• Title/Summary/Keyword: Moisture resistance

Search Result 470, Processing Time 0.029 seconds

Evaluation of Field Application and Laboratory Performance of Warm-Mix Asphalt According to the Dosage Rate of Additive (중온화 첨가제 첨가비율에 따른 현장 적용성 평가 및 실내 역학적 거동 특성 연구)

  • Yang, Sunglin;Baek, Cheolmin;Hwang, Sungdo;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.117-125
    • /
    • 2013
  • PURPOSES : The purpose of this study is to evaluate of field application and laboratory performance of warm-mix asphalt (WMA) according to the dosage rate of organic-based WMA additive. METHODS: Three asphalt mixtures, i.e., hot mix asphalt (HMA), WMA with the dosage rate of 1.5%, WMA with the dosage rate of 1.0%, were sampled from the asphalt plant when the field trial project were constructed. With these mixtures, the laboratory testings were performed to evaluate the linear viscoelastic characteristics and the resistance to moisture, rutting and fatigue damage. RESULTS : From the laboratory test results, it was found that the WMA with the reduced dosage rate of additive would be comparable to HMA and WMA with the original dosage rate in terms of the dynamic modulus, tensile strength ratio, rutting resistance. However, the fatigue reisistance of WMA with the reduced dosage rate was slightly worse but it should be noted that the fatigue performance is necessarily predicted by combining the material properties and pavement structure. CONCLUSIONS: Through the field construction and laboratory testings, the dosage rate of organic-based WMA additive could be reduced from 1.5% to 1.0% without the significant decrease of compactability and laboratory performance. The long-term performance of the constructed pavement will be periodically monitored to support the findings from this study.

An Experimental Study on Durability of Concrete Covered with Antibiotics (항균제를 도포한 콘크리트의 내구특성에 관한 실험적 연구)

  • Lee Eui-Bae;Lee Dong-Heck;Moon Hyung-Jae;Kim Jae-Hwan;Kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.97-100
    • /
    • 2005
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent the growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, durability such as resistance to carbonation, salt damage and chemical attack of concrete covered with inorganic and complex antibiotics were investigated. As a result of this study, it was proved that the antimicrobial performance of antibiotics was available. Also resistance to carbonation, salt damage and chemical attack of concrete covered with inorganic antibiotics was little improved but, in case of complex antibiotics, was remarkably improved. Moisture content of concrete, as a application condition of antibiotics in whole case, have little effect on performance but covering times of antibiotics have effect on performance only in case of complex antibiotics.

  • PDF

Influence of the Application of Plant Growth-Regulating Hormone upon the Resistance to Grain Dropping of Indica-Japonica Species Rice (식물성장조절호르몬의 시용이 Indica-Japonica계 벼의 탈입저항에 미치는 영향)

  • 차균도;조성찬
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.66-71
    • /
    • 1984
  • In order to find out the effect of a plant growth regulating hormone, commonly called as 2, 4, 5-TP, for checking the resisting energy against falling of grain of Indica-Japonica species rice, an experiment was conducted with five levels of consistency (5,10, 15, 20, 25 ppm) and with four levels of spray timing (8, 17, 27, 34 DAH). Ten applications were made for measuring the resisting energy of rice heads sampled from every lot of treatments. Followings are the results; 1.The rice heads applied with 2, 4, 5-TP showed remarkably higher resisting energy against falling of grain comparing with those from the control plot. 2.The highest average value of the resisting energy was found as 83, 326 erg per grain on the plots of 8 DAH spray. 3.The general tendency was found that the more the timing of spraying was early, the more the consistency was lean. 4.A regression equation for expressing the peak resistance versus the timing was derived by means of least squares as follow; C=0. 00042D$^3$-0. 012D$^2$+0. 267D+8. 394 5.No significant differences were found among the values of weight per 1, 000 grains neither among moisture content.

