• 제목/요약/키워드: Molar region

검색결과 288건 처리시간 0.023초

하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향 (EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS)

  • 김진열;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석 (A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla)

  • 송우석;김명주;임영준;권호범
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.222-228
    • /
    • 2011
  • 연구 목적: 이 연구의 목적은 삼차원 유한요소 분석법을 이용하여 무치악 구개결손 환자에 사용되는 폐쇄장치의 응력 및 변위를 측정하고 이를 총의치 모형과 비교하는 것이다. 연구 재료 및 방법: 무치악 환자의 컴퓨터단층촬영 영상을 기반으로 구개 중앙에 상악절제술 후 발생한 결손부를 가지는 무치악 상악모형과, 무치악 3차원 유한요소 모형을 제작하였다. 각각의 모형에 적합한 총의치와 폐쇄장치를 제작하고 좌측 소구치와 구치 부위에 200 N의 수직하중을 가하였다. 3차원 유한요소 분석법을 이용하여 두 모형에서 보철물과 잔존 상악골조직의 von Mises 응력값과 변위량을 측정하였다. 결과: 두 모형 모두 하중을 가한 쪽의 피질골에서 최대 von Mises 응력 값이 관찰되었다. 총의치 모형의 피질골에서 가장 높은 값은 2.73 MPa 이었으며 폐쇄장치 모형의 피질골에서 가장 높은 값은 2.69 MPa 이었다. 보철물의 조직면에서도 높은 응력값이 관찰되었다. 최대 변위량은 폐쇄장치에서 총의치보다 더 높은 값이 관찰되었다. 결론: 폐쇄장치는 총의치에 비해 교합력 전달 면에서 불리했고, 더 큰 변위량이 관찰되어 상악절제술을 받은 무치악 환자의 보철치료 시 해부학적 지식에 바탕을 둔 정확한 인상채득과 보철치료 원칙의 적용이 고려되어야 한다.

트리메틸올멜라민의 세리신 정착에 있어 정착제와 유연제의 영향 (The Effect of Fixing Agents and Softner on Sericin Fixation of Trimethylolmelamine)

  • 박건용
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.93-98
    • /
    • 2017
  • 트리메틸올멜라민에 의한 세리신 정착 거동을 고찰하기 위해 멜라민과 포름알데하이드를 몰 비 1:3으로 세리신정착액을 조성하여 실크 생사를 정착시켰고, 정련에 의해 세리신 정착 거동을 살펴보았다. 정착 과정에서 세리신의 정착이 일어나는 동시에 열수에 의해 세리신 I의 일부가 제거되었다. 정착 중의 감량과 정련에 의한 연감율은 멜라민과 포름알데하이드의 농도가 증가할수록 크게 감소했다. 0.011몰 멜라민과 0.033몰 포름알데하이드로 정착한 실크 생사는 불충분한 정착과 탄산나트륨에 의한 세리신의 알칼리 가수분해로 인해 많은 정련이 일어났다. 그러나 0.055몰 멜라민과 0.165몰 포름알데하이드로 정착한 실크 생사는 강한 세리신 정착으로 인해 3-8%의 매우 적은 연감율을 보였는데 이는 트리메틸올멜라민에 의해 세리신 I 분자 간에 많은 가교결합이 형성되었기 때문으로 사료된다. 또한 15% owf 유연제의 정착액으로 처리한 경우 정착에 의한 감량과 정련에 의한 연감율이 가장 작게 나타났는데 이는 유연제의 양이온이 세리신 중의 아스파르트산의 음이온과 이온결합을 형성하고 유연제의 소수부와 세리신의 소수성 영역 간에 반데르바알스력이 형성되어 세리신 I의 제거가 다소 억제된 것으로 사료된다.

소아 청소년 환자에서 발생한 269개의 구강 악안면 영역 낭 : 10년간의 후향적 임상 연구 (Analysis of 269 Cases of Jaw Cysts in Children and Adolescents: A Retrospective Study over a Decade)

  • 홍혜린;남옥형;김미선;최성철;이효설
    • 대한소아치과학회지
    • /
    • 제43권3호
    • /
    • pp.237-245
    • /
    • 2016
  • 낭은 액체 또는 반유동성 액체를 함유하는 상피세포층으로 둘러싸인 공동이다. 낭은 모든 연령대에서 진단될 수 있으나, 소아 청소년 환자는 성인들과 다른 병소의 종류와 양상을 보일 수 있으며, 후속 영구치가 발육 중이므로 치료법도 다를 수 있다. 본 연구는 2005년 1월부터 2015년 3월까지 최근 10년간 경희대학교 치과병원을 내원한 19세까지의 소아 청소년환자 중임상적, 방사선학적 및 조직학적으로 낭으로 확진된 253명의 환자들을 분석하였다. 그 결과 낭은 남아 142명(56.1%)에서 다소 많았으며, 치성낭이 209개(82.6%)로 대다수를 차지하였고, 전체적으로 발육성 낭이 염증성 낭보다 많았다. 발육성 낭에서는 함치성낭, 염증성 낭은 치근낭이 많았다. 한편 하악 구치부에서 발생 비율이 높았다. 환자들 중 많은 경우 임상 증상이 없었으며, 낭의 치료 방법으로는 적출술만을 시행하고 원인치 발거를 동시에 진행한 경우가 많았다.

Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가 (EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS)

  • 박지현;황순정;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

교합균형이 자세 중심(重心)에 미치는 영향에 관한 연구 (Effect of occlusal balance on center of gravity in body)

  • 이윤;최대균;이성복
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.57-67
    • /
    • 2003
  • Suppose that dental occlusion is related to body posture. We want to find out that improving occlusal balance may affect vibration and distribution of C.O.P. in which way, by measuring change of posture and center of gravity (center of pressure, C.O.P.) which plays important role in measuring balance sensation. Total 11 students at Kyung Hee dental college students, 4 females and 9 males (age: 23-30) participated in this test, who have normal occlusion (Angle's classification I), no TMJ problems. All of the participants have no tooth loss except 3rd molar, no prosthesis over single tooth restoration, no orthopedic problems which affect balance sensation, and no otorhinolaryngological problems. First, we registrated bite by centric relation, and then fabricated stabilization splint that is increased 3.5mm vertical dimension around premolar region. By F-scan (Tekscan Inc., Boston, Mass), we measured discrepancy of average contact pressure of left and right foot. And we also measured discrepancy of vibration of C.O.P(center of pressure). before setting stabilization splint and after wearing stabilization splint at intervals of 1 week, 2 weeks, 3 weeks after. In normal human beings, improved occlusal balance by stabilization splint leads to decrease of vibration of C.O.P. (P<0.05). One week after wearing stabilization splint, vibration of C.O.P. decreased reliably (P<0.05), two weeks after wearing stabilization splint, vibration of C.O.P. decreased similarly comparing to before wearing and one week after wearing. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. (P>0.05) Difference between average contact pressure of right and left foot also decreased. (P<0.05) We could find decrease after one week of wearing stabilization splint (P<0.05) and two weeks after, the decrease was more reliable than one week after. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. Improvement of occlusal balance leads to decrease of vibration of C.O.P. and decrease of difference between right and left average contact pressure.

상악 임플란트 overdenture에서 anchorage system과 의치상 구개피개가 하중전달에 미치는 영향 (EFFECT OF ANCHORAGE SYSTEMS AND PALATAL COVERAGE OF DENTURE BASE ON LOAD TRANSFER WITH MAXILLARY IMPLANT-SUPPORTING OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS)

  • 제홍지;전영찬;정창모;임장섭;황재석
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.397-411
    • /
    • 2004
  • Purpose: The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-supported overdenture. Material and methods: Maxillary implant -supported overdentures in which 4 implants were placed in the anterior region of edentulous maxilla were fabricated, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional photoelastic stress analysis. Two photoelastic overdenture models were fabricated in each anchorage system to compare with the palatal coverage extent of denture base, as a result we got eight models : Hader bar using clips(type 1), cantilevered Hader bar using clips(type 2), Hader bar using clip and ERA attachments(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4). Result: 1. In all experimental models, the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. In every experimental models with or without palatal coverage of denture base, maximum fringe orders on the distal ipsilateral implant supporting bone in an ascending order is as follows; type 3, type 1, type 4, and type 2. 3. Each implants showed compressive stresses in all experimental models with palatal coverage of denture base, but in the case of those without palatal coverage of denture base, tensile stresses were observed in the distal contralateral implant supporting bone. 4. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant supporting bone on loaded side. 5. The type of anchorage system affected in load transfer more than palatal coverage extent of the denture base. Conclusion: To the results mentioned above, in the case of patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant, and poor bone quality, selecting a resilient type attachment or minimizing the distal cantilevered bar is considered to be an appropriate method to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

국소적 치아 이형성증(Regional odontodysplasia)에 대한 증례 (REGIONAL ODONTODYSPLASIA : CASE REPORT)

  • 이제호;조재현;김기덕;최병재
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.175-179
    • /
    • 2001
  • 국소적 치아 이형성증이란 드물게 나타나는 치아발육장애로서 치아발육이 국소적으로 정지되어 발생되며 이환된 치아의 모든 구성요소가 발육부전이나 석회화 부전을 나타낸다. 국소적 혈액 순환 장애, 체성 돌연변이. 바이러스 침투, 치배 감염, 치아 외상, 이상고열, 방사선조사, 영양, 대사 장애, 유전 등이 원인으로 제시되고 있으나 정확한 원인은 밝혀져 있지 않다. 여성에 많이 발생하고(1.4 : 1) 하악보다는 상악(특히 좌측)에 많이 나타나는 것으로 보고되고 있다. 이환 받은 치아는 크기가 작고, 저형성을 보이며, 노란색 또는 노란 갈색을 띄고, 소와와 구(pitting & grooving)를 보이기도 한다. 방사선적으로 "ghost like appearance" "fuzzy appearance"등을 보이고 치수강 내에 치수석회화물이나 상아질석이 보이기도 한다. 본 증례의 2세 남자 환아는 하악 우측 치아의 맹출 지연을 주소로 연세대학교 병원 소아치과에 내원하였다. 하악 우측 유중 절치의 부분 맹출과 유측절치, 유견치, 제 1유구치가 미맹출을 보였고, 방사선 검사소견에서 해당부위의 치아는 "Ghost like appearance"와 짧은 치근, 개방된 치근첨의 소견이 관찰되었다. 임상, 방사선 검사결과 국소적 치아 이형성증으로 판단되어 이에 대한 보고를 하는 바이다.

