• Title/Summary/Keyword: Motion monitoring system

Search Result 288, Processing Time 0.028 seconds

A Study on the Implementation of the Web-Camera System for Realtime Monitoring (실시간 영상 감시를 위한 웹 카메라 시스템의 구현에 관한 연구)

  • Ahn, Young-Min;Jin, Hyun-Joon;Park, Nho-Kyung
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.174-181
    • /
    • 2001
  • In this study, the architecture of the Web Camera System for realtime monitoring on Internet is proposed and implemented in two different structures. In the one architecture, a Web-server and a Camera-server are implemented on the same system, and the system transfers motion pictures compressed to JPEG file to users on the WWW(World Wide Web). In the other architecture, the Web-server and the Camera-server are implemented on different systems, and the motion pictures are transferred from the Camera-server to the Web-server, and finally to users. For JPEG image transferring in the Web Camera system, the Java Applet and the Java Script are used to maximize flexibility of the system from the Operating system and the Web browsers. In order to compare system performance between two architectures, data traffic is measured and simulated in the unit of byte per second.

  • PDF

Feasibility of the Depth Camera-based Physical Health Monitoring System for Elderly Living Alone

  • Sungbae, Jo
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.106-112
    • /
    • 2024
  • Objective: This study aimed to evaluate the validity of a depth camera-based system for monitoring physical function, assessing its feasibility for accurately monitoring activities of daily living. Design: A cross-sectional study. Methods: Twenty-three participants were enlisted to perform fifteen activities of daily living within a living laboratory designed to simulate a home environment. Activities were monitored using a depth camera system capable of classifying actions into standing, sitting, and lying down, with a conventional video camera employed for activity recording. The duration of each activity, as measured by the system, was compared to direct observations made by a physical therapist which were analyzed using a motion analysis software. The association between these two measurement approaches was assessed through correlation analysis, coefficient of determination, intraclass correlation coefficient (ICC), and Bland-Altman plots. Results: Our findings indicated that standing activities exhibited the highest correlation (r=0.847) between the system measurements and physical therapist observations, followed by sitting (r=0.817) and lying down (r=0.734), which demonstrated lower correlations. However, the ICC and Bland-Altman plots revealed notable variances between the two measurement methods, particularly for activities involving lying down. Conclusions: In this study, the depth camera-based physical monitoring system showed promise feasibility in distinguishing standing, sitting, and lying down activities at home environments. However, the current study also underlined some necessities of enhancements in capturing lying down activities.

Smart Remote Rehabilitation System Based on the Measurement of Heart Rate from ECG Sensor and Kinect Motion-Recognition (키넥트 모션인식과 ECG센서의 심박수 측정을 기반한 스마트 원격 재활운동 시스템)

  • Kim, Jong-Jin;Gwon, Seong-Ju;Lee, Young-Sook;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2015
  • The Microsoft Kinect is a motion sensing input device which is widely used for many motion recognition applications such as fitness, sports, and rehabilitation. Until now, most of remote rehabilitation systems with the Microsoft Kinect have allowed the user or patient to do rehabilitation or fitness by following the motion of a video screen. However in this paper we propose a smart remote rehabilitation system with the Microsoft Kinect motion sensor and a wearable ECG sensor which can allow patients to offer monitoring of the individual's performance and personalized feedback on rehabilitation exercises. The proposed noble smart remote rehabilitation is able to monitor and measure the state of the patient's condition during rehabilitation exercise, and transmits it to the prescriber. This system can give feedback to a prescriber, a doctor and a patient for improving and recovering motor performance. Thus, the efficient rehabilitation training service can be provided to patient in response to changes of patient's condition during exercise.