  • PDF

A Study on the Insulation Properties for Stator Form-wound Winding by Thermal Degradation Test (가속 열열화 시험에 의한 고정자 형권 코일의 절연특성에 관한 연구)

  • 채승훈;김상걸;오현석;신철기;왕종배;김기준;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.115-118
    • /
    • 2000
  • In case of developing new motor, many examinations was tested to decide a motor efficiency and reliability. To give reliability judgment, traction motor winding insulation was tested by electrical method after appling electrical, heat, mechanical, environmental stress. In this study, stator form-wound winding of traction motor in urban transit E.M.U was tested by accelerative thermal degradation test. Stator form-wound winding was tested on the accelerative degradation composed of heat, vibration, moisture, overvoltage and researched insulation resistance, dielectric loss, partial discharge for insulation degradation properties, evaluated withstand voltage. Degradation temperature was $230[^\circ{C}]$, $250[^\circ{C}]$, $270[^\circ{C}]$, for stator form-wound winding respectively. On the test results of accelerative thermal degradation, insulation properties were relied all temperature until 10 times and expected life was evaluated by the rule of reducing $10[^\circ{C}]$ life into halves. Expected life was 31.8 years. It is guaranteed insulation reliability because of exceeding 25 years life times as considering.

  • PDF

The performance analysis of photovoltaic module accounting for solar cell degradation and series resistance (태양전지 셀의 열화와 직렬저항의 변화에 따른 태양전지 모듈의 특성 해석)

  • Park, Chi-Hong;Kang, Gi-Hwan;Waithiru, L.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.28-29
    • /
    • 2006
  • When photovoltaic module is used for a long time, its performance decreases due to several reasons. In this paper, we focus on the possibilities mainly contributing to the degraded efficiency of the polycrystalline silicon photovoltaic modules. The analysis is based on the modules that have been used for 15 years. These are two main reasons that cause the efficiency degradation, the corrosion and thermal decomposition. The former phenomenon of electrode is mainly due to the moisture from damaged back sheet in some module. However the other reason of the degraded efficiency comes from the thermal decomposition, which can not be observed from the outside but only by experiment. In this study, the comparison between the efficiency of normal modules and degradation modules is presented. Module having degraded cell was seen to cause increase of series resistance by about 80%, in comparison to normal samples efficiency which reduce by about 20%. This study shows that the effects of series resistances on module performance are critical. These effects must be understood and taken into consideration when analyzing performance degradation.

  • PDF

Strain Analysis by Measured Displacement Data (측정 변위를 이용한 변형률 해석)

  • Kim, Tae Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.147-155
    • /
    • 2002
  • To find the safety and serviceability of bridges, it must consider the behaviour of structural member and evaluation of the exact resistance of the member subjected to external loads. To evaluate the behaviour and the resistance of the structural member, it must measure the strains and displacements of the structures. Usually we use the strain gauge to measure the strains. When, the bridge is long span and high pier, the setting of strain gauge is very difficult and not economic. It is not recommendable for the use of strain gauge, when the structural member has many cracks and moisture. Thus, to make up for this demerits, the algorithm of strain analysis by measured displacements data is proposed.

Fabrication of Organic Electrolytes for Electric Double Layer Capacitor with Activated Carbon Cloth Electrode (활성탄소계 섬유포 전극을 이용한 전기이중층 커패시터용 유기 전해액의 제조)

  • 강안수
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.2
    • /
    • pp.95-108
    • /
    • 2000
  • Electrochemical charateristics of activated carbon fiber cloth(ACFC) electrode were studied with propylene carbonate(PC), ${\gamma}$-butyrolactone(GBL) and N,N-dimethyl-formamide(DMF) as a solvent and tetraethylammoniumtetrafluoroborate(TEABF$_4$), tetraethylammoniumhexafluorophosphate(TEABF$_{6}$), tetrabutylammoniumtetrafluoroborate(TBABF$_4$) and tetrabutylammonium hexafluorophosphate(TBAPF$_6$) as an electrolytes(active material). The concentrations of electrolytes were in the range of 0.2~1.2 N, the volume ratios of PC and DMF as a mixed solvent system, were 90:10, 80:20, 70:30, 60:40, 50:50, and 40:60 vol%. Electrochemical characteristics such as electric conductivity, internal resistance, and electric capacitance of fabricated unit cells were measured after the moisture of activated material was removed with molecular sieve. Electrochemical characteristics were better in mixed solvents system than in mono solvent system. The mono solvent system of 1.0 N electrolyte of GBL/TEABF$_4$ with activated carbon cloth electrodes showed better result but the mixed solvent system with PC and DMF/TEABF$_4$(50:50 vol%) and the concentration of 1.0 N electrolyte showed the best characteristics. Internal resistance was 3.47 $\Omega$ and specific capacitance was 19.1 F/g respectively.y.