  • PDF

구내 촬영용 방사선 장치의 촬영조건에 따른 선량변화 분석 (Analysis of Condition Changing on Dose Variation using Intraoral Radiation Devices)

  • 김영재;이용탁;송현철
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.137-142
    • /
    • 2012
  • 본 연구는 구강 내 방사선 촬영 시 동일조건 하에서 촬영장비의 기종을 다르게 한 경우와 동일 기종에서 노출조건을 일정하게 하였을 경우 획득되는 방사선의 선량변화를 알아보고자 하였다. 장비의 기종에 따른 변화를 알아보기 위해 3대의 각기 다른 촬영 장치를 이용하여 상악 전치부, 소구치부, 대구치부의 3가지의 촬영조건을 이용하여 선량을 측정하였고 장치의 재현성 검사를 위해서 각 장치에 동일한 조건으로 3회 조사하여 선량변화를 알아보았다. 선량의 측정은 반도체 측정기를 사용하였으며, 필름의 농도값을 획득하여 진단에 유효적인 범위에 만족하는지 분석해 보았다. 같은 촬영기를 사용하여 실험한 결과 각 부위별로 선량의 차이는 최대값과 최소값이 적게는 3배 많게는 10배의 선량 차이를 보였다. 흑화도의 범위 또한 적절한 범위인 0.25~2.0를 초과한 2.10~2.95의 허용범위를 보였다. 동일한 촬영기로 특정 부위를 같은 조건에서 촬영하더라도 측정된 선량값은 큰 차이를 보였으며 필름의 농도 분석의 결과 적합한 농도 분포를 보이지 않았던 것으로 나타났다. 이는 환자의 재촬영을 발생시킬 수 있으며 진단시 오류를 일으킬 수 있어 환자의 피폭에 직 간접적인 피해를 일으킬 수 있다. 따라서 치과 방사선 촬영장치 또한 정기점검이 필요할 것으로 생각되며 표준화된 촬영조건과 현상조건이 제공되어야 한다고 사료된다.

형질전환 벼에서 brazzein 감미단백질의 안정적인 발현 (Stable expression of brazzein protein, a new type of alternative sweetener in transgenic rice)

  • 이예림;샤히나;이인혜;정여진;박소영;조용구;강권규;정유진
    • Journal of Plant Biotechnology
    • /
    • 제45권1호
    • /
    • pp.63-70
    • /
    • 2018
  • Brazzein은 열대식물인 P. brazzeana Baillon의 과실에서 분리된 가장 작은 감미단백질로 토착민들의 단맛원료로 사용되어 왔다. Brazzein은 sucrose보다 분자량 기준으로 500 ~ 2000배, 몰 기준으로 9500배 당도가 높아 감미료로써 매우 높은 평가를 받고 있다. 그러나 이 감미단백질은 재배가 어렵고 생산 비용이 높아서 brazzein 단백질의 이용 가능성을 높이기 위한 대체 생산 시스템으로 형질전환 식물체 육성 하고자 하였다. 본 연구에서는 brazzein 관련 유전자를 벼에 도입하기 위하여 식물형질전환용 Ti-plasmid에 $2{\times}CaMV\;35S$ 프로모터에 의해 지배되어 발현하도록 하고, 선발 마커로 bar 유전자가 삽입된 식물발현 벡터를 구축하여 A. tumefaciens EHA105에 형질전환시켜 17개의 재분화 식물체를 육성하였다. 17개 재분화 식물체는 PCR 및 RT-PCR 분석을 통하여 유전자 도입 및 발현을 확인하였으며, TaqMan PCR을 통해 single copy로 도입된 T0 세대 9개체를 선발하였다. 또한 FST 분석을 통하여 도입 유전자가 intergenic으로 삽입된 개체 5개를 선발하였다. 이들 5개체를 이용하여 western blot 분석에 의해 단백질 발현량을 분석한 결과 선발된 모든 개체에서 발현 밴드를 확인하였다. 그 중 brazzein 단백질의 발현량이 높은 개체를 TG11으로 계통화하여 후대 종자를 육성하였다. TG11 계통은 천연 감미료 brazzein을 생산하는 새로운 벼 품종을 개발하기 위한 육종 소재로 활용 가능하다고 시사된다.