• Title/Summary/Keyword: Monitor

Search Result 7,341, Processing Time 0.035 seconds

Investigation of the Performance Characteristics of an In-Situ Particle Monitor at Low Pressures Using Aerodynamic Lenses (저압상태에서 공기역학적 렌즈를 이용한 In-Situ Particle Monitor의 성능특성 분석)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1359-1367
    • /
    • 2000
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at low pressures has been studied. We generated the uniform sized methylene blue particle beams using three identical aerodynamic lenses in the center of the vacuum line, and measured the detection efficiency of the ISPM. The effects of particle size, particle concentration, mass flow rate, system pressure, and arrangement of aerodynamic lenses on the detection efficiency of the ISPM were examined. Results show that the detection efficiency of the ISPM greatly depends on the mass flow rate, and the particle Stokes number. We also found that the optimum Stokes number ranges from 0.4 to 1.9 for the experimental conditions.

Seasonal Variation of Cosmic Ray Intensity Observed by the Oulu Neutron Monitor

  • Jeong, Jaesik;Oh, Suyeon
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2020
  • Muons and neutrons are representative secondary particles that are generated by interactions between primary cosmic ray particles (mostly protons) and the nuclei of atmospheric gas compounds. Previous studies reported that muons experience seasonal variations because of the meteorological effects of temperature. The intensity of neutrons has a typical modulation with various periods and reasons, such as diurnal and solar variation or transient events. This paper reports that cosmic ray particles, which were observed by neutron monitors, have seasonal variations using the daily data at the Oulu neutron monitor. To eliminate the effects of solar activity across time, the daily data were normalized by two different transformations: transformations with respect to the grand mean and yearly mean. The data after transformation with respect to the yearly mean showed more statistical stability and clear seasonal variations. On the other hand, it is difficult to determine if the seasonal variation results from terrestrial effects, such as meteorological factors, or extraterrestrial effects, such as the position of the Earth in its orbit of revolution.

Development of Sensor Based Energy Management System (센서기반 에너지 모니터링 프로토타입 시스템)

  • Um, Dae-Jin;Choi, Jung-In;Lee, Ingyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.69-74
    • /
    • 2014
  • With the increasing interest of energy efficiency, several buildings and factories begin to monitor energy usages with a built-in energy management system. However, the built-in energy monitoring system does not reflect the dynamics of buildings and factories energy usage. To overcome the latter, we deploy several sensors to monitor the dynamics of buildings energy usage patterns. In this paper, we are proposing a framework of a sensor based energy monitoring system. Based on our limited experiments, we can monitor power usages by a person, device and time period. As a result, we can plan a better energy usage and improve energy efficiency by the monitored energy usage profile data.

Development of Portable Arrhythmia Monitor Using Microcomputer ( II ) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(II))

  • Lee, Myoung-Ho;Ahn, Ja-Bong;Park, Jang-Choon
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.351-360
    • /
    • 1989
  • This paper describes the design of portable arrhythmia monitor and associated algorithm for automated diagnosis based-on microcomputer in the ambulatory ECG recording, analysis, and transmitting to a hospital host computer immediately through the telephone system. The device differs from Molter recorder in that it does not store normal ECG signals but captures and alarms the ECG during suspected abnormal periods and selected temporal epochs to a central hospital site. This porta file arrhythmia monitor makes use of a general purpose computer and software will be changed to meet the custom requirements of individual physicians and patients. At present it is very obvious that each cardiologist has his own method of analyzing ECG recordings and utilizes past experience more than the firm quantitative analysis of data.

  • PDF

Method for Maneuver Monitoring with Vehicle Trajectory Reconstruction (차량 궤적 추정을 통한 운행 안전 모니터링 기법)

  • Heo, Geun Sub;Lee, Sang Ryong;Shin, Jin-Ho;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.1065-1071
    • /
    • 2012
  • In this paper, we proposed a method for vehicle monitoring with trajectory reconstruction. For safety, it is important to monitor the driving habit of driver. Every year, many accidents occur due to the reckless driving of the driver. Continuous monitoring of the status of commercial vehicles is needed for safety through the entire path from start point to the destination. To monitor the reckless driving, we try to monitor the trajectory of the vehicle by using vehicle's lateral acceleration data. Compared with steering angle and lateral acceleration, these resemble each other. So, we find the relationship of steering angle and acceleration, and find the global direction of vehicle. We find the position of non-GPS section with EKF (External Kalman Filter) and reconstruct the whole trajectory during vehicle driving.

