• 제목/요약/키워드: Mold Transformer

검색결과 67건 처리시간 0.03초

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Pole Mold transformer)

  • 조한구;이운용;한세원;김석수
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The one body molding model (Model 1) and air duct model (Model 2) are designed and their temperature distribution are analysed. The temperature rise value is about 105.5 deg in the model 1 and 65.28 de in the model 2. The temperature change of secondary winding is more than primary winding according to load ratio. The concentration part of Von Mises Stress occurs at interface between glass fiber and epoxy.

  • PDF

에폭시 몰드형 BCT의 절연열화 특성 (Characteristics of Insulation Degradation in Epoxy Mold Type BCT)

  • 송재주;이정철;임성훈;고석철;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

몰드변압기용 절연재료의 열적 수명진단을 위한 평가법 연구 (A Study on the Evaluation Method for Thermal Lifetime Diagnosis of Insulating Material for Mold Transformer)

  • 정재원;박홍태;오일성;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1000-1002
    • /
    • 1999
  • In this study, we were developed to provide a method for evaluating insulation systems for mold transformers with high-voltage ratings greater than 600V, in order to establish a uniform method for determining the temperature classification of mold transformer insulation system by testing rather than by chemical composition. Since these procedures are considered to be new, and have been tested exhaustively, further testing may prove the need for future revisions.

  • PDF

몰드변압기 소음저감을 위한 진동특성 파악 (The vibration characteristics for noise reduction of mold transformer)

  • 김기원;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.49-53
    • /
    • 2008
  • This study deals a way to reduce the transformer noises. The first step is to identify the source of the transformer noises. The second step is obtaining the vibration characteristics of transformer; its natural frequencies and mode shapes. Based on these information, an method to reduce the vibration of transformer can be found. The cause of transformer noises is mainly due to the magnetostrictive vibration of a core which is made of ferromagnetic substances. It is well known that the magnetostrictive vibration of a core is unavoidable, and a way to reduce the transformer noise by structural design is needed. It requires understanding the vibration characteristics. The natural frequencies and the mode shapes of transformer are analyzed by performing the modal testing.

  • PDF

몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석 (Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer)

  • 김지호;이향범;손진근
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

2[MVA] 배전용 몰드변압기의 글라스넷 형상 최적설계 (Optimum Design of Glass Net in 2[MVA] Mold Transformer)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.107-112
    • /
    • 2011
  • In this paper, the optimum design of the glass net shape was studied to minimize the electric field of mold transformer. The glass net is used for reinforcement in structure between coils and epoxy, but it can cause to increase the electric field and the partial discharge. Therefore, the optimum design of glass net is required to minimize the electric field. In this paper, the objective function was approximated by using response surface method and then Zoom-in method was used for optimal design to minimize the electric field. The electric field was analysed using finite element method for each shape of glass nets.

옥외 주상용 몰드 변압기인 적용 기술 (The Applied Technology of Mold Transformer for Outdoor Use)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.23-28
    • /
    • 2000
  • Insulator systems using resin casting apparatus are useful to realize the high capacity, small size, and combined electric power equipments, and are expected to bring various advantages. In Korea, epoxy resin molded apparatus have been restricted to indoor uses till now. On the other hand, in Europe, molded insulators and transformers and so forth have been practically used since the former half of 1960's. Recently, investigation on epoxy resin materials and molded apparatus for outdoor use have ben intensively carried out. Probably, this is because electric power outdoor apparatus such as distribution transformer can be given multi-functions by using outdoor epoxy resin compound This study describes the trend on the development of epoxy mold transformers, and important technologies applied for outdoor use.

  • PDF

도시철도용 몰드변압기 상태감시를 위한 사례조사 연구 (A case study of condition monitoring for mold transformers on urban railway transit)

  • 김도윤;정호성;박영;한석윤;이상빈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • Since urban railway transit is one of the most essential transportation systems, its power facilities must ensure high reliability and safety. Currently, urban railway operating organizations perform TBM (Time Based Maintenance) on power facilities. However, in order to improve management efficiency and system safety, CBM (Condition Based Maintenance) is preferred. Among various power facilities, mold transformers has been chosen as the object of study since it is widely used for the purpose of minimizing volume and weight, and due to safety against fire. In this paper, various transformer failure cases due to electric, thermal, mechanical and environmental factors have been collected and analyzed. In addition, investigation on national and international condition based maintenance cases and the characteristics of sensors widely used for transformer monitoring has been performed to suggest the optimal condition based maintenance technique for urban railway systems.

  • PDF

초음파를 이용한 에폭시 몰드변압기의 열화 진단 (Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves)

  • 이상우;김인식;이동인;이광식;이동희
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.73-81
    • /
    • 1999
  • 본 연구는 초음파 측정법을 사용하여 부분방전에 의한 에폭시 몰드형 전력변압기의 열화상태을 진단하기 위해 에폭시수지의 트리진전에 초음파신호를 분석하였으며, 또한 열화시간에 따른 트리길이, 방전전하량 및 초음파 펄스수의 특성을 조사하였다. 실험 결과, 애폭시수지에 발생된 트리는 수지령이면, 인가전압 16[kV]에 대한 트리 길이 및 트리 폭의 평균성 장률은 각각 0.014 및 0.026[mm/min] 이였으며, 20[kV]의 경우 이들 값은 각각 0.032 및 0.063[mm/min]으로 더욱 증가된 것으로 나타났다. 열화중기 이후 트리가 성장함에 따라 초음파 펄스수 및 부분방전 전하량은 급격히 증가된 것으로 나타났다. 그리고 초음파 펄스수는 방전전하량에 비례하여 증가되었다. 또한 몰드형 전력변압기의 초음파 측정시 기본 데이터를 얻기 위해 초음파 발진 및 수신장치를 사용하여 에폭시수지에 대한 초음파신호의 감쇄, 시간지연 및 지향특성도 조사하였다.

  • PDF