Stereoscopic Video Coding for Subway Accident Monitoring System (지하철 사고 감시를 위한 스테레오 비디오 부호화 기법)

  • Kim Gil-Dong;Park Sung-Hyuk;Lee Hanmin;Oh Seh-Chan
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.559-565
    • /
    • 2005
  • In this paper, we propose a stereoscopic video coding scheme for subway accident monitoring system. The proposed designed for providing flexible video among various displays, such ass control center, station employees and train driver. We uses MPEG-2 standard for coding the left-view sequence and IBMDC coding scheme predicts matching block by interpolating both motion and disparity predicted macroblocks. To provide efficient stereoscopic video service, we define both temporally and spatially scalable layers for each eye's-view by using the concept of Spatio-Temporal scalability. The experimental results show the efficiency of proposed coding scheme by comparison with already known methods and the advantages of disparity estimation in terms of scalability overhead. According to the experimental results, we expect the proposed functionalities will play a key role in establishing highly flexible stereoscopic video codec for ubiquitous display environment where devices and network connections are heterogeneous.

Implementation of Real-Time Multi-Camera Video Surveillance System with Automatic Resolution Control Using Motion Detection (움직임 감지를 사용하여 영상 해상도를 자동 제어하는 실시간 다중 카메라 영상 감시 시스템의 구현)

  • Jung, Seulkee;Lee, Jong-Bae;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.612-619
    • /
    • 2014
  • This paper proposes a real-time multi-camera video surveillance system with automatic resolution control using motion detection. In ordinary times, it acquires 4 channels of QVGA images, and it merges them into single VGA image and transmit it. When motion is detected, it automatically increases the resolution of motion-occurring channel to VGA and decreases those of 3 other channels to QQVGA, and then these images are overlaid and transmitted. Thus, it can magnifies and watches the motion-occurring channel while maintaining transmission bandwidth and monitoring all other channels. When it is synthesized with 0.18 um technology, the maximum operating frequency is 110 MHz, which can theoretically support 4 HD cameras.

A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network (무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구)

  • Go, Seong-Il;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • Since a Holter monitor records a patients' ECG when he is in motion, it can monitor complex heart disease effectively. But it can not handle a sudden heart disease because the diagnosis process will be done only after 24 hours. So in this study, a model of ambulatory monitoring system using wireless data communication network is proposed. And a mobile ECG equipment and a doctors' terminal are developed for the proposed system implementation. As a result, we can evaluate that the proposed ambulatory monitoring system is suitable for the management of ambulatory patients who may be at risk form sudden cardiac abnormalities.

  • PDF

Characteristics of Feed Mechanism in NC Lathe (수치제어선반의 이송특성에 관한 연구)

  • 여인완;박철우;이상조
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.104-118
    • /
    • 1998
  • In this paper, the motion of ballscrew and shape of workpiece are the main objective variables varying with load conditions. To verify feed mechanism in NC lathe, the monitoring system is designed and cutting condition variables are spindle speed depth of cut and feed. During machining, rotation number of ballscrew motion of ballscrew in direction to gravity center and cutting force are measured. After machining, the roughness of workpiece is measured.

  • PDF

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

A Vector Instruction-based RISC Architecture for a Photovoltaic System Monitoring Camera

  • Choi, Youngho;Ahn, Hyungkeun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.278-282
    • /
    • 2012
  • Photovoltaic systems have emerged to be one of the cleanest energy systems. Therefore, many large scale solar parks and PV farms have been built to prepare for the post fossil fuel ages. However, due to their large scale, to efficiently manage and operate PV systems, they need to be visually monitored within the range of infrared ray through the Internet. To satisfy this need, the efficient implementation of a high performance video compression standard is required. This paper therefore presents an implementation of H.264 motion estimation, which is one of the most data-intensive and complicated functions in H.264. To achieve this, this work implements vector instructions in hardware and incorporates them in a generic RISC processor architecture, thus increasing the processing speed while minimizing hardware and software design efforts. Extensive simulation results show that this proposed implementation can process motion estimations up to 13 times faster.

Alarm System for Sudden Infant Death using Bio-Signals (생체 신호를 활용한 영아 돌연사 알람 시스템)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.197-202
    • /
    • 2016
  • In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.