• Title/Summary/Keyword: Morphological Defect

Search Result 53, Processing Time 0.021 seconds

A directional defect detection in texture image using mathematical morphology (수리 형태론을 이용한 texture 영상의 방향성 결함검출)

  • 김한균;윤정민;오주환;최태영
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.141-147
    • /
    • 1996
  • In this paper an improved morphological algorithm for directional defect detection is proposed, where the defect is parallel to the texture image. The algorithm is based on obtaining the background image while removing the defect by comparing every directional morphological result with max or min except that of defect. The defect can of defect and the background image. For a computer simulation, it is shown that the proposed method has better performance than the conventional algorithm.

  • PDF

Sequential Defect Region Segmentation according to Defect Possibility in TFT-LCD Image (TFT-LCD영상에서 결함 가능성에 따른 순차적 결함영역 분할)

  • Chang, Chung Hwan;Lee, SeungMin;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.5
    • /
    • pp.633-640
    • /
    • 2020
  • Defect region segmentation of TFT-LCD images is performed by combining defect pixels detected by a defect detection method into defect region, or by using morphological operations to segment defect region. Therefore, the result of segmentation of the defect region is highly dependent on the defect detection result. In this paper, we propose a method which segments defect regions sequentially according to the possibility of being included in defect regions in TFT-LCD images. The proposed method repeats the process of detecting a seed using the median value and the median absolute deviation of the image, and segments the defect region using the seeded region growing method. We confirmed the superiority of the proposed method to segment defect regions using pseudo-images and real TFT-LCD images.

TFT-LCD Defect Blob Detection based on Sequential Defect Detection Method (순차적 결함 검출 방법에 기반한 TFT-LCD 결함 영역 검출)

  • Lee, Eunyoung;Park, Kil-Houm
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.2
    • /
    • pp.73-83
    • /
    • 2015
  • This paper proposes a TFT-LCD defect blob detection algorithm using the sequential defect detection method. First, for every pixel, a defect possibility is determined by the intensity difference and the defect candidates are detected according to the sequential defect detection method. For detected candidate pixels, the defect probability that indicates a potential included in the defect according to the each step. By applying the morphological operation, blobs are comprised of the detected candidates and the defect blobs are detected using the defect possibility of blobs. The validity of the proposed method was demonstrated a simulated image and also then it was tested a real TFT-LCD image. By the experimental results, the proposed method is very effective in TFT-LCD detect detection.

THE RECONSTRUCTION OF THE MAXILLARY WALL DEFECT USING MICRO-TITANIUM MESH (Micro-titanium mesh를 이용한 상악골 결손부의 재건술에 관한 연구)

  • Kim, Seong-Gon;Choi, You-Sung;Choung, Pill-Hoon;Lee, Hee-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.197-203
    • /
    • 2000
  • Maxillary defect may be induced by trauma, inflammation, cyst, tumor and surgical procedure. In case of limited wall defect, free bone graft has been preferred. But it has some problems such as postoperative bone resorption and soft tissue inclusion to recipient site. And we can not use free bone in the case who has inflammation in the donor site. So we used the micro-titanium mesh as reconstructive material for the maxillary wall defect. We had operated 8 patients who were diagnosed as maxillary partial defects from June 1997 to September 1998 in the Chin-Hae military hospital. They were 1 case of antral wall defect, 1 case of palatal wall defect, 5 cases of infra-orbital wall defects and 1 case of oroantral fistula case. As a result, the micro-titanium mesh has shown the morphological stability and biocompatibility and it could be used in case who has infection. And mesh structure could prevent soft tissue ingrowth to bony defect area. Thus it can be used to the case of maxillary partial defect successfully.

  • PDF

Surgical Correction of Double-outlet Right Ventricle with Atrioventricular Discordance - A case report - (심방심실착위를 동반한 양대혈관 우심실기시증의 수술치험 1례)

  • 최대융
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1471-1475
    • /
    • 1992
  • Within the group of congenital cardiac anomalies manifesting atrioventricular discordance, there exists a subset of hearts characterized by the additional presence of double outlet of the morphological right ventricle. Most of these hearts have associated pulmonary stenosis and abnormal direction of the cardiac apex, and all have a ventricular septal defect. Recently, a 10-year old boy underwent successful surgical correction of double outlet right ventricle with atrioventricular discordance. Diagnostic confirmation was made by 2-D echocardiography, cardiac catheterization and cineangiocardiography. The operation consisted of patch closure of ventricular septal defect so as to leave both great arteries draining the systemic[morphologically right] ventricle, and insertion of an extracardiac valved conduit between the morphological left ventricle and the distal end of the proximally oversewn pulmonary artery. Postoperative course was uneventful.

  • PDF

Study on Machine Vision Algorithms for LCD Defects Detection (LCD 결함 검출을 위한 머신 비전 알고리즘 연구)

  • Jung, Min-Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.59-63
    • /
    • 2010
  • This paper proposes computer visual inspection algorithms for various LCD defects which are found in a manufacturing process. Modular vision processing steps are required in order to detect different types of LCD defects. Those key modules include RGB filtering for pixel defects, gray-scale morphological processing and Hough transform for line defects, and adaptive threshold for spot defects. The proposed algorithms can give users detailed information on the type of defects in the LCD panel, the size of defect, and its location. The machine vision inspection system is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiment results show that the proposed algorithms are quite successful.

