• Title/Summary/Keyword: Monitoring scan

Search Result 113, Processing Time 0.023 seconds

Detection of Recurrence in a Surveillance Program for Epithelial Ovarian Cancer

  • Suprasert, Prapaporn;Chalapati, Wadwilai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7193-7196
    • /
    • 2013
  • Ovarian cancer patients need a surveillance program for the detection of tumor progression after completion of treatment. The methods generally consist of history taking, physical examination, tumor marker monitoring and imaging. However, the details of recurrence detection with each method are not well defined. To clarify this issue, ovarian cancer patients who achieved complete or partial responses and developed tumor progression at the follow up time between January 2004 and December 2010 in University Hospital Chiang Mai, Thailand, were reviewed. Clinical data, CA 125 level and imaging results at the tumor progression time were recorded and analyzed. There were 144 ovarian cancer patients meeting the inclusion criteria with the mean age of 51 years and 62.5% of them were in an advanced stage. Complete response was achieved in 89 patients (61.8%) after primary treatment. The median progression free survival and overall survival were 15.5 months and 37.5 months, respectively. Abnormal symptoms presented in 49.3% of the studied patients and 59.7% developed physical examination abnormalities. In addition, CA 125 was elevated in 89.6% while in 74.3% of tumor progression was identified by CT-scan. Short treatment time period and a high level of CA 125 were significant independent prognostic factors in these patients. In conclusion, careful history taking, physical examination and monitoring of CA 125 levels are important methods for tumor progression detection in a surveillance program for epithelial ovarian cancer patients.

Acoustic Emission Monitoring of Lightning-Damaged CFRP Laminates during Compression-after-Impact Test

  • Shin, Jae-Ha;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.269-275
    • /
    • 2012
  • Carbon-fiber reinforced plastic(CFRP) laminates made of nano-particle-coated carbon fibers and damaged by a simulated lightning strike were tested under compression-after-impact(CAI) mode, during which the damage progress due to compressive loading has been monitored by acoustic emission(AE). The impact damage was induced not by mechanical loading but by a simulated lightning strike. Conductive nano-particles were coated directly on the fibers, from which CFRP coupons were made. The coupon were subjected to the strikes with a high voltage/current impulse of 10~40 kA within a few ${\mu}s$. The effects of nano-particle coating and the degree of damage induced by the simulated lightning strikes on AE activities were examined, and the relationship between the compressive residual strength and AE behavior has been evaluated in terms of AE event counts and the onset of AE activity with the compressive loading. The degree of impact damage was also measured in terms of damage area by using ultrasonic C-scan images. The assessment during the CAI tests of damaged CFRP showed that AE monitoring appeared to be useful to differentiate the degree of damage hence the mechanical integrity of composite structures damaged by lightning strikes.

Vibration Evaluation and Accuracy Improvement for a Digital Pile Rebounding and Penetration Monitoring System (DPRMS) (디지털 항타관리기(DPRMS)의 진동영향 평가 및 측정 정밀도 향상 방안에 관한 연구)

  • Hong, Jung-Taek;Lee, Kye-Young;Lee, Sang-Hun;Han, Song-Soo;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.514-520
    • /
    • 2006
  • In this study, the performance of a digital pile rebounding and penetration monitoring system (DPRMS) is evaluated and the measurement precision of the DPRMS is improved. The DPRMS is a high speed line-scanning camera system to measure the rebound and penetration of a pile in a construction work. A main problem in the DPRMS is a measurement error, which is caused by a shock or vibration due to a hammer impact. The measurement error is investigated by analyzing vibration signals of the DPRMS during the impact. Moreover, the frequency response functions of the DPRMS are also analyzed. As a result, it is found that the tripod height has an influence on the DPRMS performance and a shorter tripod is better. One more founding in this study is that the DPRMS should be placed with a appropriate distance from a pile for improving the measurement precision.

Cardiac dose reduction with breathing adapted radiotherapy using self respiration monitoring system for left-sided breast cancer

  • Sung, KiHoon;Lee, Kyu Chan;Lee, Seung Heon;Ahn, So Hyun;Lee, Seok Ho;Choi, Jinho
    • Radiation Oncology Journal
    • /
    • v.32 no.2
    • /
    • pp.84-94
    • /
    • 2014
  • Purpose: To quantify the cardiac dose reduction during breathing adapted radiotherapy using Real-time Position Management (RPM) system in the treatment of left-sided breast cancer. Materials and Methods: Twenty-two patients with left-sided breast cancer underwent CT scans during breathing maneuvers including free breathing (FB), deep inspiration breath-hold (DIBH), and end inspiration breath-hold (EIBH). The RPM system was used to monitor respiratory motion, and the in-house self respiration monitoring (SRM) system was used for visual feedback. For each scan, treatment plans were generated and dosimetric parameters from DIBH and EIBH plans were compared to those of FB plans. Results: All patients completed CT scans with different breathing maneuvers. When compared with FB plans, DIBH plans demonstrated significant reductions in irradiated heart volume and the heart $V_{25}$, with the relative reduction of 71% and 70%, respectively (p < 0.001). EIBH plans also resulted in significantly smaller irradiated heart volume and lower heart $V_{25}$ than FB plans, with the relative reduction of 39% and 37%, respectively (p = 0.002). Despite of significant expansion of lung volume using inspiration breath-hold, there were no significant differences in left lung $V_{25}$ among the three plans. Conclusion: In comparison with FB, both DIBH and EIBH plans demonstrated a significant reduction of radiation dose to the heart. In the training course, SRM system was useful and effective in terms of positional reproducibility and patient compliance.

