• Title/Summary/Keyword: Motion Analyzer

Search Result 84, Processing Time 0.025 seconds

A Study on the Effectiveness of Wel-Tech-based Motion Analyzer

  • Young-Hee RO;Hye-Min KIL;Hyun-Soo LEE;Hyun-Jin LEE;Yeon-Ah KIM;Chung-Man GUK
    • The Journal of Economics, Marketing and Management
    • /
    • v.12 no.6
    • /
    • pp.79-89
    • /
    • 2024
  • Purpose: TIn an aging society, maintaining the physical and mental health of middle-aged and older adults and enhancing their quality of life have become significant social challenges. This study aimed to explore the effectiveness, limitations, and areas for improvement of AI-based motion analyzers by providing a personalized exercise program to 21 individuals aged 50 and above who utilized the OO Comprehensive Social Welfare Center. Research design, data and methodology: Over six months, participants engaged in personalized exercise programs designed by the motion analyzer, and their results were analyzed. Results: The analysis revealed that AI-based motion analyzers hold promising potential as effective tools for improving the health of middle-aged and older adults. Conclusions: By collecting and quantitatively analyzing participants' exercise performance data in real time, motion analyzers were confirmed to possess practical potential for active application in health management and rehabilitation therapy processes.

Nonlinear Vibration Phenomenon for the Slender Rectangular Cantilever Beam (얇은 직사각형 외팔보의 비선형 진동현상)

  • Park, Chul-Hui;Cho, Chong-Du;Piao, Chang-Hao
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1314-1321
    • /
    • 2004
  • The non-linear responses of a slender rectangular cantilever beam subjected to lateral harmonic base-excitation are investigated by the 2-channel FFT analyzer. Both linear and nonlinear behaviors of the cantilever beam are compared with each other. Bending mode, torsional mode, and transverse mode are coupled in such a way that the energy transfer between them are observed. Especially, superharmonic, subharmonic, and chaotic motions which result from the unstable inertia terms in the transverse mode are analyzed by the FFT analyzer The aim is to give the explanations of the route to chaos, i.e., harmonic motion \longrightarrow superharmonic motion \longrightarrow subharmonic motion \longrightarrow chaos.

Development of Spine Motion Analyzer (척추운동 분석기의 개발)

  • Kim, Y.E.;Roh, B.H.;Ryu, J.H.;Ahn, J.H.;Lee, C.K.;Choi, K.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.266-270
    • /
    • 1996
  • External linkage type spine motion analyzer was developed for measuring relative trunk motion respect to the pelvis. A special program for calculation of the relative angular motion and graphical display were also developed. The developed device assured its accuracy and conveniency after application to 15 normal volunteers and 18 patients after fixation and decompression surgery. Compare to the normal subjects, patients shows different angular motion especially in the angular acceleration.

  • PDF

Development of a Human Motion Analyzer (인체 동작 분석기의 개발)

  • 김민기;김성호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System (MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구)

  • Choi Hae Man;Monji Hideaki;Matsui Goichi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

Particle path and performance evaluation of differential mobility analyzer (Differential Mobility Analyzer(DMA)내의 입자운동 및 특성 분석)

  • An, Gang-Ho;Kim, Nam-Hyo;Lee, Jong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.2005-2013
    • /
    • 1996
  • Particle paths and flow fields in a prototype differential mobility analyzer (DMA) were numerically analyzed solving Navier-Stokes equation, electric field equation and particle motion considering viscous drag force, Coulomb force and polarization force. Analytically predicted particle diameters for the prototype DMA are in good agreement with the measured particle diameters within $\pm$1%. And the analytically predicted particle diameters are also in good agreement with numerical results for the prototype DMA.

Development of spine motion analyzer (척추운동 분석기의 개발)

  • 김영은;노병현;유진환;안정호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.137-146
    • /
    • 1997
  • External linkage type spine motion analysis was developed for relative trunk motion respect to the pelvis. A special programs for calculation of the relative angular motion and for graphical display were also developed. The developed device assured its accuracy and conveniency after application to 15 normal vol- unteers. Compare to the normal subjects, 18 patients treated with fixations and decompression surgery showed relatively large coupling motion. Optimal trajectory of the trunk motion derived from mathematical model in flexion and extension matched well with measurement for normal subjects.

