• 제목/요약/키워드: Moldflow analysis

검색결과 64건 처리시간 0.022초

유리인서트 사출금형 설계를 위한 사출성형 및 구조해석 (Injection molding and structure analysis for design of glass insert injection mold)

  • 문영배;고보선;정영득
    • Design & Manufacturing
    • /
    • 제2권3호
    • /
    • pp.6-9
    • /
    • 2008
  • This paper describes the process of structure analysis and injection molding analysis to manufacture the forming injection dies for huge glass insert. Factors such as filling time, filling pressure, material temperature, shrinkage, warpage were investigated by using the analysis software, Moldflow. Runner system and cavity structure were designed and manufactured through the results of deformation analysis data for glass insert. Filling time and filling pressure were analyzed in 3.756sec and 43.37MPa.

  • PDF

고형상비를 갖는 플라스틱제품의 냉각해석에 관한 연구 (A study on the cooling analysis of plastic products with high aspect ratio)

  • 황시현;서기영;김철규;김명기;지성대;정영득
    • Design & Manufacturing
    • /
    • 제2권2호
    • /
    • pp.6-9
    • /
    • 2008
  • Injection molding is representative process of plastic production. Most of numerical analyses for injection molding have been based on the Hele Shaw's approximation: two-dimensional flow analysis. The present work covers numerical analyses of injection molding using three-dimensional solid elements. The accuracy of the analysis results has been verified through some numerical examples in comparison with the various conditions. In this study, moldflow software was used to analyze the cooling analysis. The results of cooling analysis and testing catapult were compared for plastic products.

  • PDF

비대칭형 플라스틱 팬 제품 개발 (Development of Asymmetric Plastic Fan Product)

  • 연규현;김형국
    • 한국기계가공학회지
    • /
    • 제8권2호
    • /
    • pp.53-59
    • /
    • 2009
  • The analysis of injection molding process by CAE is widely used in development of plastic products. That comes from the fact that CAE analysis can reduce trial and error based on optimized design. On this study, by use of MOLDFLOW, the causes of product defects were found and solved by trade-off study. CAE analysis includes Flow-Cool-Warpage Analyses and finally a new mold-die design with better product quality was suggested. On injection molding of round-shaped plastic fan, new mold-die system with 4-tunnel gates located on the edge of a fan disc shows better quality rather than pin-point gate located on the center of a disc. That was effective in terms of flow mark removal and flatness improvement of the product.

  • PDF

3차원 입체요소를 사용한 정밀 전자부품의 사출성형 해석 (Numerical Analysis for Injection Molding of Precision Electronics Parts Using Three-Dimensional Solid Elements)

  • 박근;박제현;최상련
    • 소성∙가공
    • /
    • 제11권5호
    • /
    • pp.414-422
    • /
    • 2002
  • Most of numerical analyses for injection molding have been based on the Hele Shaw's approximation: two-dimensional flow analysis. In some cases, that approximation causes significant errors due to loss of geometrical information as well as simplification of the flow characteristics along the thickness direction. The present work covers numerical analyses of injection molding using three-dimensional solid elements. The accuracy of the analysis results has been verified through some numerical examples in comparison with the classical shell-based approach. The Proposed approach is then applied to predict product defects and to improve flow characteristics for a precision electronics part. In addition, design of experiment has been utilized in order to find the optimal process conditions for better product quality.

CAP 금형의 사출성형공정에 대한 해석 (Analysis of Injection Molding Process for CAP Mold)

  • 신장순;오상륜;허영무;윤길상;김유진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.23-27
    • /
    • 2005
  • Generally, when the injection molds are made in advanced nations, the improvement of a quality and production rate is obtained by using CAE. In this paper, the methodology which is possible to reduce the cycle time of injection molding process is studies by using the cooling analysis with CAE(Moldmax). In case of changing the cooling system design with the analysis result of CAE, the manimum reduction of the cycle time runs into 30 percent. Finally, the average reduction of the cycle time is 17.8 percent.

