• Title/Summary/Keyword: Monitoring Devices

Search Result 1,111, Processing Time 0.031 seconds

Development of remote monitoring system based on wire and wireless internet Environment (유.무선 인터넷 환경에 연동한 원격 감시시스템 개발)

  • 박상국
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.557-560
    • /
    • 2004
  • In this paper, wireless internet services are combined with conventional wire internet service system. These system support that instrument manager can be access his instrument by use personal mobile devices and instrument manager can be take emergency action by use mobile devices. for this, error signal of local instruments are transmitted to the serial port of local server through Rf wireless communication channel. Also, The image of local instruments are transmitted to the web monitoring screen of main server. Network Camera System Supports remote monitoring functions. The interfacing of nam server with external user are possible through the mobile devices.

  • PDF

Development of HIL Simulator for Control and Monitoring of Deep-Sea Miner (심해저 집광기의 제어.계측용 HIL 시뮬레이터 개발)

  • Park, Soung-Jea;Yeu, Tae-Kyeong;Hong, Sup;Kim, Byung-Yong;Kim, Sang-Bong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.319-322
    • /
    • 2006
  • The Deep-sea miner system is composed of body, actuators, sensors, and devices for control and monitoring. At present, we are manufacturing the miner's body included actuators and already consisted with off-the-shelf embedded controller. But sensors and those devices were just determined. To previously test performance of embedded controller which manages control and monitoring of miner system, its simulator must be developed for control and monitoring. Hardware-In-the-Loop(HIL) simulation is being increasingly used in industrial applications. This is an effective tool for the evaluation of electric system and drives. In the HIL simulator, we can test and design the control and monitoring system freely without the risk of hardware ruins and the load of expenses. Also the programming software for miner operating is verified on the HIL simulator. In this paper, we introduce the concept of HIL simulator for control and monitoring of deep-sea miner.

  • PDF

LonWorks-based Distributed Monitoring and Control for Predictive Maintenance (PM)

  • Park, Gi-Heung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.150.3-150
    • /
    • 2001
  • Requirements for Distributed Monitoring and Control Networks (DMCN) differ greatly from those of typical data networks. Specifically, any DMCN technology which employs a fieldbus protocol is different from If network protocol TCP/IP. In general, one needs to integrate fieldbus protocol and TCP/IP to realize DMCN over IP network or internet Interoperability between devices and equipments is essential to enhance the quality and the performance of predictive maintenance (PM). This paper suggests a basic framework for LonWorks-based DMCN over IP network and a method to guarantee interoperability between devices and equipments.

  • PDF

A Study on the Cognizance of Hospital and oriental Hospital Workers for Medical Device Safety Information Monitoring (의료기기 안전성 정보 모니터링에 대한 한병병원 및 병원 종사자의 인지도 조사연구)

  • Kim, Ji Hyun;Nam, Ki Chang;Kim, Hojun;Nam, Yeon Gyo;Kim, You Jin;jo, Eun hye;Kwon, Bum Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.86-93
    • /
    • 2021
  • Purpose: The purpose of this study is to find out the cognizance of medical device safety information (MDSI) monitoring in the hospital and oriental hospital workers, and the different aspect of MDSI between oriental medical devices and medical devices. Methods: The survey was performed both in the oriental medicine hospital and general hospital. The survey had 16 items; 2 items basic questions, 5 items in the awareness of MDSI, 5 items in the education of MDSI, 4 items in the necessity of defining oriental medical devices and differences between general and oriental medical devices. A total of 120 hospital worker were participated; 60 oriental medicine hospital workers and 60 general hospital workers. They had worked in the oriental medicine or general hospital associated with 'Medical Device Safety Monitoring Center, Dongguk University Ilsan Hospital' in 2019 and 2020. Results: The cognizance of MDSI was high both in oriental medicine hospital and general hospital workers and there were no significant differences between oriental medicine and general hospital workers. When we divided the hospital workers into the senior workers who had worked for over 3 years and junior workers for less than 3 years, the senior workers had higher awareness of MDSI than junior workers. However, the cognizance of education of MDSI was high which was not different between senior and junior workers. Both hospital workers thought that it was necessary to define oriental medicine device legally and the oriental medical device might have low risk and less side effect than medical device. Conclusion: The cognizance of MDSI was high and there was no significant differences between oriental medicine and general hospital workers. Because the senior hospital workers had higher recognition of MDSI, we need to provide the continuous education program for junior hospital workers. Although oriental medical device are thought to be safer than medical device, we need to have a legal definition.

