• Title/Summary/Keyword: Monitoring Criteria

Search Result 583, Processing Time 0.027 seconds

Study of Performance Criteria Methodology for Maintenance Effectiveness Monitoring Program for Nuclear Power Plants (원전 정비효과성감시 프로그램의 성능기준설정 방법론 개선)

  • Song, Tae-Young;Yeom, Dong-Un;Hyun, Jin-Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.26-32
    • /
    • 2012
  • The systems of the nuclear power plant are designed based on the User Requirement Document, and Korea Hydro & Nuclear Power Co. (KHNP) implements preventive maintenance activities to keep the specific design function of the system consistently. To monitor the preventive maintenance effectiveness, KHNP has also developed maintenance effectiveness monitoring (MR) program based on NUMARC 93-01 since 2003, and has implemented the program in all operating plants. Recently, KHNP has upgraded MR programs by reflecting implementing experiences ; reestablishing the performance monitoring level, improving analysis for standby function and performance criteria for passive components, reestablishing the availability performance criteria and the performance criteria for the same type of components. These upgraded MR programs will contribute to enhance safety and improve equipment reliability through monitoring maintenance effectiveness.

Development of Monitoring Site Selection Criteria of the Korean Soil Quality Monitoring Network to Meet its Purposes (토양측정망 운영목적에 따른 토양측정망 지점 선정 방안 연구)

  • Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.2
    • /
    • pp.19-26
    • /
    • 2013
  • This study developed the classification of National Soil Quality Monitoring Network (NSQM) and its site selection criteria to meet the recently established purposes of the NSQM. The NSQM were suggested by this study to classify into the six-purposes site groups from the current classification of land uses. The six purposes site groups were 1) intensive observation sites, 2) contaminant loading sites, 3) human activity sites, 4) background sites, 5) river soil sites, and 6) sites near the groundwater quality monitoring wells. Furthermore, this study developed the site selection criteria of NSQM utilizing the accumulated NSQM data, road traffic data, chemical emission data, census, soil information, and the literature related to soil quality variation due to contaminant loads. For selecting suitable sites for NSQM, this study used road traffic, chemical emission, the distance from the contaminant sources, and population information as specific criteria. The suggested site classification and criteria were appled for the current 100 NSQM sites for evaluation. Forty sites were met to the criteria suggested by this study, but sixty sites were not met to the criteria. However, some of the sixty sites also included the obscure sites that their addresses were not apparent to find them.

Establishment of Alarm Criteria for Automatic Water Quality Monitoring System in Korea

  • Lim, Byung-Jin;Hong, Eun-Young;Kim, Hyun-Ook;Jeong, Eun-Sook;Heo, Woo-Myung;Kim, Yoon-Hee
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • As of September 2008,45 Automatic Water Quality Monitoring Systems (AWQMS) have been installed at different sites on the 4 rivers to detect early the presence of pollutants in water and to issue an alarm. We count the number of issuing alarms by AWQMS, however, we will find the alarm has hardly been issued. The reasons for the scarcity of alarm issue are extensively being examined. The National Institute of Environmental Research attributes wrong alarm criteria for each AWQMS station to one the reasons. In this study, a suggestion has been made to modify the current alarm criteria to correspond with characteristics of river water quality. The current system with only two criteria (low and high) should be replaced as four-criteria systems (low, medium, high, and severe) based on cases of other advanced countries and stream conditions of Korea. The highest value of data collected for 5 years was suggested as the alarm criteria for each parameter. Meanwhile the alarm criteria for VOCs, phenol and heavy metals were established as same as drinking water quality criteria.

Reliable monitoring of embankment dams with optimal selection of geotechnical instruments

  • Masoumi, Isa;Ahangari, Kaveh;Noorzad, Ali
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.1
    • /
    • pp.85-105
    • /
    • 2017
  • Monitoring is the most important part of the construction and operation of the embankment dams. Applied instruments in these dams should be determined based on dam requirements and specifications. Instruments selection considered as one of the most important steps of monitoring plan. Competent instruments selection for dams is very important, as inappropriate selection causes irreparable loss in critical condition. Lack of a systematic method for determining instruments has been considered as a problem for creating an efficient selection. Nowadays, decision making methods have been used widely in different sciences for optimal determination and selection. In this study, the Multi-Attribute Decision Making is applied by considering 9 criteria and categorisation of 8 groups of geotechnical instruments. Therefore, the Analytic Hierarchy Process and Multi-Criteria Optimisation and Compromise Solution methods are employed in order to determine the attributes' importance weights and to prioritise of instruments for embankment dams, respectively. This framework was applied for a rock fill with clay core dam. The results indicated that group decision making optimizes the selection and prioritisation of monitoring instruments for embankment dams, and selected instruments are reliable based on the dam specifications.