  • PDF

Research Trend of OCA (Optically Clear additive) for Display Panel by Analysis of Patent and Papers Publication (특허 및 논문 분석을 통한 디스플레이용 접착제의 기술경쟁력 분석)

  • Woo, Chang Hwa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.75-84
    • /
    • 2018
  • According to IHS, the overall display market is expected to grow at an average annual rate of 6% from $ 104 billion in 2016, to $ 138 billion in 2021. Among them, the OLED display panel will grow from $ 15 billion to $ 41 billion over the same period, forecasting a high annual growth rate of 22%. However, the refraction index, light leakage, bubble generation, adhesion deterioration, peeling phenomenon, moisture resistance, light transmittance, low turbidity. OCA (optically clear adhesive), which solves problems such as improving the resistance of the conductive film, is largely dependent on imported products. In addition, in 2016, the world market is worth KRW4.3 trillion, and the adhesive market has a large market effect. In this study, we tried to analyze the technical competitiveness of patent and thesis by classifying OCA (optically clear adhesive, optical adhesive) for display panel by curing method. As a result of the study, the amount of patents and papers in Korea was found to be superior to other competitors, but the quality level was low. In particular, it was found that the achievements of the papers in the hot melt field are lacking and the government should expand its support.

Corrosion of Steel Rebar in Concrete: A Review

  • Akib Jabed;Md Mahamud Hasan Tusher;Md. Shahidul Islam Shuvo;Alisan Imam
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.273-286
    • /
    • 2023
  • Rebar is embedded in concrete to create reinforced concrete (RC). Rebar carries most of the tensile stress and gives compressively loaded concrete fracture resistance. However, embedded steel corrosion is a significant cause of concern for RC composite structures worldwide. It is one of the biggest threats to concrete structures' longevity. Due to environmental factors, concrete decays and reinforced concrete buildings fail. The type and surface arrangement of the rebar, the cement used in the mortar, the dosing frequency of the concrete, its penetrability, gaps and cracks, humidity, and, most importantly, pollutants and aggressive species all affect rebar corrosion. Either carbonation or chlorides typically cause steel corrosion in concrete. Carbonation occurs when carbon dioxide in the atmosphere combines with calcium within the concrete. This indicates that the pH of the medium is falling, and the steel rebar is corroding. When chlorides pass through concrete to steel, corrosion rates skyrocket. Consideration must be given to concrete moisture. Owing to its excellent resistance, dry concrete has a low steel corrosion rate, whereas extremely wet concrete has a low rate owing to delayed O2 transfer to steel surfaces. This paper examines rebar corrosion causes and mechanisms and describes corrosion evaluation and mitigation methods.

Flame Retardant Performance of Functional Oil Stains According to the Mixing Ratio of Inorganic Flame Retardants and Phosphorus Flame Retardants (무기계 방염제와 인계 방염제 혼합비율에 따른 기능성 오일스테인의 방염성능)

  • Lee, Ju-Won;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.29-30
    • /
    • 2023
  • Wood is a construction material that has the advantages of carbon dioxide storage ability, noise reflection, and eco-friendliness. In order to use wood for a long time, you must use wood-specific paint, which is called oil stain. Oil stain improves water resistance and moisture resistance, but has the disadvantage of being weak against fire. This is because the oil contained in the oil stain causes a chemical reaction, and this chemical reaction causes the oil stain to spontaneously ignite, igniting nearby combustible materials and causing frequent fires. To improve this, in this study, different flame retardants were mixed and added to oil stain to produce functional oil stain. In addition, we would like to apply it to wood to check glow time and carbonization area. As a result of the experiment, it shows the best performance when mixed at 30(15 + 15)(%) and added to oil stain. The remaining burn time is satisfied from 10% for all samples, and the carbonized area is satisfied when it is 30%.

  • PDF