• Title/Summary/Keyword: Mold Analysis

Search Result 1,206, Processing Time 0.024 seconds

Effect of surface treatments on the bond strength of indirect resin composite to resin matrix ceramics

  • Celik, Ersan;Sahin, Sezgi Cinel;Dede, Dogu Omur
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.223-231
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the shear bond strength (SBS) of an indirect resin composite (IRC) to the various resin matrix ceramic (RMC) blocks using different surface treatments. MATERIALS AND METHODS. Ninety-nine cubic RMC specimens consisting of a resin nanoceramic (RNC), a polymer-infiltrated hybrid ceramic (PIHC), and a flexible hybrid ceramic (FHC) were divided randomly into three surface treatment subgroups (n = 11). In the experimental groups, untreated (Cnt), tribochemical silica coating (Tbc), and Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) laser irradiation (Lsr) with 3 W (150 mJ/pulse, 20 Hz for 20 sec.) were used as surface treatments. An indirect composite resin (IRC) was layered with a disc-shape mold ($2{\times}3mm$) onto the treated-ceramic surfaces and the specimens submitted to thermal cycling (6000 cycles, $5-55^{\circ}C$). The SBS test of specimens was performed using a universal testing machine and the specimens were examined with a scanning electron microscope to determine the failure mode. Data were statistically analyzed with two-way analysis of variance (ANOVA) and Tukey HSD test (${\alpha}=.05$). RESULTS. According to the two-way ANOVA, only the surface treatment parameter was statistically significant (P<.05) on the SBS of IRC to RMC. The SBS values of Lsr-applied RMC groups were significantly higher than Cnt groups for each RMC material, (P<.05). Significant differences were also determined between Tbc surface treatment applied and untreated (Cnt) PIHC materials (P=.039). CONCLUSION. For promoting a reliable bond strength during characterization of RMC with IRC, Nd:YAG laser or Tbc surface treatment technique should be used, putting in consideration the microstructure and composition of RMC materials and appropriate parameters for each material.

Analysis of AI-Applied Industry and Development Direction (인공지능 적용 산업과 발전방향에 대한 분석)

  • Moon, Seung Hyeog
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.77-82
    • /
    • 2019
  • AI is applied increasingly to overall industries such as living, medical, financial service, autonomous car, etc. thanks to rapid technology development. AI-leading countries are strengthening their competency to secure competitiveness since AI is positioned as the core technology in $4^{th}$ Industrial Revolution. Although Korea has the competitive IT infra and human resources, it lags behind traditional AI-leaders like United States, Canada, Japan and, even China which devotes all its might to develop intelligent technology-intentive industry. AI is the critical technology influencing on the national industry in the near future according to advancement of intelligent information society so that concentration of capability is required with national interest. Also, joint development with global AI-leading companies as well as development of own technology are crucial to prevent technology subordination. Additionally, regulatory reform and preparation of related law are very urgent.

Quality Evaluations of Induction Motor Rotors during Die Casting Process II (유도전동기 회전자 금형주조 시 품질평가 II)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.347-352
    • /
    • 2019
  • This study focused on improving the cast quality of small-sized induction motor rotors during the die casting process. A new rotor core cast model was proposed based on previous research results and parametric studies. Numerical analyses using 3-dimensional half models were performed to evaluate the filling patterns of aluminum molten metals into a mold and on-site experiment performed to verify the newly proposed cast model. The following were obtained from numerical filling analyses and experimental results. First, molten metals started to fill the lower end ring, then moved on to fill the core slot and upper end ring and finally stopped to fill at the rotor core slot. Second, significant circulation of molten metals was not observed on the lower end ring, resulting in fewer defects at the section of the lower end ring from the experimental results. Third, the new shape of a rotor core cast was effective in producing rotors with sound cast quality, and reducing the end ring cast defect area by approximately 70 %.

A Convergent Investigation on the Air Flow Analysis of a Light Aircraft Propeller (경비행기 프로펠러의 공기 유동해석에 관한 융합 연구)

  • Choi, Kye-Kwang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.12
    • /
    • pp.131-135
    • /
    • 2020
  • In this study, the models with three, five and ten wings of the propeller which made a light aircraft fly were performed by air flow analyses. As for the flow model A with the shape with five wings, Model A can be seen to be the most ideal flow of air. The flow of air through the number of wings, which is not too many or too few, shows the most smooth flowing form. The smaller the number of propeller blades, the smaller the flow of air. Model A is applied under pressure of up to 0.5631 MPa at the front of air flow. Also, models B and C are applied under pressures of 0.5758 MPa and 0.5589 MPa, respectively. Comparing the pressure contours for each model of flux, model B can be shown to have the highest pressure distribution. The result of this study can be used to investigate the air flow without actual testing. It also seems to be helpful in the aesthetic convergent design of light aircraft propeller.

Effects of various zirconia surface treatments for roughness on shear bond strength with resin cement (지르코니아의 거칠기 증가를 위한 다양한 표면처리방법이 레진 시멘트와의 전단결합강도에 미치는 영향)