Driving behavior Analysis to Verify the Criteria of a Driver Monitoring System in a Conditional Autonomous Vehicle - Part I - (부분 자율주행자동차의 운전자 모니터링 시스템 안전기준 검증을 위한 운전 행동 분석 -1부-)

  • Son, Joonwoo;Park, Myoungouk
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • This study aimed to verify the criteria of the driver monitoring systems proposed by UNECE ACSF informal working group and the ministry of land, infrastructure, and transport of South Korea using driving behavior data. In order to verify the criteria, we investigated the safety regulations of driver monitoring systems in a conditional autonomous vehicle and found that the driver monitoring measures were related to eye blinks times, head movements, and eye closed duration. Thus, we took two different experimental data including real-world driving and simulator-based drowsy driving behaviors in previous studies. The real-world driving data were used for analyzing blink times and head movement intervals, and the drowsiness data were used for eye closed duration. In the real-world driving study, 52 drivers drove approximately 11.0 km of rural road (about 20 min), 7.9 km of urban road (about 25 min), and 20.8 km of highway (about 20 min). The results suggested that the appropriate number of blinks during the last 60 seconds was 4 times, and the head movement interval was 35 seconds. The results from drowsy driving data will be presented in another paper - part 2.

Driving behavior Analysis to Verify the Criteria of a Driver Monitoring System in a Conditional Autonomous Vehicle - Part II - (부분 자율주행자동차의 운전자 모니터링 시스템 안전기준 검증을 위한 운전 행동 분석 -2부-)

  • Son, Joonwoo;Park, Myoungouk
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • This study aimed to verify the criteria of the driver monitoring systems proposed by UNECE ACSF informal working group and the ministry of land, infrastructure, and transport of South Korea using driving behavior data. In order to verify the criteria, we investigated the safety regulations of driver monitoring systems in a conditional autonomous vehicle and found that the driver monitoring measures were related to eye blinks times, head movements, and eye closed duration. Thus, we took two different experimental data including real-world driving and simulator-based drowsy driving behaviors in previous studies. The real-world driving data were used for analyzing blink times and head movement intervals, and the drowsiness data were used for eye closed duration. In the drowsy driving study, 10 drivers drove approximately 37 km of a monotonous highway (about 22 min) twice. The results suggested that the appropriate duration of eyes continuously closed was 4 seconds. The results from real-world driving data were presented in the other paper - part 1.

Improvement of Domestic Design Criteria of Tunnel Maintenance Monitoring and Latest Technology Trend (터널 유지관리 계측의 국내설계기준 개선 및 최신 기술동향)

  • Baek, Kyung Jong;Kwon, Young Eok
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.9-16
    • /
    • 2014
  • Though the maintenance monitoring of structurally weak parts of the tunnel structure in public service must be judged in connection with the monitoring during the construction period for analysis of the behavior of the ground and surrounding structures following the tunnel excavation for the effective management, the monitoring during the construction period and the maintenance monitoring are implemented separately on the basis of the periods of construction and maintenance, so the connectivity and systematic management of the related data are mostly inadequate. The improvement direction is suggested in this thesis, by analyzing the problems of tunnel monitoring in the domestic design criteria. And, it is anticipated that from now on the use of hi-tech sensors and wireless communications technology will proceed vigorously in the maintenance, so considering these situations, the development and application of the maintenance monitoring system and the revision of the domestic design criteria and specification are needed in the future.

Field Test of On-line Monitoring System for Oil-filled Power Transformers (대용량 유입변압기의 온라인 진단시스템 적용연구)

  • Lee, Chang-R.;Kim, Yong-H.;Kim, Nam-H.;Kim, Jung-H.;Yoon, Ja-H.;Nam, Keuk-C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1644-1646
    • /
    • 2003
  • This paper presents recent studies on the on-line insulation monitoring and diagnostic systems for transformers developed by HHI. Sufficiently high sensitivity and accuracy for practical use were achieved for the system, combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

A study on field test of diagnostic Monitoring System for Power Transformers (전력용 변압기 예방진단 시스템의 실 계통 적용 연구)

  • Kim, Y.H.;Lee, C.R.;HwangBo, S.W.;Shin, Y.T.;Park, G.C.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

The Study for Establishing the Criteria of Measurement Items in the Monitoring System for the Steel-Box Girder Bridge by FEM Analysis (구조해석에 의한 강상자형교 상시계측시스템 계측항목별 관리기준치 설정 연구)

  • Joo, Bong-Chul;Park, Ki-Tae;You, Young-Jun;Lee, Chin-Hyung;Hwang, Yoon-Koog
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.35-41
    • /
    • 2009
  • If any bridge has the monitoring system, the bridge manager can check the history of bridge behavior and the progress of the damage more exactly. When the unexpected event (ex: earthquake and flood) happens, the manager can check the safety condition of the bridge and make the pertinent action for bridge management which is reduction of vehicle speed or traffic control through the system. Additionary the manager can make the well-timed repair or reinforcement through the system, so he can save the management cost or the life cycle cost. This study presents the method of setting the criteria by FEM analysis in bridge monitoring system, and the standard progress for setting the criteria about measurement items of monitoring system for the steel box type bridge.

  • PDF