• 제목/요약/키워드: Monitoring Criteria

검색결과 582건 처리시간 0.026초

확률론적 평가를 이용한 원자력발전소 소내전력공급계통 신뢰도 감시 방법 (A Method to Monitor the Reliability of In-house Power Supply Systems in Nuclear Power Plants Based on Probabilistic Assessment)

  • 박진엽;정동욱
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.444-449
    • /
    • 2009
  • This paper introduces a method to establish performance criteria of the in-house power supply system in nuclear power plants. The performance criteria of the system is presented in terms of the number of function failures and amount of the out-of-service time that can be allowed commensurate with the probabilistic safety assessment results of the nuclear power plants. To obtain the performance criteria such as reliability and availability, the functions of the system were analyzed and probabilistic assessment results were utilized. This method provides quantitative guidelines in selecting and monitoring system functions to determine an adequate level of maintenance quality in order to ensure the probabilistic goals for the safety of the nuclear power plants.

국내 공동주택 부문의 친환경건축 인증 평가 항목 및 사례 분석 (The Analysis on the Evaluation Items of Korea Green Building Certification Criteria by the Case Studies of Collective Housing)

  • 김창성
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.93-100
    • /
    • 2013
  • Many countries have made their best to protect the earth from global warming and to find solutions for the reduction of carbon dioxide emittion and energy consumption. Especially, buildings have emitted over 40% of carbon dioxide against whole quantities emitted to the earth. Therefore, the reduction of carbon dioxide emitted from buildings require to save the earth environment. Energy consumption of buildings in Korea has reached 24% of total energy quantities, and energy consumption of collective housing has been continuously increasing. So, Korea government has also executed the Green Building Certification Criteria(GBCC). The GBCC evaluates the 8 types of buildings - collective housing, office, school, etc - to certificate the green building. In this paper, the evaluation items of collective housing in GBCC were reviewed to be used as the reference data for future revisions by the case studies. According to the results of this study, current version of GBCC requires additional revisions about the evaluations of energy consumption monitoring, commissioning and existing building.

상시 계측결과를 이용한 경부고속철도 교량의 동적거동 분석 (A analysis on dyanmic movements of Bridge status using High Rail monitoring systems)

  • 정재민;한상철;최일윤;이준석;서형렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.934-939
    • /
    • 2004
  • The Korea high-speed rail, based on the French design. It also implements new concept to increase the strength of bridge deck by adding an impact factor (dynamic intensity factor) in static load. In order to assure the dynamic stability, SYSTRA and Jeseph Penzien, a professor in CEC (the US) conducted a dynamic stability review on design phase. Analyzing the review results, they developed design criteria for dynamic behavior. This study deal with operating PSC box GIRDER equipped with measurement equipment or measured data of Seoul $\∼$ Taejeon, P.S.C BOX GIRDER bridge and steel comsition bridge equipped with measurement equipment based on structual knowledge about configuration of measuring sensor, response analysis of structure when train runs was performed by using measured data of PSC box girder to directly compare with design criteria. moreover, the dynamic stability with comparison of high-speed rail construction criteria was reviewed and analyzed based on historical records.

  • PDF

토양오염방지를 위한 지하저장탱크의 관리 방안 연구 (Management Criteria of Underground Strage Tank for Prevention of Soil Contamination)

  • 김준현;한영한
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

보로노이 기법과 밀도분석을 활용한 미세먼지 측정소 공간적 위치 문제 연구 (A Study on the Spatial Position Problem of PM Monitoring Stations Using Voronoi Technique and Density Analysis)

  • 정종철
    • 지적과 국토정보
    • /
    • 제48권2호
    • /
    • pp.185-195
    • /
    • 2018
  • 서울시에서 시민들이 사용하는 미세먼지 앱은 위치기반으로 자신의 위치에서 가장 가까운 측정소의 미세먼지 농도를 제공받는다. 현재 환경부에서 고려하는 미세먼지 측정망 선정 방법은 측정소의 분포 및 인구밀도를 고려한 방식과 지도상의 표현방식이 주 결정방법이나 인위적인 변수 및 다른 환경요인을 고려하지 않는다. 본 연구에서는 미세먼지 측정소와 행정동의 대표성을 보여주는 행정동 중심점을 활용하여 측정소와 동중심의 거리에 대해 분석하였으며, 측정값을 제공하는 측정소의 개수를 확인하였다. 또한 보로노이 알고리즘과 헥사곤 격자를 활용하여 각 측정소의 제공범위를 면적으로 나타내며 현 측정소의 공간적인 위치의 문제점을 지적하였다. 공간분석을 위한 환경변수는 단독주택, 공동주택, 제1종 근린생활권, 제2종 근린생활권, 쓰레기처리장, 위험물처리시설, 공장이며 분석결과로 만들어진 신규 측정소 위치는 기존의 환경부에서 제공하는 선정기준이 아닌 추가적인 변수를 고려한 선정기준을 제시하였다.

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Engineering Technology Far-end Telecontrol Cathodic Protection on the Structure of Jetty Bridge Cap Beams

  • Liu, Yi-Hsiung;Lim, Pau-Yee;Shih, Chien-Chis
    • Corrosion Science and Technology
    • /
    • 제2권1호
    • /
    • pp.47-52
    • /
    • 2003
  • 23 cap beams on the 1 Km length jetty bridge in Shin-da power plant (Taipower co., Taiwan) utilize far-end telecontrol cathodic protection technology which is the first case ever used in Taiwan. The system comprises cathodic protection system and te1econtrol monitoring system. The control and monitoring such as protection current adjustment, protection potential and depolarization measurement of the 23 cap beams can be adjusted through system telecontrol operations. Thereby allows monitoring and control of the 23 anode zones in a convenient and cost effective way. This system is at present still in its best running condition since Sept. 1997 when it was completed. All the 23 cap beams can achieve the 100 mV depolarization potential criteria of protection. It meet the specifications of reinforced concrete cathodic protection standard and proved to be very excellent.

2007년도 기상청 신설 및 이전 지진관측소의 배경잡음 특성 연구 (2007 Ambient noise levels study about new and moving seismic stations at KMA)

  • 전영수;남성태;신동훈;조범준
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2007
  • KMA established short period seismometer, accelerometer, and ocean bottom seismometer network to build the detail earthquake monitoring system and Tsunami monitoring system. KMA also replaced borehole seismometer and wave height meter monitoring system. The purposes of this study are to record the ambient seismic noise levels of short period seismometer and accelerometer installed in 2006 and 2007, and compare their characteristics to present the standard of site selection criteria.

  • PDF

운용중인 철도터널의 안전관리 시스템 시범구축 (Development of Safety Monitoring System for Operating Railway Tunnel)

  • 이수형;신민호;김현기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.73-78
    • /
    • 2008
  • There has been need for safety monitoring systems for the social infrastructures. These infrastructures are subject to degradation over time, reduced functionality, and loss of functionality as a result of factors such as a wide variety of installation environments, natural disasters, and nearby work. Therefore, it is necessary to perform appropriate inspections, repairs, and renovations to ensure safe and efficient maintenance and operation. This paper introduces the example of the development of the safety monitoring system for operating railway tunnel. Tunnel profile measuring system using laser beam, crack gauges, accelerometer and a pluviometer were implemented to monitor the safety of a deteriorated tunnel. The measured data were transferred through wireless network and analyzed in real time. The safety criteria for tunnel stabilities and train operations are also discussed.

  • PDF