• Title/Summary/Keyword: Moisture condensation

Search Result 56, Processing Time 0.02 seconds

Adsorption Isotherms Models and Moisture Adsorption Characteristics of Tobacco (담배의 수분 흡착 특성과 흡착 등온식의 모델에 관한 연구)

  • O, In-Hyeok;Kim, Gi-Hwan;Jeong, Gyeong-Rak
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.18 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this study, to obtain the basic data for the optimum moisture control system, moisture adsorption characteristics, adsorption isotherms models for water and surface physical characteristics of burley and flue-cured tobacco were investigated. By the hypothesis' the phenomenon of moisture adsorption of tobacco is the same as the first order reaction, the wetting constant (k) and equilibrium moisture content were obtained. And activation energy, frequency factors were also calculated by applying its data to Arrhenius equation. The Kamei's empirical formula of moisture adsorption isotherms showed the best agreement with the experimental data and its correlation coefficient (r) was 0.997. It can be seen that specific surface area of burley is 157 m2/g, that of flue-cured is 152 m2/g, -△H1 of adsorbed monolayer is 45,972 J/mol, 45,486 J/mol, respectively, and the condensation heat (40,595 J/mol) being caught in adsorbed multilayer is less than that of monolayer.

  • PDF

Low Temperature Vulcanization of Chlorosulfonated Polyethylene (Chlorosulfonated Polyethylene의 저온가황반응(低溫加黃反應))

  • Park, Keun-Sik;Park, Sung-Ha;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.27 no.4
    • /
    • pp.255-261
    • /
    • 1992
  • Chlorosulfonated polyethylene(CSM) was moisture-cure after treating them with silane coupling agents such as ${\gamma}-mercapto$ propyl trimethoxy silane, ${\gamma}-glycidoxy$ propyl triethoxy silane and methyl triethoxy silane, 3-(trimethoxy silyl) propyl methacrylate and 3-thiocyanopropyl triethoxy silane. The cure reaction is composed two steps. The first is the reaction between chlorosulfonyl groups of CSM and silane coupling agents. The second is the formation of cross-links which are siloxane linkage. The linkage is formed by the condensation of silanol groups which are produced by the hydrolysis of alkoxysilyl groups. CSM was mixed with MPS etc., and dilaurate dilaurate as catalyst on two open mill and the compounds were lured in hot water at $70^{\circ}C$ Physical properties of moisture-cured CSM was measured. CSM was effectively moisture-cured and r-mercapto propyl trimethoxy silane and r-glycidoxy propyl trimethoxy silane were capable of the vulcanizing agents.

  • PDF

Study on Moisture Variation in Light Frame Wall with Different Wall Assemblies (I) - Evaluation of Improvement with Laboratory Test - (벽체구성에 따른 목조벽체 내 수분변화에 대한 연구(I) - 실내 실험을 통한 개선 가능성 평가 -)

  • Kim, Se-Jong;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.320-329
    • /
    • 2009
  • The purpose of this study was reducing the moisture accumulation in a wall, which can threaten the structural safety of light-frame wall and make residential environment poor. For the purpose, the laboratory test was carried out with different wall assemblies. Vapor retarder and air gap for ventilation were added to the typical wall. The improved performance of the proposed walls was examined through the test with distinct difference of temperature and relative humidity between outdoor and indoor air conditions. Increased dampproofing performance of additional vapor retarder was effective on reduction of moisture transmission from inside the house into the wall. However, unexpected high relative humidity was shown in the wall with two additional vapor retarder because of excessive dampproofing performance or inadequate location of vapor retarder. And, the open air gap induced the moisture transfer from inside the wall into outdoor air by ventilation. If the alternative to the induction of moisture transmission from inside the house into the wall with open air gap can be found, moisture reduction effect of that will be increased obviously.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

Moisture Movement in Softwood and its Activation Energy (침엽수재(針葉樹材) 내부수분이동(內部水分移動)과 확산활성화(擴散活性化)에너지)

  • Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.27-33
    • /
    • 1991
  • Three kinds of specimens(radiata pine sapwood, radiata pine heartwood and whemlock heartwood) were dried at four temperature levels (30, 40, 50 and $60^{\circ}C$) in an emvironmental chamber. Unsteady-state diffusion coefficients were calculated from obtained drying fates by using infinite slab equation for first half of sorption and interval diffusion equation for second half of sorption. Activation energies for moisture diffusion in wood were calculated from the diffusion coefficients obtained at four temperatures. In most cases diffusion coefficients for radial movement were higher than those for tangential movement. Activation energy differences between sapwood and heartwood weren't significant for radial movement, but were significant for tangential movement. Most activation energies calculated from drying rates were lower than heat of water condensation(about 11,000cal/mole). Specially the avenge activation energy for sapwood tangential movement was only 5,000cal/mole.

