• 제목/요약/키워드: Momentum loss

검색결과 127건 처리시간 0.024초

BEMT를 적용한 20kW 수평축 풍력터빈 형상설계 및 성능해석 (A Study on the Configuration Design and the Performance Analysis of the 20kW HAWT based on BEMT)

  • 강호근;남청도;이영호;김범석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.669-676
    • /
    • 2006
  • The optimum design and the performance analysis software called POSEIDON for the HAWT (Horizontal Axis Wind Turbine) is developed by use of BEMT, which is the standard computational technique for prediction of power curves of wind turbines. The Prandtl's tip loss theory is adopted to consider the blade tip loss. The lift and the drag coefficient of S-809 airfoil are predicted via X-FOIL and the post stall characteristics of S-809 also are estimated by the Viterna's equations.$^{[13]}$ All the predicted aerodynamic characteristics are fairly well agreed with the wind tunnel test results. performed by Sommers in Delft university of technology. The rated power of the testing rotor is 20kW(FIL-20) at design conditions. The experimental aerodynamic parameters and the X-FOIL data are used for the power Prediction of the FIL-20 respectively The comparison results shows good agreement in power prediction.

좁은 채널 내의 대향분류 메탄-공기 비예혼합 화염의 거동 특성 (Behavioral Characteristics of the Non-Premixed Methane-Air Flame Oppositely Injected in a Narrow Channel)

  • 윤영민;이민정;조상문;김남일
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.264-271
    • /
    • 2009
  • Characteristics of a counter flowing diffusion flame, which is formulated by an oppositely-injected methane-jet flow in a narrow channel of a uniform air flow. The location of the flame fronts and the flame lengths were compared by changing the flow rates of fuel. To distinguish the effects of the narrow channel on the diffusion flame, a numerical simulation for an ideal two-dimensional flame was conducted. Overall trends of the flame behavior were similar in both numerical and experimental results. With the increase of the ratio of jet velocity to air velocity flame front moved farther upstream. It is thought that the flow re-direction in the channel suppresses fuel momentum more significantly due to the higher temperature and increased viscosity of burned gas. Actual flames in a narrow channel suffer heat loss to the ambient and it has finite length of diffusion flame in contrast to the numerical results of infinite flame length. Thus a convective heat loss was additionally employed in numerical simulation and closer results were obtained. These results can be used as basic data in development of a small combustor of a nonpremixed flame.

축류회전차 익말단 틈새유동에 대한 수치해석

  • 노수혁;조강래
    • 대한기계학회논문집B
    • /
    • 제22권3호
    • /
    • pp.336-345
    • /
    • 1998
  • The substantial loss behind axial flow rotor was generated by wake, various vortices in the hub region and the leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip was one of the main causes of the reduction of performance, the generation of noise and the aerodynamic vibration in rotor downstream. In this study, the three-dimensional flowfields in an axial flow rotor for various tip clearances were calculated, and the numerical results were compared with the experimental ones. The numerical technique was based on SIMPLE algorithm using standard k-.epsilon. model (WFM). Through calculations, the effects of the tip clearance on the overall performance of rotor and the loss distributions, and the increase in the displacement, momentum, and blade-force-deficit thickness of the casing wall boundary layer were investigated. The mass-averaged flow variables behind rotor agreed well with the experimental results. The presence of the tip leakage vortex behind rotor was described well. Although the loci of leakage vortex by calculation showed some differences compared with the experimental results, its behavior for various tip clearances was clarified by examining the loci of vortex center.

OMACON형 LM-MHD 시스템에서의 에너지전환특성 시뮬레이션 (Simulation of Energy Conversion Characteristics of OMACON LM-MHD Systems)

  • 김창녕
    • 한국시뮬레이션학회논문지
    • /
    • 제6권2호
    • /
    • pp.1-14
    • /
    • 1997
  • The characteristics of the flow and energy conversion in OMACON liquid-metal MHD system are investigated. Numerical simulation of two-phase flow in the OMACON system without magnetic field was carried out by the Phoenics code and the energy conversion characteristics are studied in association with the fact that the mechanical energy loss at the nozzle of the OMACON system are to be converted into electrical energy. In this system, working fluid (gas) is injected through the mixer located at the bottom of the riser, and is mixed with hot liquid metal. Therefore in the riser two-phase flow is developed under the influence of the gravity. In this study, the interaction between the gas and liquid is considered by the use of IPSA(InterPhase Slip Algorithm) where standard drag coefficient has been used. It has been assumed that in the flow regime the liquid is continuous and the gas is dispersed. For the liquid and gas, the continuity equations, momentum equations and energy equations are solved respectively in association with void fraction in the flow field. In order to calculate the energy conversion efficiency, firstly the ratio of the mechanical energy loss of liquid metal flow at the nozzle to the input thermal energy is considered. Secondly flow pattern of liquid metal in the generator has been analyzed, and the characteristics of the conversion of the mechanical energy into the electrical energy has been investigated. For an representative case where Hartmann number is 540 and magnetic field is 0.35 T, the present analysis shows that the energy conversion efficiency is 0.653. This result is considered to be reasonable in comparison with published experimental results.

