• Title/Summary/Keyword: Motion Artifact

Search Result 150, Processing Time 0.025 seconds

The Motion Artifact Reduction using Periodic Moving Average Filter (주기적 이동평균필터를 이용한 동잡음 제거)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.75-82
    • /
    • 2012
  • The Photoplethysmogram is a similar periodic signal that synchronized to a heartbeat. In this paper, we propose a periodic moving average filter that use similarity of Photoplethysmogram. This filtering method has the average value of each samples through separating the cycle of PPG signal. If there are some motion artifacts in continuous PPG signal, disjoin the signal based on cycle. And then, we made these signals to have same cycle by coordinating the number of sample. After arrange these cycles in 2 dimension, we put the average value of each samples from starting till now. So, we can eliminate the motion artifacts without damaged PPG signal.

Heart Rate Monitoring Using Motion Artifact Modeling with MISO Filters (MISO 필터 기반의 동잡음 모델링을 이용한 심박수 모니터링)

  • Kim, Sunho;Lee, Jungsub;Kang, Hyunil;Ohn, Baeksan;Baek, Gyehyun;Jung, Minkyu;Im, Sungbin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.18-26
    • /
    • 2015
  • Measuring the heart rate during exercise is important to properly control the amount of exercise. With the recent advent of smart device usage, there is a dramatic increase in interest in devices for the real-time measurement of the heart rate during exercise. During intensive exercise, accurate heart rate estimation from wrist-type photoplethysmography (PPG) signals is a very difficult problem due to motion artifact (MA). In this study, we propose an efficient algorithm for an accurate estimation of the heart rate from wrist-type PPG signals. For the twelve data sets, the proposed algorithm achieves the average absolute error of 1.38 beat per minute (BPM) and the Pearson correlation between the estimates and the ground-truth of heart rate was 0.9922. The proposed algorithm presents the strengths in an accurate estimation together with a fast computation speed, which is attractive in application to wearable devices.

A Study on the Implementation of Transmission type PPG Measurement Device in a Wrist Watch (손목시계 형태의 투과형 PPG 측정 장치의 구현에 관한 연구)

  • Kim, Namsub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.161-167
    • /
    • 2017
  • This paper presents an effective PPG measurement device in a wrist watch for smart healthcare. PPG can be acquired by measuring absorption of light and PPG measurement device is classified as transmission and reflection type. Reflection type is easy to implement but vulnerable to motion artifact. Moreover, reflection type must use 2 hands at once if the device is implemeted in a wrist watch. This paper describes the implementation of robust transmission type PPG measurement device by using previous developed reflection type device. PPG sensor is clip type and can be separated from the device so that the influence of motion artifact can be reduced. The proposed device can transmit the measured signal in real-time and is useful for smart healthcare. For evaluation of the proposed device, PPG signals are compared with reflection type in the same condition. The results show that the proposed device has 20% improvement in performance.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

Contour Shape Matching based Motion Vector Estimation for Subfield Gray-scale Display Devices (서브필드계조방식 디스플레이 장치를 위한 컨투어 쉐이프 매칭 기반의 모션벡터 추정)

  • Choi, Im-Su;Kim, Jae-Hee
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.327-328
    • /
    • 2007
  • A contour shape matching based pixel motion estimation is proposed. The pixel motion information is very useful to compensate the motion artifact generated at the specific gray level contours in the moving image for subfield gray-scale display devices. In this motion estimation method, the gray level boundary contours are extracted from the input image. Then using contour shape matching, the most similar contour in next frame is found, and the contour is divided into segment unit. The pixel motion vector is estimated from the displacement of the each segment in the contour by segment matching. From this method, more precise motion vector can be estimated and this method is more robust to image motion with rotation or from illumination variations.

  • PDF

Robust Least Squares Motion Deblurring Using Inertial Sensor for Strapdown Image IR Sensors (스트랩다운 적외선 영상센서를 위한 관성센서 기반 강인최소자승 움직임 훼손영상 복원 기법)

  • Kim, Ki-Seung;Ra, Sung-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.4
    • /
    • pp.314-320
    • /
    • 2012
  • This paper proposes a new robust motion deblurring filter using the inertial sensor measurements for strapdown image IR applications. With taking the PSF measurement error into account, the motion blurred image is modeled by the linear uncertain state space equation with the noise corrupted measurement matrix and the stochastic parameter uncertainty. This motivates us to solve the motion deblurring problem based on the recently developed robust least squares estimation theory. In order to suppress the ringing effect on the deblurred image, the robust least squares estimator is slightly modified by adoping the ridge-regression concept. Through the computer simulations using the actual IR scenes, it is demonstrated that the proposed algorithm shows superior and reliable motion deblurring performance even in the presence of time-varying motion artifact.

Characterization of Motion Interpolation in 120Hz Systems

  • Shin, Byung-Hyuk;Kim, Kyung-Woo;Park, Min-Kyu;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.681-684
    • /
    • 2008
  • Motion interpolation is adopted and has been spread widely into market since it is effective in reducing motion blur, which is considered as weak characteristic due to slow response time of liquid crystal and hold-type display. 120Hz driving using interpolated frames achieves better moving picture quality with less motion blur and less motion judder. However, errors in the interpolated frames can cause visual artifacts such as static text breakup, halos, and occlusions. This paper focuses on categorizing characteristics of visual artifacts and on reducing side-effects by using information from original frames in special cases.

  • PDF

Fast Motion Synthesis of Massive Number of Quadruped Animals

  • Sung, Man-Kyu
    • International Journal of Contents
    • /
    • v.7 no.3
    • /
    • pp.19-28
    • /
    • 2011
  • This paper presents a fast and practical motion synthesis algorithm for massive number of quadruped animals. The algorithm constructs so called speed maps that contain a set of same style motions but different speed from a single cyclic motion by using IK(Inverse Kinematics) solver. Then, those speed maps are connected each other to form a motion graph. At run time, given a point trajectory that obtained from user specification or simulators, the algorithm retrieves proper speed motions from the graph, and modifies and stitches them together to create a long seamless motion in real time. Since our algorithm mainly targets on the massive quadruped animal motions, the motion graph create wide variety of different size of characters for each trajectory and automatically adjusted synthesized motions without causing artifact such as foot skating. The performance of algorithm is verified through several experiments

Cancellation of Motion Artifact in MRI Image Plane (MRI 촬상단면내의 체동 아티팩트의 제거)

  • 김응규;권영도
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1075-1078
    • /
    • 1999
  • In this study, a new algorithm for canceling MRI artifacts through the translational motion of image plane is presented. Bloating is often makes problems in a clinical diagnosis. Assuming that the head moves up and down due to breathing, rigid translational motions in only y(phase encoding axis) direction is treated. First, we notice that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal, and the non zero area of the spectrum just corresponds to x axis projected area of the density function. So the motion is estimated by tracing the edges of the spectrum, and the x directional motion is canceled by shifting the spectrum in inverse direction. Next, the y directional motion is canceled using a new constraint, with which the motion component and the true image component can be separated. Finally, the effectiveness of this algorithm is shown by using a phantom with simulated motions.

  • PDF