  • PDF

Designing an Outdoor Linear LED Luminaire with Gore-Tex Filters

  • Woo-young Kim;Seong-Kweon Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.93-102
    • /
    • 2024
  • We introduce a novel outdoor linear LED luminaire enhanced with Gore-Tex filters, designed to overcome the challenges of moisture and thermal management in harsh environments. This luminaire integrates expanded polytetrafluoroethylene (ePTFE)-commercially known as Gore-Tex-achieving superior waterproofing and dustproof qualities while maintaining breathability to prevent internal condensation. The design process, from conceptualization through prototyping and testing, is detailed, highlighting the luminaire's improved durability and stability under varying conditions. Experimental results demonstrate that our design significantly extends the operational lifespan and reliability of outdoor LED lighting systems by mitigating thermal and moisture-related degradation. This study not only advances ePTFE's application in lighting technologies but also offers a scalable model for enhancing the performance of LED luminaires in outdoor settings.

Coupled evaluation of the free vibration characteristics of magneto-electro-elastic skew plates in hygrothermal environment

  • Mahesh, Vinyas;Kattimani, Subhaschandra;Harursampath, Dineshkumar;Trung, Nguyen-Thoi
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.267-292
    • /
    • 2019
  • The present article addresses the coupled free vibration problem of skew magneto-electro-elastic plates (SMEE) considering the temperature-moisture dependent material properties. The plate kinematics follows Reddy's higher order shear deformation theory. With the aid of finite element methods, the governing equations of motion are derived considering the Hamilton's principle and solved by adopting condensation technique. The influence of different temperature and moisture dependent empirical constants on the frequency response of SMEE plate has been assessed. In addition, the natural frequencies corresponding to various fields are evaluated and the effect of empirical constants on these coupled frequencies is determined. A detailed parametric study has been carried out to assess the individual effects of temperature and moisture dependent empirical constants along with their combined effect, aspect ratio, length-to-width ratio, stacking sequence and boundary conditions. The results reveal that the external environment as well as the geometrical skewness has a significant influence on the stiffness of the SMEE plates.

Characteristics of Fog and Mist Observed in the Rural Area of Chongju and Chongwon (청주-청원 지역에서 관측한 안개와 박무의 특성 연구)

  • 윤마병;정용승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 1996
  • Daily measutements of visibility on 09 LST have been made at a rural site in Chong-won, Chong-book since 1991 to find out a possible influence of emissions of anthropogenic pollutants and water vapout in urban and rural environments. Daily visibility data collected over four-year period were compared with the available visibility and air quality data obtainde from other stations. Detailed examinations of our data showed that the frequency of fog occurrence (visibility .leq. 1 km) at a rural site (KNUE) was at least three times higher (77 days per year) than the frequency of fog both in Chong-ju city (19 days) and at the Air Force Base(AFB) in the rural area. We interpret that the higher frequency of fog at KNUE was due to abundant water vapour in the Mieho River (upstream of the Keum River) area. In Chong-ju city, fog usually continued for a relatively long duration, while it dissipated simewhat faster in the rural environment due to higher solar radiation in the countryside area. The number of misty (.leg. 6 km) days (including foggy days) at KNUE were 235 days as compared with 135 days at the AFB and 67 days in Chong-ju city. In turn the number of days with low visibility (less than 6 km) at KNUE was about 64% per year. Since the moisture alone in a calm morning does not produce a visibility impairment, there must had abundant condensation nuclei including anthropogenic air pollutants. Air pollution was examined, for instance, average values of TSP for November and December 1993 were 115 and 116.mu.g/m$^{3}$, respectively. We conclude that the above mentioned environmental conditions with moisture are favourable for the formation of fog and mist in the rural sampling site at KNUE. Additionally, we found at least 10 days of acid fog at KNUE in September 1994 alone. Measured pH values in the acid for water were in the range of 4.36 .sim. 5.01 with the mean value of 4.51 Our observations suggested that strikingly acid fog do occur occasionally even in the rural environment.

  • PDF

Effects of Relative Humidity and Fiber Properties on the Moisture Permeability of Multilayer Fabric Systems (환경 및 섬유 특성이 멀티레이어 직물시스템의 투습성에 미치는 영향)

  • Suhyun Lee;Sohyun Park
    • Fashion & Textile Research Journal
    • /
    • v.25 no.1
    • /
    • pp.119-126
    • /
    • 2023
  • This study aimed to determine the effects of relative humidity and fiber properties on the moisture permeability of multilayer systems by measuring water vapor transmission in the overlapping condition of various fabrics. The results confirmed that the property of the fabric in contact with the humid environment affects the moisture permeability. If the layer facing the humid environment is hydrophobic and the layer facing the dry environment is superhydrophobic, water vapor transmission increases by up to 17.8% compared to the opposite conditions. Comparing the correction values of the water vapor transmission reflecting the thickness of the specimen under the multilayer condition showed that permeability was higher when the hydrophilic or hydrophobic layer was facing the humid environment. The opposite was true from the "push-pull" effect of absorption mechanism. In the case of moisture permeability, the more hydrophilic the surface facing the humid environment, the more permeable that water vapor diffuses and passes through. It was concluded that the "pull-push" effect, in which water vapor diffuses widely through the hydrophilic facing a humid environment and then passes through the hydrophobic layer, contributes to the improvement of permeability. Permeability differed according to the multilayer overlapping condition. When the relative humidity was high, the "pull-push" effect was insignificant. This is caused by water droplets absorption after the partial migration of water due to condensation. These results suggest that the overlapping conditions and properties of fabrics should vary depending on heavy sweating or not.