  • PDF

Understanding of 3D Human Body Motion based on Mono-Vision (단일 비전 기반 인체의 3차원 운동 해석)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.18B no.4
    • /
    • pp.193-200
    • /
    • 2011
  • This paper proposes a low-cost visual analyzer algorithm of human body motion for real-time applications such as human-computer interfacing, virtual reality applications in medicine and telemonitoring of patients. To reduce cost of its use, we design the algorithm to use a single camera. To make the proposed system to be used more conveniently, we avoid from using optical markers. To make the proposed algorithm be convenient for real-time applications, we design it to have a closed-form with high accuracy. To design a closed-form algorithm, we propose an idea that formulates motion of a human body joint as a 2D universal joint model instead of a common 3D spherical joint model, without any kins of approximation. To make the closed-form algorithm has high accuracy, we formulates the estimation process to be an optimization problem. Thus-desined algorithm is applied to each joint of the human body one after another. Through experiments we show that human body motion capturing can be performed in an efficient and robust manner by using our algorithm.

Reconstruction of Anterior Cruciate Ligament with Human Allograft (동종 이식건을 이용한 전방 십자 인대 재건술)

  • Suh Jeung-Tak;Cheon Sang-Jin;Lee Jung-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • Purpose : The purpose of this study is to evaluate the clinical outcomes and radiological changes after reconstruction of anterior cruciate ligament with human allograft. Material and Method : Authors analyzed 22 cases of anterior cruciate ligament allograft reconstruction which were done from January, 1995 to December, 1998 and could be followed up for a year or more. All cases were followed and reviewed in terms of anterior drawer test, Lachman test, Pivot shift test, radiographic examination, knee range of motion, and side-to-side difference of anteroior tibial translation using CA-4000 knee motion analyzer, and Lysholm knee scoring system. Result : The mean Lysholm knee score was 54 preoperatively and improved to 81 postoperatively by average of 27. The side-to-side difference of anterior tibial translation using CA-4000 knee motion analyser was less than 3 mm in 16 cases$(73\%)$, between 3 and 5 mm in 4 cases$(18\%)$, and greater than 6 min in 2 cases$(9\%)$. Average tibial tunnel enlargement was 1.5 mm, but there were not any osteoiysis or cystic formation along the tunnel and no relationship between tunnel enlargement and clinical outcome. Conclusion : Although this study had limited cases, clinical results of anterior cruciate allograft reconstruction were similar to those of reconstruction with autograft reported in the literatures. We think that allograft is an acceptable substitute fer autograft in anterior cruciate ligament reconstruction.

  • PDF

A Study on the Lower Body Range of Motion(Using a 3-D Motion Analysis System) about Korean Adults (한국성인 남자의 하체 동작범위 연구 - 3D 동작분석 장치를 이용하여 -)

  • 류신아;박길순
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.741-753
    • /
    • 2000
  • The purpose of this study : 1. The total 24 range measurements of active dynamic motion of 40 subjects(20's and 30's, and 40's∼60's) using previous studies. The results were compared with the other studies in the aspects of age. In this study, The 3-D motion analysis system consists of VICON 140, data acquisition system, and data analysis program called by KRISSMAS. VICON 140 is dynamic motion analyzer, and KRISSMAS is a program developed for analysis of the data captured from the VICON. The results of this study were as follows : 1. Comparing 20's∼30's and 40's∼60's the result shows that 40's∼60's have smaller ROM at the most joints(Thoratic and Lumber, Hip Joint, Knee Joint, Ankle Joint), which is inconsistent with the previous result. The reason is that most investigations were carried out using traditional measurement equipments, which have encountered difficulty in quantifying the exact motion of the body. 2. There are no significant mean difference between the right and the left side. Most of the significances were not high(〉0.05).

  • PDF