• Title/Summary/Keyword: Module cell

Search Result 737, Processing Time 0.023 seconds

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

Effect of nanosilica and TEOS in hydrophilic coating solution on the surface characteristics of solar cell glass panel (나노실리카와 TEOS가 함유된 친수성 코팅액의 태양광 유리팬널에 미치는 표면 특성 연구)

  • Lee, Soo;Kim, Seung Hye;Hwang, Heon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.152-162
    • /
    • 2017
  • A hydrophilic coating solution was prepared by adding a silane coupling agent and a nano-inorganic oxide in aqueous surfactant solution to increase the efficiency of photovoltaic power generation due to the introduction of antifogging and antifouling properties on the glass surface of the solar cell module. Addition of $Ludox^{(R)}$, a nano-inorganic oxide, to 1% hydrophilic coating solution showed improved hydrophilicity and excellent antifogging effect regardless of $Ludox^{(R)}$ concentration. However, the antifouling effect on the glass surface was showed only when Ludox was added more than 10%. In the case of addition of 0.7% of hydrolyzed TEOS at pH 4, the antifogging effect was maintained as a result of the steam test as well as the antifouling effect even after the coated glass surface was rubbed 100 times with a wet Kimwipe. In addition, from the surface roughness ($R_q$) calculated using AFM data, the higher surface roughness with irregular surface shape was obtained with the higher concentration of TEOS. The addition of 0.7% of TEOS showed relatively high surface roughness and well organized surface condition which can help to improve transmittance of light. In conclusion, $Ludox^{(R)}$ is not required only for the antifogging property. However, at least 10% of Ludox should be added to show antifouling effect and 0.7% of TEOS should be added for good durability.

Screening for Patients with Non-small Cell Lung Cancer Who Could Survive Long Term Chemotherapy

  • Wu, Xue-Yan;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.647-652
    • /
    • 2015
  • Background: Lung cancer was one of the most common cancers in both men and women all over the world. In this study, we aimed to clarify who could survive after long term chemotherapy in patients with advanced non-small cell lung cancer (NSCLC). Methods: We enrolled 186 patients with stage IV NSCLC after long term chemotherapy from Jun 2006 to Nov 2014 diagnosed in Jiangsu Cancer Hospital. Multiple variables like age, gender, smoking, histology of adenocarcinoma and squamous-cell cancer, number of metastatic sites, metastatic sites (e.g. lung, brain, bone, liver and pleura), hemoglobin, lymphocyte rate (LYR), Change of LYR during multiple therapies, hypertension, diabetes, chronic bronchitis, treatments (e.g.radiotherapy and targeted therapy) were selected. For consideration of factors influencing survival and response for patients with advanced NSCLC, logistic regression analysis and Cox regression analysis were used in an attempt to develop a screening module for patients with elevated survival after long term chemotherapy become possible. Results: Of the total of 186 patients enrolled, 69 survived less than 1 year (short-term group), 45 one to two years, and 72 longer than 3 years (long-term group). For logistic regression analysis, the short-term group was taken as control group and the long-term group as the case group. We found that age, histology of adenocarcinoma, metastatic site (e.g. lung and liver), treatments (e.g. targeted therapy and radiotherapy), LYR, a decreasing tendency of LYR and chronic bronchitis were individually associated with overall survival by Cox regression analysis. A multivariable Cox regression model showed that metastatic site (e.g. lung and liver), histology of adenocarcinoma, treatments (e.g. targeted therapy and radiotherapy) and chronic bronchitis were associated with overall survival. Thus metastatic site (e.g. lung and liver) and chronic bronchitis may be important risk factors for patients with advanced NSCLC. Gender, metastatic site (e.g. lung and liver), LYR and the decreasing tendency of LYR were significantly associated with long-term survival in the individual-variable logistic regression model (P<0.05). On multivariate logistic regression analysis, gender, metastatic site (e.g. lung and liver) and the decreasing tendency of LYR associated with long-term survival. Conclusions: In conclusion, female patients with stage IV adenocarcinoma of NSCLC who had decreasing tendency of LYR during the course therapy and had accepted multiple therapies e.g. more than third-line chemotherapy, radiotherapy and/or targeted therapy might be expected to live longer.

