• Title/Summary/Keyword: Monte Carlo Radiation Transport

Search Result 77, Processing Time 0.037 seconds

Optimization of shielding to reduce cosmic radiation damage to packaged semiconductors during air transport using Monte Carlo simulation

  • Lee, Ju Hyuk;Kim, Hyun Nam;Jeong, Heon Yong;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1817-1825
    • /
    • 2020
  • Background: Cosmic ray-induced particles can lead to failure of semiconductors packaged for export during air transport. This work performed MCNP 6.2 simulations to optimize shielding against neutrons and protons induced by cosmic radiation Methods and materials: The energy spectra of protons and neutrons by incident angle at the flight altitude were determined using atmospheric cuboid model. Various candidates for the shielding materials and the geometry of the Unit Load Device Container were evaluated to determine the conditions that allow optimal shielding at all sides of the container. Results: It was found that neutrons and protons, at the flight altitude, generally travel with a downward trajectory especially for the particles with high energy. This indicated that the largest number of particles struck the top of the container. Furthermore, the simulation results showed that, among the materials tested, borated polyethylene and stainless steel were the most optimal shielding materials. The optimal shielding structure was also determined with the weight limit of the container in consideration. Conclusions: Under the determined optimal shielding conditions, a significantly reduced number of neutrons and protons reach the contents inside the container, which ultimately reduces the possibility of semiconductor failure during air transport.

Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor (방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가)

  • Lee, Jin Hyung;Kim, Jong Bum
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

Monte Carlo approach for calculation of mass energy absorption coefficients of some amino acids

  • Bozkurt, Ahmet;Sengul, Aycan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3044-3050
    • /
    • 2021
  • This study offers a Monte Carlo alternative for computing mass energy absorption coefficients of any material through calculation of photon energy deposited per mass of the sample and the energy flux obtained inside a sample volume. This approach is applied in this study to evaluate mass energy absorption coefficients of some amino acids found in human body at twenty-eight different photon energies between 10 keV and 20 MeV. The simulations involved a pencil beam source modeled to emit a parallel beam of mono-energetic photons toward a 1 mean free path thick sample of rectangular parallelepiped geometry. All the components in the problem geometry were surrounded by a 100 cm vacuum sphere to avoid any interactions in materials other than the absorber itself. The results computed using the Monte Carlo radiation transport packages MCNP6.2 and GAMOS5.1 were checked against the theoretical values available from the tables of XMUDAT database. These comparisons indicate very good agreement and support the conclusion that Monte Carlo technique utilized in this fashion may be used as a computational tool for determining the mass energy absorption coefficients of any material whose data are not available in the literature.

Preliminary Study of Cosmic-ray Shielding Material Design Using Monte-Carlo Radiation Transport Code (몬테카를로 방사선 수송 모델을 활용한 우주방사선 차폐체 설계 관련 선행연구)

  • Kang, Chang-Woo;Kim, Yeong-Chan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.527-536
    • /
    • 2022
  • The radiation shielding characteristic of neutron shielding material has been studied as the preliminary study in order to design cosmic-ray shielding material. Specially, Soft Magnetic Material, known to be effective in EMP and radiation shielding, has been investigated to check if the material would be applicable to cosmic-ray shielding. In this work, thermal neutron shielding experiment was conducted and the Monte Carlo N-Particle(MCNP) was applied to employ skymap.dat, which is cosmic-ray data embedded in MCNP. As a result, polyethylene, borated polyethylene, and carbon nano tube, containing carbon or hydrogen, have been found to be effective in reduction of neutron flux below 20 MeV (including thermal, epithermal, evaporation). In contrast, the materials composed of iron such as SS316 and Soft Magnetic Material show a good shielding performance in the cascade energy range (above 20 MeV). Since Soft Magnetic Material is consisting of 13% of boron, it can also decrease thermal neutron flux, so it is expected that it would show a significant reduction on the entire range of neutron energy if the Soft Magnetic Material is used with hydrogen and carbon, so called low Z material.

Design and performance prediction of large-area hybrid gamma imaging system (LAHGIS) for localization of low-level radioactive material

  • Lee, Hyun Su;Kim, Jae Hyeon;Lee, Junyoung;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1259-1265
    • /
    • 2021
  • In the present study, a large-area hybrid gamma imaging system was designed by adopting coded aperture imaging on the basis of a large-area Compton camera to achieve high imaging performance throughout a broad energy range (100-2000 keV). The system consisting of a tungsten coded aperture mask and monolithic NaI(Tl) scintillation detectors was designed through a series of Geant4 Monte Carlo radiation transport simulations, in consideration of both imaging sensitivity and imaging resolution. Then, the performance of the system was predicted by Geant4 Monte Carlo simulations for point sources under various conditions. Our simulation results show that the system provides very high imaging sensitivity (i.e., low values for minimum detectable activity, MDA), thus allowing for imaging of low-activity sources at distances impossible with coded aperture imaging or Compton imaging alone. In addition, the imaging resolution of the system was found to be high (i.e., around 6°) over the broad energy range of 59.5-1330 keV.