  • PDF

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connect in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.63-68
    • /
    • 2002
  • ADC(Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation makes leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

  • PDF

Tracing the growth of the supermassive black holes with halo mergers

  • Byeon, Woowon;Kim, Juhan;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.47.1-47.1
    • /
    • 2015
  • The formation mechanism of supermassive black holes (SMBHs) at the center of galaxies remains an open fundamental question. Black holes (BHs) are believed to grow by accretion of gas or by merging with other BHs. Motivated by the observation of luminous quasar around redshift z ~ 7 with SMBH mass up to 109 solar mass, we follow the growth of the early assembly of SMBHs that trace the hierarchical evolution of dark matter halos derived from large cosmological simulations. The initial masses of BH seeds in the first halos were set up according to the BH mass - halo mass relation. We assume that mergers of host galaxies cause loss of angular momentum of gas and trigger episodes of gas accretion onto BHs for available durations and at the end of each episode of accretion, BHs merge immediately. We trace the evolution of BH masses for various scenarios for central gas properties in halos. We estimate the BH to halo mass ratio and BH mass function at each redshift.

  • PDF

스위치드-티 감쇠기를 이용한 초광대역 MMIC 디지털 감쇠기 설계 (Design of Ultra Wide Band MMIC Digital Attenuator using Switched-T Attenuator)

  • 주인권;염인복
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.39-44
    • /
    • 2005
  • A broadband DC to 40 GHz 5-bit MMIC digital attenuator has been developed. The ultra broadband attenuator has been achieved by newly inserted the transmission lines in conventional Switched-T attenuator and the optimization of the transmission line parameters. Momentum was employed in design for an accurate performance prediction at high frequencies and Monte Carlo analysis was applied to verify performance stability against the MMIC process variation. The attenuator has been fabricated with 0.15 $\mu$m GaAs pHEMT process. This attenuator has 1 dB resolution and 23 dB dynamic range. High attenuation accuracy has been achieved over all attenuation range and full 40 GHz bandwidth with the reference state insertion loss of less than 6 dB at 20 GHz. The input and output return losses of the attenuator are better than 14 dB over all attenuation states and frequencies.

  • PDF

자동차 냉각장치를 통하는 유동에 의한 항력 변화 예측 (Prediction of drag increase due to flow through automobile's cooling system)

  • 최도형;이응호
    • 오토저널
    • /
    • 제14권5호
    • /
    • pp.128-135
    • /
    • 1992
  • Using a commercial flow-analysis code VSAERO, a method to predict the drag of an automobile induced by the intake air of the cooling system has been devised. Given the pressure loss coefficient across the radiator, which varies with the radiator shape and the local Re, a simplified model of the internal flow is coupled with VSAERO to find the mass-flow rate through the car. The flow rate is obtained iteratively and that, in turn, gives the drag associated with this flow, which essentially is the momentum carried by the drained air. The results of a few sample cases are presented for two front-end shapes in combination with varying radiator frontal area.

  • PDF

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connector in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.23-28
    • /
    • 2003
  • ADC (Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation make a leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested, and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

사이드채널형 연료펌프의 성능예측 (Performance Prediction of Side Channel Type Fuel Pump)

  • 최영석;이경용;강신형
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.29-33
    • /
    • 2003
  • The periphery pump (or regenerative pump) has been generally applied in the automotive fuel pump due to their low specific speed (high heads and small flow rate) with stable performance curves. In this study, the performance prediction of side channel type periphery pumps has been developed. The prediction of the circulatory flow rate is based on the consideration of the centrifugal force field in the side-channel and in the impeller vane grooves. For the determination of performance curve (head-flow rate), momentum exchange theory is used. The effects of various geometric parameters and loss coefficients used in the performance prediction method on the head and efficiency are discussed, and the results were compared with experimental data.