A neural network approach to defect classification on printed circuit boards (인쇄 회로 기판의 결함 검출 및 인식 알고리즘)

  • An, Sang-Seop;No, Byeong-Ok;Yu, Yeong-Gi;Jo, Hyeong-Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.337-343
    • /
    • 1996
  • In this paper, we investigate the defect detection by making use of pre-made reference image data and classify the defects by using the artificial neural network. The approach is composed of three main parts. The first step consists of a proper generation of two reference image data by using a low level morphological technique. The second step proceeds by performing three times logical bit operations between two ready-made reference images and just captured image to be tested. This results in defects image only. In the third step, by extracting four features from each detected defect, followed by assigning them into the input nodes of an already trained artificial neural network we can obtain a defect class corresponding to the features. All of the image data are formed in a bit level for the reduction of data size as well as time saving. Experimental results show that proposed algorithms are found to be effective for flexible defect detection, robust classification, and high speed process by adopting a simple logic operation.

  • PDF

Transaortic Closure of Ventricular Septal Defect in Congenitally Corrected Transposition of Great Arteries with Pulmonary Stenosis (대동맥절개를 퇘한 교정형 대혈관전위증의 심실중격결손 봉합)

  • An, Hong-Nam;Lee, Jong-Tae;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.748-756
    • /
    • 1988
  • Transaortic closure of ventricular septal defect, suturing a patch on the morphological right ventricular side in patients with congenitally corrected transposition of great arteries might help to avoid postoperative complete heart block if the aorta is large and the subaortic conus is not well developed. In two patients[aged 6 and 16 years] with congenitally corrected transposition of great arteries, ventricular septal defect, and pulmonary stenosis, transaortic closure of ventricular septal defect was performed. No postoperative complete heart block resulted. One hospital death occurred because of sepsis who had underwent reoperation due to bleeding from the aortotomy site. Minimal aortic regurgitation developed in another patient.

  • PDF

Automatic Detection Method for Mura Defects on Display Films Using Morphological Image Processing and Labeling

  • Cho, Sung-Je;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.234-239
    • /
    • 2014
  • This paper proposes a new automatic detection method to inspect mura defects on display film surface using morphological image processing and labeling. This automatic detection method for mura defects on display films comprises 3 phases of preprocessing with morphological image processing, Gabor filtering, and labeling. Since distorted results could be obtained with the presence of non-uniform illumination, preprocessing step reduces illumination components using morphological image processing. In Gabor filtering, mura images are created with binary coded mura components using Gabor filters. Subsequently, labeling is a final phase of finding the mura defect area using the difference between large mura defects and values in the periphery. To evaluate the accuracy of the proposed detection method, detection rate was assessed by applying the method in 200 display film samples. As a result, the detection rate was high at about 95.5%. Moreover, the study was able to acquire reliable results using the Semu index for luminance mura in image quality inspection.

Morphological defects of sperm and their association with motility, fertility, and hatchability in four Korean native chicken breeds

  • Feyisa, Shiferaw Garoma;Park, Young Hyun;Kim, Young Min;Lee, Bo Ram;Jung, Kyung Min;Choi, Seong Bok;Cho, Chang Yeon;Han, Jae Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1160-1168
    • /
    • 2018
  • Objective: This study was conducted to compare morphological defects, viability, motility (MOT), fertility (F), and hatchability (H) in four Korean native chicken breeds (KNCBs), and to evaluate whether defective segments of spermatozoa are associated with MOT, F, and H. Methods: Four KNCBs, including Korean Ogye (KO), Hwangbong (HB), Hyunin Black (HH), and Hoengseong Yakdak (HY) were used. White Leghorn (WL) was used as a control. Nine cocks from each breed were randomly assigned into three groups. Semen was collected by abdominal massage method. Eosin-nigrosin staining method was used to identify live-dead spermatozoa. Different segments and specific morphological defects of spermatozoa were identified using 4', 6-diamidino-2-phenylidole and MitoTracker Red CMXRos. F and H rates were evaluated following artificial insemination (AI). Results: KO had the highest MOT rate compared to HY. Viable normal sperm rates of KO and HH were high and comparable with WL. HY spermatozoa had the highest viable abnormal sperm (VAS) or morphological defect rate followed by HB. Likewise, HB spermatozoa had the highest dead sperm (dead) rate compared to KO, HY, and WL. Bent, coiled, detached, broken, and knotted were common identified specific morphological defects for all breeds. Most morphological defects were at the head and tail in all breeds. VAS showed strong negative correlation with MOT (r = -0.697) and F (r = -0.609). Similarly, defective tail was negatively correlated with MOT (r = -0.587), F (r = -0.797), and H (r = -0.448). The F and H rates of KO and WL were comparable. Conclusion: These data indicate that most identified specific morphological defects are at the head and tail. VAS and defective tail were associated with poor motility, F, and H. KNCBs showed more morphological defects than WL. Finally, these results will facilitate successful AI and semen cryopreservation.