Monte Carlo Calculation for Production Cross-Sections of Projectile's Isotopes from Therapeutic Carbon and Helium Ion Beams in Different Materials

  • Quazi Muhammad Rashed Nizam;Asif Ahmed;Iftekhar Ahmed
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.204-212
    • /
    • 2023
  • Background: Isotopes of the projectile may be produced along the beam path during the irradiation of a target by a heavy ion due to inelastic interactions with the media. This study analyzed the production cross-section of carbon (C) and Helium (He) projectile's isotopes resulting from the interactions of these beams with different materials along the beam path. Materials and Methods: In this study, we transport C and He ion beams through different materials. This transportation was made by the Monte Carlo simulation. Particle and Heavy Ion Transport code System (PHITS) has been used for this calculation. Results and Discussion: It has been found that 10C, 11C, and 13C from the 12C ion beam and 3He from the 4He ion beam are significant projectile's isotopes that have higher flux than other isotopes of these projectiles. The 4He ion beam has a higher projectile's isotope production cross-section along the beam path, which adds more impurities to the beam than the 12C ion beam. These projectile's isotopes from both the 12C and 4He ion beams have higher production cross-sections in hydrogenous materials like water or polyethylene. Conclusion: It is important to distinguish these projectile's isotopes from the primary beam particles to obtain a precise and accurate cross-section result by minimizing the error during measurement with a nuclear track detector. This study will show the trend of the production probability of projectile's isotopes for these ion beams.

Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling

  • Arectout, A.;Zidouh, I.;Sadeq, Y.;Azougagh, M.;Maroufi, B.;Chakir, E.;Boukhal, H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.301-309
    • /
    • 2022
  • This work aims to establish some X-ray qualities recommended by the International Standard Organization (ISO) using the half-value layer (HVL) and Hp(10) dosimetry approaches. The HVL values of the following qualities N-60, N-80, N-100, N-150 and N-250 were determined using various attenuation layers. The obtained results were compared to those of reference X-ray beam qualities and a good agreement was found (difference less than 5% for all qualities). The GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations) radiation transport Monte Carlo toolkit was employed to simulate the production of X-ray spectra. The characteristics HVLs, mean energy and the spectral resolution of simulated spectra have been calculated and turned out to be conform to the ISO reference ones (difference less than the limit allowed by ISO). Furthermore, the conversion coefficients from air kerma to personal dose equivalent for simulated and measured spectra were fairly similar (the maximum difference less than 4.2%).

Understanding Phytosanitary Irradiation Treatment of Pineapple Using Monte Carlo Simulation

  • Kim, Jongsoon;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Goo;Park, Jong-Min;Choi, Won-Sik
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.87-94
    • /
    • 2013
  • Purpose: Pineapple is now the third most important tropical fruit in world production after banana and citrus. Phytosanitary irradiation is recognized as a promising alternative treatment to chemical fumigation. However, most of the phytosanitary irradiation studies have dealt with physiochemical properties and its efficacy. Accurate dose calculation is crucial for ensuring proper process control in phytosanitary irradiation. The objective of this study was to optimize phytosanitary irradiation treatment of pineapple in various radiation sources using Monte Carlo simulation. Methods: 3-D geometry and component densities of the pineapple, extracted from CT scan data, were entered into a radiation transport Monte Carlo code (MCNP5) to obtain simulated dose distribution. Radiation energy used for simulation were 2 MeV (low-energy) and 10 MeV (high-energy) for electron beams, 1.25 MeV for gamma-rays, and 5 MeV for X-rays. Results: For low-energy electron beam simulation, electrons penetrated up to 0.75 cm from the pineapple skin, which is good for controlling insect eggs laid just below the fruit surface. For high-energy electron beam simulation, electrons penetrated up to 4.5 cm and the irradiation area occupied 60.2% of the whole area at single-side irradiation and 90.6% at double-side irradiation. For a single-side only gamma- and X-ray source simulation, the entire pineapple was irradiated and dose uniformity ratios (Dmax/Dmin) were 2.23 and 2.19, respectively. Even though both sources had all greater penetrating capability, the X-ray treatment is safer and the gamma-ray treatment is more widely used due to their availability. Conclusions: These results are invaluable for optimizing phytosanitary irradiation treatment planning of pineapple.

Application of Discrete-Ordinate Method to the Time Dependent Radiative Heat Transfer Calculations (방향차분법을 적용한 시간종속 복사 열전달 계산)

  • Noh, Tae-Wan
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.250-255
    • /
    • 2006
  • In this study, the discrete ordinates method which has been widely used in the solution of neutron transport equation is applied to the solution of the time dependent radiative transfer equation. The self-adjoint form of the second order radiation intensity equation is used to enhance the stability of the solution, and a new multi-step linearization method is developed to avoid the nonlinearity in the material temperature equation. This new solution method is applied to the well known Marshak wave problem, and the numerical result is compared with that of the conventional Monte-Carlo method.