  • PDF

충격 흡수기 피스톤의 대체 개발에 관한 기초적 연구 (A Basic Study on the Alternative Development of Piston for Shock Absorber)

  • 김영호;배원명;임동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.121-124
    • /
    • 1995
  • This study is aimed at cutting down the cost, weight and improving process by replacing the traditional sintered piston of the shock absorber with engineering plastic piston by means of injection molding. To obtain the high mechanical properties, glass fiber material was selected adequately and forming analysis considering fiber orientation was made to remove the forming deficit fators and to construct the optimal runner system. In addition, structural analysis using commercial software MOLDFLOW was performed under near conditions in actual driving of automotive. The results from the internal pressure process test, oilproof test based on forming, structural and strength analysis shows that hydraulic close performance and damping force considering the out of roundness of shock absorber are relatively good.

  • PDF

사출성형 CAE 프로그램을 이용한 코어 휨의 예측 (Prediction of Core Shift using Injection Molding CAE program)

  • 문정연;곽민혁;박태원;정영득
    • Design & Manufacturing
    • /
    • 제8권2호
    • /
    • pp.7-11
    • /
    • 2014
  • The Core-Shift is often generated on injection mold which have thin and long core. And Core-Shift brings out problems for thickness variation and product ejecting process. In this study, analysis of Core-Shift was performed according to change of materials of core(steel P-20, Be-Cu) and various polymers(PP, PC) by using MoldFolw MPI 6.1 which is commercial injection molding analysis program. As the results of analysis, the magnitude of Core-Shift was increased as being use polymer had lower fluidity and lower rigidity core. In the future, we will study the relationship between amount of Core-Shift and ejecting force.

  • PDF

방열체 일체형 구조의 LED 아웃도어 등기구 상부커버에 관한 사출성형해석 (Injection molding analysis for LED outdoor lighting top cover of one heat sink body type structure)

  • 이관영
    • Design & Manufacturing
    • /
    • 제14권2호
    • /
    • pp.42-48
    • /
    • 2020
  • This study is on the injection molding analysis for the LED outdoor lighting top cover of one heat sink body type structure. Thermoplastic and thermosetting resins were applied to compare the thermal properties during the injection molding process. The thermoplastic resin is used in this study due to special characteristics that it is light, good strength and dose long not transmute quality even if pass long time. The thermosetting resin is applied to this study due to good in strength, lightweight and excellent etc, thermal conductivity. This study presented a preliminary analysis of fill time, weld line, air trap etc. for the injection molding process of LED lamp cover and body through simulation using Moldflow. As a result of the study, it was selected HTM-102 material because the thermosetting resin has excellent strength and heat conductivity.

혈당 측정을 위한 채혈기구 메인 샤프트의 사출성형 시뮬레이션 및 시 사출에 관한 연구 (A study on the blood collecting device of main shaft injection molding for measuring blood glucose by CAE analysis)

  • 백승엽
    • Design & Manufacturing
    • /
    • 제12권2호
    • /
    • pp.57-62
    • /
    • 2018
  • In diabetics, daily blood glucose testing is generally required at home, and thus, performing blood collection several times a day using a blood line is essential. Blood collection in the home and in the hospital is a source of pain and is the second most common cause of infection. In blood collecting device generally consists of four major parts: inner-case, outer case, main shaft and triger, and the most import part among those for necessary functionality is the main shaft. Filling time and injection pressure, filling balance, strain-rate analysis of change based on availability of the product. The Moldflow of FEM simulation is used for the analysis of injection molding process. In this study, aims to create a technique for injection molding and manufacturing of a main shaft of a high-performance blood-collecting apparatus capable of automatically extracting a lancet to relieve pain through depth control of the lancet.

PEI계 플라스틱 축대칭 부품의 사출 성형에 관한 연구 (Injection Moulding of Polyetherimide Axi-Symmetric Elements)

  • 하영욱;정태형;이범재
    • 한국공작기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.68-74
    • /
    • 2002
  • This research covers the development of axi-symmetric plastic elements for injection molding with insert steel such as high stiffness Sabot. The functional requirements of sabot are concentricity and fracture resistance about vertical and horizontal forces. For these, an analysis of characteristics of PEI(polyetherimide) polymer is performed by standard test specimen with accordance of ASTM test guidance. Moldflow analysis and simulation of injection molding process are carried out in order not only to estimate of the warpage but also to predict the characteristics of residual stresses which both product and structure of mold may have. A new vertical side injection machine and transverse mold have been constructed. Results of the measuring concentricity and fracture test after molding of sabot are satisfied to design specification over Cp $ratio{\geq}1.33$. Finally, this technique needs more research application to others axi-symmetric elements having different radius with insert steel md structure analysis from now on.