Future Trend and Status of LCD OEM/ODM Operating Model

  • Pan, Po-Chuan;Koo, Horng-Show
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.858-862
    • /
    • 2005
  • The industry of LCD monitor and LCD/TV production is complicate, so there are several OEM/ODM companies concentrated on technical and professional skills. Brand name company establishes its own brand name, sells its own product, and reflects market request. Therefore, the main duty of brand name company is on sales and marketing. This article explains the operating flow on LCD monitor and LCD/TV industry, operating relationship between brand name company and OEM/ODM, and advantage and disadvantage on different points. Furthermore, future trend of LCD monitor and LCD/TV can be reviewed in the article.

  • PDF

A Study of Gas-Assisted Injection Molding of 17" Flat Monitor Front Cover (17" 평면 모니터 Front Cover의 가스사출성형에 관한 연구)

  • Kim, Hong-Seok;Son, Jung-Sik;Seo, Tae-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.766-771
    • /
    • 2001
  • Gas-assisted injection molding is an innovative low-pressure injection molding technique that can provide numerous benefits such as reduced part warpage, excellent surface quality without sink marks, low injection pressure, and greater design flexibility. However, the adoption of gas-assisted injection molding may cause unexpected defects if the gas channel design is not conducted properly. The objective of this paper is to broaden the understanding of gas-assisted injection molding by summarizing the design procedures and experimental results of the gas-assisted injection molding of a 17" flat monitor front cover. The gas channels were designed by using Moldflow(MF/GAS) simulations and a 450 ton injection molding machine with a 5 stage pressure control gas kit was used in the experiments.

  • PDF

Monitoring of Ship's Emergency Lighting System using PLM(SELP) (PLM을 이용한 선박 비상조명시스템의 모니터링)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Baek, Young-Jin;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.105-106
    • /
    • 2006
  • In this paper we describe a driving, control and monitor of ship's emergency lighting system using power line modem.(PLM). Through this paper, experiment confirms that ON-OFF control of multiple SELP, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PLM communication.

  • PDF

Speed Sensorless Torque Monitoring of Induction Spindle Motor using Graphical Programming (그래픽 프로그래밍 기법을 이용한 주축용 유도전동기의 속도 센서리스 토크감시)

  • Park, Jin-U;Gwon, Won-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.107-113
    • /
    • 2002
  • To monitor the torque of an induction motor using current, rotating speed has been measured and used to calculate the slip angular velocity. Additional sensor, however, can cause extra expense and trouble. In this paper, a new algorithm is proposed to monitor the torque of vector controlled induction motor without any speed measuring sensor. Only stator current is measured to estimate the magnetizing current which is used to calculate flux linkage, rotor velocity and motor torque. Graphical programming is used to implement the suggested algorithm and to monitor the torque of an induction motor in real time. To solve the fluctuation problem of estimated torque caused from instantly varying rotating speed of an induction motor, the rotating speed is reconstructed based on the measured current signals. From several experiments, the proposed method shows a good estimation of the motor torque under the normal rotational speed.

Monitoring of Mechanical Seal Failure with Artificial Neural Network (신경회로망을 이용한 미케니컬 실의 이상상태 감시)

  • Lee, W.K.;Lim, S.J.;Namgung, S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.12
    • /
    • pp.30-37
    • /
    • 1995
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are gengrally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage,fast and severe wear, excessive torque, and squeaking results in big problems. To monitor the failure of mechanical seals and to propose the proper monitoring techniques with artificial neural network, sliding wear experiments were conducted. Torque and temperature of the mechanical seals were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. During the experiment, the variation of torque and temperature that meant an abnormal phenomenon, was observed. That experimental data recorded were applied to the developed monitoring system with artificial neural network. This study concludes that torque and temperature of mechanical seals wil be used to identify and to monitor the condition of sliding motion of mechanical seals. An availability to monitor the mechanical seal failure with artificial neural network was confirmed.

  • PDF