  • Bae, Gang-Ho;Bae, Ji-Hyeon;Huh, Jung-Bo;Choi, Jae-Won
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.326-333
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effects of various zirconia surface treatment methods on shear bond strength with resin cements. Methods: We prepared 120 cylindrical zirconia specimens (⌀10 mm×10 mm) using computer-aided design/computer-aided manufacturing (CAD/CAM). Each specimen was randomly subjected to one of four surface treatment conditions: (1) no treatment (control), (2) airborne-particle abrasion with 50 ㎛ of Al2O3 (A50), (3) airborne-particle abrasion with 125 ㎛ of Al2O3 (A125), and (4) ZrO2 slurry (ZA). Using a polytetrafluoroethylene mold (⌀6 mm×3 mm), we applied three resin cements (Panavia F 2.0, Super-Bond C&B, and Variolink N) to each specimen. The shear bond strength tests were performed in a universal testing machine. The surfaces of representative specimens of each group were evaluated under scanning electron microscope. We used one-way analysis of variance (ANOVA), two-way ANOVA, and post hoc Tukey honest significant difference test to analyze the data. Results: In the surface treatment method, the A50 group showed the highest bond strength, followed by A125, ZA, and control groups; however, no significant difference was observed between A50 and A125, A125 and ZA, and ZA and control (p>0.05). Among the resin cements, Super-Bond C&B showed the highest shear bond strength, followed by Panavia F 2.0 and Variolink N (p<0.05). Conclusion: Within the limitations of this study, application of airborne-particle abrasion and ZrO2 slurry improved the shear bond strength of resin cement on zirconia.

Comparison between mechanical properties and biocompatibility of experimental 3D printing denture resins according to photoinitiators (광개시제에 따른 실험용 3D 프린팅 의치상 레진의 기계적 성질과 생체적합성 비교)

  • Park, Da Ryeong;Son, Ju lee
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.355-361
    • /
    • 2020
  • Purpose: In this study, we added two kinds of photoinitiators (CQ and TPO) to prepare two kinds of denture base resins (Bis-GMA series and UDMA series) for three-dimensional (3D) printing to compare and analyze their mechanical and biological properties and to find the optimal composition. Methods: Control specimens were made using the mold made of polyvinyl siloxane of the same size. Light curing was performed twice for 20 seconds on both the upper and lower surfaces with LED (light emitting diode) light-curing unit (n=10). Experimental 3D printing dental resins were prepared, to which two photoinitiators were added. Digital light processing type 3D printer (EMBER, Autodesk, CA, USA) was used for 3D printing. The specimen size was 64 mm×10 mm×3.3 mm according to ISO 20795-1. The final specimens were tested for flexural strength and flexural modulus, and MTT test was performed. Furthermore, one-way analysis of variance was performed, and the post-test was analyzed by Duncan's test at α=0.05. Results: The flexural strength of both Bis-GMA+CQ (97.12±6.47 MPa) and UDMA+TPO (97.40±3.75 MPa) was significantly higher (p<0.05) in the experimental group. The flexural modulus in the experimental group of UDMA+TPO (2.56±0.06 GPa) was the highest (p<0.05). MTT test revealed that all the experimental groups showed more than 70% cell activity. Conclusion: The composition of UDMA+TPO showed excellent results in flexural strength, flexural modulus, and biocompatibility.

Brown Felt on Persimmon (Diospyros kaki) Caused by Septobasidium sp. in Korea (Septobasidium sp.에 의한 감 갈색고약병 발생)

  • Ha, Jeong-Seok;Song, In-Kyu;Kim, Seung-Han;Kim, Ji-Won
    • Research in Plant Disease
    • /
    • v.27 no.2
    • /
    • pp.66-69
    • /
    • 2021
  • In 2020, a brown felt was observed on persimmon (Diospyros kaki) in persimmon orchards, Sangju, Korea. The symptom on persimmon was white to grey mycelial mats on some areas of the branches. Each mat progressively expanded until the mats coalesced to occupy larger areas and finally girdled the branches. The disease branches were covered with brown-colored mold, consisting of hyphal mats of the pathogen. Optimum temperature for mycelial growth was 30℃. On the basis of mycological characteristics, pathogenicity test, and molecular analysis with complete internal transcribed spacer rDNA region, the causal fungus was identified as Septobasidium sp. This is the first report of brown felt caused by Septobasidium sp. on persimmon in Korea.

A study on the analysis of heat flow in X-ray tube (X-ray tube 내 열유동 해석에 관한 연구)

  • Yun, Dong-Min;Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.26-31
    • /
    • 2021
  • As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

Evaluation of Scintillation Camera Applications of 3D Printing Phantom (3D 프린팅 팬텀의 섬광카메라 적용 평가)

  • Park, Hoon-Hee;Lee, Ju-young;Kim, Ji-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

A Study on the Analysis of Environmental Hazards when Dismantling Non-Structure of Old Residential Buildings (노후 주거용 건축물 비구조체 해체 시 환경유해인자 분석)

  • Son, Byeung-Hun
    • Journal of Urban Science
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2021
  • The number of old buildings older than 30 years in Korea continues to increase from 29.9% in 2005 to 38.8% in 2020. Considering the growing urban regeneration projects, urban maintenance projects, the suppression of urban expansion, and the lack of idle land in the city, the dismantling of old buildings is expected to increase further in the future. As major accidents at building dismantling sites continue to occur, related agencies are also strengthening safety management of building dismantling works. While physical safety management such as collapse and fall is strengthened, there is a relative lack of interest in the health of workers at dismantling sites due to environmental hazards. Since relevant laws stipulate that construction waste should be separated and discharged, old buildings need to be considered for environmental hazards such as fine dust, floating bacteria, and floating molds when dismantling. In this study, we intend to find important safety management elements in the management of building dismantling sites, measure environmental factors harmful to dismantling workers, and present basic data for the management of dismantling sites in the future. "Safety management" was the highest priority, followed by "dust," "vibration," "noise," "bacteria," and "smell." The perception of the importance of "physical damage prevention" with workers working on dismantling and managers managing the site came out similar, but the perception of "work efficiency" and "health disorder prevention" through environmental hazard management showed different priorities. In the process of dismantling, floating bacteria and floating mold were collected, cultured, and measured the concentration in the indoor air. The measurement was measured by dividing it into pre-dismantling and during dismantling.