Traditional Korean Medicine for Skin Toxic Side Effects from Afatinib in a Non-Small Cell Lung Cancer Patient: A Case Report (Afatinib 복약 후 발생한 비소세포성 폐암환자의 피부독성 부작용에 대한 한방치료 1례)

  • Shim, So-hyun;Seo, Hee-jeong;Choi, Jin-yong;Bae, Go-eun;Seo, Hyung-bum;Kim, So-yeon;Han, Chang-woo;Park, Seong-ha;Yun, Young-ju;Lee, In;Kwon, Jung-nam;Hong, Jin-woo;Choi, Jun-yong
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.5
    • /
    • pp.973-983
    • /
    • 2018
  • Objectives: We report a case of traditional Korean medicine (TKM) treatment for skin side effects after taking afatinib (Giotrif$^{(R)}$). Methods: A 62-year-old female who was diagnosed with non-small cell lung cancer stage 4 (T4N2M1b) and was on treatment with afatinib (29.56 mg/day for 4 months) complained of skin toxicity as a side effect. For 16 admission days, the patient was treated with acupuncture, moxibustion, and herbal medicine (oral decoction and external ointment). Results: Improvement of skin toxicity was measured by a numeric rating scale. In addition, Quality of life (QOL) was measured using EORTC Quality of Life Questionnaire, Core 30 (EORTC QLQ-C30) and EORTC Quality of Life Questionnaire, 13-item lung cancer-specific module (EORTC QLQ-LC13) Developed by the European Organization for Research and Treatment of Cancer (EORTC). Tumor size and carcinoembryonic antigen (CEA) were also examined during follow up. Conclusions: After a combined TKM treatment, skin toxicity symptoms and quality of life scales were significantly improved with no side effects. The tumor size was not changed on computed tomography during follow-up period. CEA levels were decreased.

Numerical study on the thermal performance characteristics of the stack system for FCEV (연료전지 자동차용 스택 시스템의 열적 성능 특성에 관한 수치적 연구)

  • Lee, Ho-Seong;Lee, Moo-Yeon;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3708-3713
    • /
    • 2015
  • The objective of this study is to numerically investigate the heat transfer rate for evaluating the thermal performances of the stack thermal system using the commercial software. In order to perform this, the cooling performances of the stack system for fuel cell electric vehicle were tested under both driving road conditions including the general driving road and uphill driving road and operating conditions with and without of the air conditioning system. The heat transfer rate of the stack radiator for the stack system was increased with the increase of the inlet air flow velocity. The heat transfer rate of the stack radiator increased by 105.3% at the coolant flow rate of 20 l/min and 221.3% at the coolant flow rate of 120 l/min with the increase of the air flow velocity from 2 m/s to 10 m/s. $9.45^{\circ}C$ of inlet coolant temperature of the stack radiator at the severe driving condition of the slope of 8% and velocity of 50 km/h showed higher 85.3% than $5.1^{\circ}C$ of inlet coolant temperature at the general driving condition of the slope of 0% and velocity of 120 km/h. In addition, as the fuel cell electric vehicle with the air conditioning system operation was driving under severe uphill driving condition, the radiator coolant temperature for a stable stack operation could be exceeded over $70^{\circ}C$.

Current Status and Utilization Technology of End-of-Life Photovoltaic Modules (태양광 폐 모듈의 처리현황 및 실용화 기술)

  • Cho, Jai Young;Park, Areum;Yun, Hyun Mok;Jun, Yun-Su;Kim, Joon Soo
    • Resources Recycling
    • /
    • v.29 no.4
    • /
    • pp.15-30
    • /
    • 2020
  • Recently, it is increasing a amount of installed solar-cell rapidly, and end-of-life photovoltaic(ELP) modules are generated in according to the reduction of cell efficiency largely. Recycling of ELP modules are begun at an advanced nation already, but there are bring about environmental contamination and resource recovery problems owing to not treated ELP modules because of economic cost completely. First of all, there were researched basic study for treatment conditions of used solar cell inspection, dismantling of aluminum frame, crushing / grinding & separation of tempered glass, removal of back sheet & EVA film, leaching & precipitation recovery of valuable metals and treatment of waste water. Therefore, we establish optimum conditions through carried out of designed apparatus, installation of equipment, test operation & trouble shooting in scale of 1ton/day pilot plant test. Following to economic review, it does have the economic efficiency until to the case of tempered glass recovery, but does not have the economic value in case of total processes until to recover the valuable metals. However, there are guaranteed economic value if we are gained a large amount of the expenses through EPR supported system. It was confirmed the commercialized possibility of ELP modules recycling if there were established on the collecting ELP modules, reusing criteria, economical technology, enactment of directives and enforcement of EPR supported system efficiently.

