin graft and followed up for 20 years. We conducted a retrospective review of the patients' clinical charts and photos. Results: At the time of initial injury, the average age of patients was 50.3 (39~62) years. The radial artery was used for reconstruction of the dorsal side of the hand, whereas the ulnar artery was used for that of the volar side of the wrist. Short term complication such as skin graft loss and donor site alopecia occurred. However, during the long term follow-up period, no change of flap volume was noted, and full range of motion in the adjacent joint was maintained. In addition, hyperpigmentation of the grafted skin on the flap disappeared gradually. Conclusion: Selection of the optimal flap is important for reconstruction of the hand without functional limitation. We obtained satisfactory soft tissue coverage and functional outcomes using a temporoparietal fascial free flap and followed up for 20 years.

  • PDF

A study on Power Quality Recognition System using Wavelet Transformation and Neural Networks (웨이블릿 변환과 신경회로망을 이용한 전력 품질 인식 시스템에 관한 연구)

  • Chong, Won-Yong;Gwon, Jin-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • Nonstationary power quality(PQ) signals which the Sag, Swell, Impulsive Transients, and Harmonics make sometimes the operations of the industrial power electronics equipment, speed and motion controller, plant process control systems in the undesired environments. So, this PQ problem might be critical issues between power suppliers and consumers. Therefore, We have studied the PQ recognition system in order to acquire, analyze, and recognize the PQ signals using the software, i.e, MATLAB, Simulink, and CCS, and the hardware. i.e., TMS320C6713DSK(TI), The algorithms of the PQ recognition system in the Wavelet transforms and Backpropagation algorithms of the neural networks. Also, in order to verify the real-time performances of the PQ recognition system under the environments of software and hardware systems, SIL(Software In the Loop) and PIL(Processor In the Loop) were carried out, resulting in the excellent recognition performances of average 99%.

LightSpeed and SimpliFil : Designed for Successful Endodontics

  • Senia, Steve
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.259-259
    • /
    • 2001
  • ;A new root canal instrument and instrumentation technique: a preliminary report. Cleaning and shaping the root canal system has been and continues to be a challenge for even the most experienced endodontist. Curved. narrow canals. in particular. cause difficulties for the beginner as well as the specialist. A new instrument designed to incorporate new concepts was developed to ameliorate the problems in cleaning and shaping root canal systems. This new instrument has been given the name of SW (Senia and Wildey). The new SW instrument uses controlled right and left rotational forces. This motion was used to clean and shape simulated root canals in plastic blocks and root canals in extracted teeth. Instrumentation appeared to be easier. faster. and more precise than with conventional instruments. especially in curved canals where there was remarkable reduction of canal transportation. A mechanical version of the SW instrument was also developed. It was used to flare the coronal portion of the root canal system. Wildey WL. Senia ES., Oral Surg Oral Med Oral Pathol1989 Feb:67(2):198-207 Another look at root canal instrumentation. Several aspects of root canal instrumentation need additional research. Various factors must be considered in an analysis of instrumentation of the root canal system: the dentin that is cut: the technique used to cut it: the design of the instruments: the material and manufacturing process used to make the instruments: the irrigant used during the procedure: and the anatomic configuration of the root canal system. An analysis of these factors clearly indicates that existing root canal instruments and techniques are less than ideal and. in fact. do not accomplish what is expected of them. Root canals must be properly. but. at the same time. destructive and unnecessary removal of dentin should be kept to a minimum. The Flex-R and Canal Master instruments were developed to address some of the shortcomings of existing instruments and techniques. More scientifically based research is needed to fully evaluate these new instruments and techniques and to develop future instruments. Wildey WL; Senia ES. Montgomery S., Oral Surg Oral Med Oral Pathol1992 Oct:74(4):499-50799-507

  • PDF