Development of Leakage-free Automatic Discharge Connect in a Submersible Pump.

수중펌프의 Leakage-free 자동탈착장치 개발

  • 최영석 (한국생산기술연구원 신에너지환경팀) ;
  • 이경용 (한국기술교육대 대학원 한국생산기술연구원) ;
  • 이창한 (금정공업주식회사 기술연구소) ;
  • 이종훈 (금정공업주식회사 기술연구소)
  • Published : 2002.12.01

Abstract

ADC(Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation makes leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.