Traditional Korean Medicine for Non-Small Cell Lung Cancer Patient Undergoing Pembrolizumab Immunotherapy: A Case Report (Pembrolizumab 면역치료를 시행 중인 비소세포성 폐암환자의 한방치료 증례보고)

  • Shim, So-hyun;Seo, Hee-jeong;Seo, Hyung-bum;Cho, Im-hak;Lee, Chan;Kim, So-yeon;Han, Chang-woo;Park, Seong-ha;Yun, Young-ju;Lee, In;Kwon, Jung-nam;Hong, Jin-woo;Choi, Jun-yong
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.4
    • /
    • pp.709-722
    • /
    • 2019
  • Objective: The purpose of this study was to report the effect of traditional Korean medicine (TKM) in alleviating the side effects of lung cancer patient undergoing immunotherapy. Method: A 43-year-old man, who was diagnosed with non-small cell lung cancer, received pembrolizumab treatments. The patient was treated with acupuncture and herbal medicine (Geoeoyangpye-tang) to control various uncomfortable symptoms. The degree of pain was measured by the numeric rating scale (NRS). The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire, Core 30 (EORTC QLQ-C30) and the EORTC 13-item lung cancer-specific module (EORTC LC-13 questionnaire) were used to assess the change in the quality of life. Results: After the TKM treatment, the flank pain and arthralgia based on the NRS were significantly improved. Various uncomfortable symptoms such as fatigue, dyspnea, insomnia, and loss of appetite were also significantly improved, based on the EORTC QLQ-C30 and EORTC QLQ-LC13. The size of the primary tumor was decreased during treatment. The disease status was stable radiologically after two months from discharge.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF

u-EMS : An Emergency Medical Service based on Ubiquitous Sensor Network using Bio-Sensors (u-EMS : 바이오 센서 네트워크 기반의 응급 구조 시스템)

  • Kim, Hong-Kyu;Moon, Seung-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.7
    • /
    • pp.433-441
    • /
    • 2007
  • The bio-Sensors, which are sensing the vital signs of human bodies, are largely used by the medical equipment. Recently, the sensor network technology, which composes of the sensor interface for small-seize hardware, processor, the wireless communication module and battery in small sized hardware, has been extended to the area of bio-senor network systems due to the advances of the MEMS technology. In this paper we have suggested a design and implementation of a health care information system(called u-EMS) using a bio-sensor network technology that is a combination of the bio-sensor and the sensor network technology. In proposed system, we have used the following vital body sensors such as EKG sensor, the blood pressure sensor, the heart rate sensor, the pulse oximeter sensor and the glucose sensor. We have collected various vital sign data through the sensor network module and processed the data to implement a health care measurement system. Such measured data can be displayed by the wireless terminal(PDA, Cell phone) and the digital-frame display device. Finally, we have conducted a series of tests which considered both patient's vital sign and context-awared information in order to improve the effectiveness of the u-EMS.

Evaluation of Power Generation Performance for Bifacial Si Photovoltaic Modules installed on Different Artificial Grass Floors (인조잔디 바닥종류에 따른 양면수광형 실리콘 태양광 모듈의 발전성능 평가)

  • Yoo, Younggyun;Seo, Yeongju;Park, Dohyun;Kim, Minsu;Jang, Hojun;Kwon, Young Hoon;Hwangbo, Chul;Kim, Woo Kyoung;Chang, Sungho
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, the outdoor evaluation test was performed to characterize the highly-reflective artificial grass to be used for bifacial photovoltaic (PV) power generation system. The 60-cell n-type Si monofacial and bifacial PV modules were employed, where two types of bifacial modules were equipped with split-type and box-type junction boxes, respectively. The results showed that the split-type junction box improved the rear-side power production and thus energy yield of bifacial module compared to the box-type junction box causing the shadow effect. Highly-reflective artificial grass achieved relatively high albedo of 0.18, and excellent bifacial gain of 33%, compared to conventional artificial grass with an albedo of 0.14-0.15, and bifacial gain of 29-30%.