The Study of the Peer-to-Peer Communication System for a UAV Navigational Monitoring Using a HSDPA (HSDPA를 이용한 무인항공기 항법 모니터링용 Peer-to-Peer 통신 시스템 구현 연구)

  • Kim, Ho-Gyun;Song, Jun-Beom;Song, Woo-Jin;Kang, Beom-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1025-1033
    • /
    • 2011
  • This paper presents a realization of a peer-to-peer communication system for a UAV navigational monitoring using a commercial HSDPA(High Speed Download Packet Access) mobile communication device. The realized system consists of a communication server, an air data terminal and multiple ground monitoring devices, where the server transfers navigational data from a UAV to multiple monitoring devices in real-time with commercial HSDPA modem. Through ground and flight tests, data were obtained to observe the realized system. Test results show that, depending on communicational environment, about 300msec delay, congestion and packet-loss between air data terminal and ground monitoring devices. Nevertheless, through high-speed long range test on a ground vehicle and altitude test with a UAV flight, the feasibility of a UAV navigational monitoring system was observed.

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

Algorithm of Analysing Electric Power Signal for Home Electric Power Monitoring in Non-Intrusive Way (가정용 전력 모니터링을 위한 전력신호 분석 알고리즘 개발)

  • Park, Sung-Wook;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.6
    • /
    • pp.679-685
    • /
    • 2011
  • This paper presents an algorithm identifying devices that generate observed mixed signals that are collected at main power-supply line. The proposed algorithm, which is necessary for low cost electric power monitoring system at appliance-level, that is non-intrusive load monitoring system, divides incoming mixed signal into multiple time intervals, calculating difference-signals between consecutive time interval, and identifies which device is operating at the time interval by analysing the difference-signals. Since the features of one device can remain when the time interval is short enough and the features are independent and additive, well-known classification algorithms can be used to classify the difference-signals with features of N individual devices, otherwise $2^N$ features might be necessary. The proposed algorithm was verified using data mixed in a laboratory with individual devices's data collected from field. When maximum 4 devices operate or stop sequentially and when features satisfy the requirements of proposed algorithm, the proposed algorithm resulted nearly 100% success rate under the constrained test condition. In order to apply the proposed algorithm in real world, the number devices shall increase, the time interval shall be smaller and the pattern of mixture shall be more diverse. However we can expect, if features used follow guidelines of proposed algorithm, future system could have certain level of performance without the guideline.

Reducing Standby Power Consumption System by Monitoring the AC Input Current for the AV Devices (AV 기기를 위한 AC 입력 전류 모니터링 대기 전력 저감 시스템)

  • Lee, Dae Sik;Yi, Kang Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1493-1496
    • /
    • 2016
  • This paper proposes a system for reducing the standby power consumption in using the consumer electronic devices such as a television, a home theater, a set-top box, or a DVD player. The system is consisted of a flyback converter, monitoring circuits, a relay and a micro-processor. The proposed system can reduce the standby power consumption by disconnecting the AC input and the consumer devices can be turned on with a remote control. The proposed standby power system consumes the low power to receive the infrared signal from the remote controller. Furthermore, a electronic double layer capacitor is used to store the energy with high efficiency. The proposed power system can operate the 플라이백 converter to charge the electronic double layer capacitor and connect the AC input to the consumer electronic devices. The proposed power circuit can reduce the standby power consumption in AV devices without increasing the cost. The prototype is implemented to verify the system with the commercialized products.

Development of a Non-contact Type Magnetic Signal Monitoring Equipment for Automotive Electric Devices (비접촉식 자동차 전장용 자기신호 측정 장치)

  • Yang, Hyong-Yeol;Yang, Seung-Hak
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.381-386
    • /
    • 2010
  • A non-contact type magnetic signal monitoring equipment for automotive electric devices is proposed in this paper. There are many kinds of actuators in the car like solenoid, relay, motor, injector, etc which are operated by magnetic energy. It is difficult to find out whether the actuators operate well or not because the terminals of the actuators are combined to the connectors. In this paper a non-contact type magnetic signal monitoring equipment using Hall effect sensor is proposed to measure the magnetic signal of the actuators very easily to find out the actuators' operating status. The simulation and experimental results show that the developed equipment is very useful and has good performance.

A Four-Layer Robust Storage in Cloud using Privacy Preserving Technique with Reliable Computational Intelligence in Fog-Edge

  • Nirmala, E.;Muthurajkumar, S.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3870-3884
    • /
    • 2020
  • The proposed framework of Four Layer Robust Storage in Cloud (FLRSC) architecture involves host server, local host and edge devices in addition to Virtual Machine Monitoring (VMM). The goal is to protect the privacy of stored data at edge devices. The computational intelligence (CI) part of our algorithm distributes blocks of data to three different layers by partially encoded and forwarded for decoding to the next layer using hash and greed Solomon algorithms. VMM monitoring uses snapshot algorithm to detect intrusion. The proposed system is compared with Tiang Wang method to validate efficiency of data transfer with security. Hence, security is proven against the indexed efficiency. It is an important study to integrate communication between local host software and nearer edge devices through different channels by verifying snapshot using lamport mechanism to ensure integrity and security at software level thereby reducing the latency. It also provides thorough knowledge and understanding about data communication at software level with VMM. The performance evaluation and feasibility study of security in FLRSC against three-layered approach is proven over 232 blocks of data with 98% accuracy. Practical implications and contributions to the growing knowledge base are highlighted along with directions for further research.