Study on the Real-time COVID-19 Confirmed Case Web Monitoring System (실시간 코로나19 확진자 웹 모니터링 시스템에 대한 연구)

  • You, Youngkyon;Jo, Seonguk;Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.171-179
    • /
    • 2022
  • This paper introduces a monitoring and tracking system for corona19 confirmed patients based on the collected data by installing a device that can manage the access list at the entrance to each building on the campus. The existing QR-based electronic access list can't measure the temperature of the person entering the building and it is inconvenient that members have to scan their QR codes with a smartphone. In addition, when the state manages information about confirmed patients and contacts on campus, it is not easy for members to quickly share and track information. These could lead to cases where a person is in close contact with an infected person developing another patient. Therefore, this paper introduces a device using face recognition library and a temperature sensor installed at the entrance of each building on the campus, enabling the administrator to monitor the access status and quickly track members of each building in real-time.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

High-Velocity Impact Damage Detection of Gr/Ep Composite Laminates Using Piezoelectric Thin Film Sensor Signals (압전필름센서 신호를 이용한 Gr/Ep 복합재 적층판의 고속충격 손상탐지)

  • Kim, Jin-Won;Kim, In-Gul
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.13-16
    • /
    • 2005
  • The mechanical properties of composite materials may degrade severely in the presence of damage. Especially, the high-velocity impact such as bird strike, a hailstorm, and a small piece of tire or stone during high taxing, can cause sever damage to the structures and sub-system in spite of a very small mass. However, it is not easy to detect the damage in composite plates using a single technique or any conventional methods. In this paper, the PYDF(polyvinylidene fluoride) film sensors and strain gages were used for monitoring impact damage initiation and propagation in composite laminates. The WT(wavelet transform) and STFT(short time Fourier transform) are used to decompose the sensor signals. A ultrasonic C-scan and a digital microscope are also used to examine the extent of the damage in each case. This research demonstrate how various sensing techniques, PVDF sensor in particular, can be used to characterize high-velocity impact damage in advanced composites.

  • PDF

Monthly Variations of Surface Winds in the Korean Peninsula Sea Area and Typhoon Monitoring Using Microwave Remote Sensing (마이크로파 원격탐사에 의한 한반도 주변 해상풍의 월변동 특성 및 태풍 모니터링에 관한 연구)

  • Yang, Chan-Su;Jun, Ki-Cheon;Lehner, Susanne
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.201-204
    • /
    • 2006
  • 태풍의 경우, 주요 자연재해 중의 하나로 태풍의 상황을 정확하게 파악하는 것은 기상예측의 정도를 높이고, 재해를 방지하는데 중요한 역할을 할 수 있다. 일반적으로 태풍의 동향을 감시하는데 있어, MTSAT 등의 기상위성이 주로 활용되고 있다. 근년 인공위성의 원격탐사를 이용하여 광범위의 해양에 대한 해상풍과 파랑의 관측이 가능하게 되었다. 본 연구에서는, 2000년 QuickSCAT위성에 의한 해상풍의 월변동 특성을 조사하고, 7월에 한반도에 영향을 준 태풍 카이탁내의 해상풍을 검토하였다. 추가로 2005 년 8월 30일의 태풍 탈림에 대해서 ENVISAT ASAR Scan SAR에 의한 해상풍 추출을 시도하였다. QuickSCAT 에 의한 풍향을 이용한 방법과 SAR 자체의 패턴을 이용한 방법이 비교되었다.

  • PDF

Tensile Characterization of Ceramic Matrix Composites (CMCs) with Nondestructive Evaluation (NDE) Techniques

  • Kim, Jeongguk;Lee, Joon-Hyun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.190-194
    • /
    • 2003
  • Two different types of nondestructive evaluation (NDE) techniques were employed to investigate the tensile behavior of ceramic matrix composites (CMCs). Two NDE methods, ultrasonic testing (UT) and infrared (IR) thermography, were used to assess defects and/or damage evolution before and during mechanical testing. Prior to tensile testing, a UTC-scan and a xenon flash method were performed to obtain initial defect information in light of UT C-scans and thermal diffusivity maps, respectively. An IR camera was used for in-situ monitoring of progressive damages. The IR camera measured temperature changes during tensile testing. This paper has presented the feasibility of using NDE techniques to interpret structural performance of CMCs.

  • PDF

Low-velocity Impact Damdage Monitoring for Laminate Composite panels Using PVDF Sensor Signals and Acoustics Emission Signals (압전센서와 음향방출신호를 이용한 적층복합재 판재에 대한 저속 충격손상 모니터링)

  • Kim, Hyoung-Il;Kim, Jin-Won;Kim, In-Gul
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.27-30
    • /
    • 2005
  • This paper studied the PVDF(polyvinylidene fluoride) and Acoustic Emission sensors characteristics of the laminated composite panels under the low velocity impact. The various impact test by changing impact height is performed on the instrumented drop weight impact tester. The STFT(short time Fourier transform) and WT(wavelet transform) are used to decompose the each sensor signals. A ultrasonic C-scan and digital scope are used to define damaged area in each case. The test result indicated that the individual sensor signals involve the damage initiation and development.

  • PDF