• Title/Summary/Keyword: Module cell

Search Result 738, Processing Time 0.03 seconds

A Novel Simple Method to Abstract the Entire Parameters of the Solar Cell

  • Park, Minwon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.86-91
    • /
    • 2004
  • PV power generation, which directly converts solar radiation into electricity, contains numerous significant advantages. It is inexhaustible and pollution-free, silent, contains no rotating parts, and has size-independent electricity conversion efficiency. The positive environmental effect of photovoltaics is that it replaces the more polluting methods of electricity generation or that it provides electricity where none was available before. This paper highlights a novel simple method to abstract the entire parameters of the solar cell. In development, design and operation of PV power generation systems, a technique for constructing V-I curves under different levels of solar irradiance and cell temperature conditions using basic characteristic values of the PV module is required. Everyone who has performed manual acquisition and analysis of solar cell I versus V data would agree that the job is tedious and time-consuming. A better alternative is to use an automated curve tracer to print out the I versus V curves and compute the four major parameters; $V_{oc}$, $I_{sc}$, FF, and . Generally, the V-I curve tracer indicates only the commonly used solar cell parameters. However, with the conventional V-I curve tracer it is almost impossible to abstract the more detailed parameters of the solar cell; A, $R_{s}$ and $R_{sh}$ , which satisfies the user, who aims at the analysis of the development of the PV power generation system, that being advanced simulation. In this paper, the proposed method provides us with satisfactory results to enable us to abstract the detailed parameters of the solar cell; A, $R_s$ and $R_{sh}$.>.

Operating Characteristics of Advanced 500W class Anode-supported Flat Tubular SOFC stack in KIER (500W 급 연료극 지지체 평관형 고체산화물연료전지 스택의 운전 특성)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2007.11a
    • /
    • pp.193-198
    • /
    • 2007
  • KIER has been developing the anode supported flat tubular SOFC stack for the intermediate temperature $(700{\sim}800^{\circ}C)$ operation. for this purpose, we have first fabricated anode supported flat tubular cells by the optimization between the current collecting method and the induction brazing process. After that we designed the compact fuel & air manifold by adopting the simulation technique to uniformly supply fuel & air gas and the unique seal & insulation method to make the more compact stack. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90cm^2$ of connected in series with 12 modules, in which one module consists of two cells connected in parallel. The performance of stack in 3 % humidified $H_2$ and air at $800^{\circ}C$ shows maximum power of 507 W. Through these experiments, we obtained basic & advanced technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular SOFC stack in KIER.

  • PDF

Mitigation of Potential-Induced Degradation (PID) for PERC Solar Cells Using SiO2 Structure of ARC Layer (반사방지막(ARC)의 SiO2 구조에 따른 PERC 태양전지 PID 열화 완화 상관관계 연구)

  • Oh, Kyoung Suk;Park, Ji Won;Chan, Sung Il
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.114-119
    • /
    • 2020
  • In this study, Mitigation of Potential-induced degradation (PID) for PERC solar cells using SiO2 Structure of ARC layer. The conventional PID test was conducted with a cell-level test based on the IEC-62804 test standard, but a copper PID test device was manufactured to increase the PID detection rate. The accelerated aging test was conducted by maintaining 96 hours with a potential difference of 1000 V at a temperature of 60℃. As a result, the PERC solar cell of SiO2-Free ARC structure decreased 22.11% compared to the initial efficiency, and the PERC solar cell of the Upper-SiO2 ARC structure decreased 30.78% of the initial efficiency and the PID reliability was not good. However, the PERC solar cell with the lower-SiO2 ARC structure reduced only 2.44%, effectively mitigating the degradation of PID. Na+ ions in the cover glass generate PID on the surface of the PERC solar cell. In order to prevent PID, the structure of SiNx and SiO2 thin films of the ARC layer is important. SiO2 thin film must be deposited on bottom of ARC layer and the surface of the PERC solar cell N-type emitter to prevent surface recombination and stacking fault defects of the PERC solar cell and mitigated PID degradation.

Time-division hybrid WDM photonic switch architecture (시분할 하이브리드 WDM 광스위치 구조)

  • 김기태;엄진섭;김우찬;신서용;정홍식
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.5
    • /
    • pp.52-60
    • /
    • 1997
  • Photonic switching systems with throughput above Tbit/s are reuried to transport vast amounts of information for the coming B-ISDN. In this paper, we proposed a new time-division hybrid WDM photonic swithc architecture, the proposed basic switch module has simple configuratin consisted of frequency routers for wavelength division and cell coders and star couplers for time division. Through the comparison with other sysems in field of switching capacity, hardware complexity and cost effect of implemetnation, we proved that the proposed system is suitable for large-capacity photonic switching system.

  • PDF

Scheduling and simulation for FMC systems (FMC 시스템의 스케쥴링 및 시뮬레이션)

  • 서기성;이노성;안인석;박승규;이규호;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.370-375
    • /
    • 1992
  • This paper deals with the scheduling and simulation for FMC(Flexible Manufacturing Cells). In order to achieve CIM, there is a critical need to link factory level and machine level. The primary functions performed by this link for all jobs issued to the shop floor and cell include short-term scheduling and dynamic operational scheduling. Here, hierarchical control structure is introduced to define these functions. And Intelligent scheduling through expert module is adopted for efficiency of FMC operation. Computer simulation reveals that expert scheduling method is better than heuristics in various performance index.

  • PDF

Soft-switching Current Source Inverter for Interconnection of Solar Cell with Power System (태양전지의 개통연계를 위한 소프트스위칭 전류원 인버터)

  • Choy, Young-Do;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.345-347
    • /
    • 2000
  • This paper proses a soft-switching current-source inverter with a switched-capacitor module. The system operation was analyzed by a theoretical approach with equivalent circuits and verified by a computer simulation and experiment. The proposed system could be effectively applied for the power converter of photovoltaic power generation interconnected with the power system.

  • PDF

A Study on DC Arc Accident Detection Circuit of Solar Cell Module (태양전지 모듈의 DC 아크사고 감지회로에 관한 연구)

  • Jung, Min-Sang;Kwak, Dong-Kurl;Lee, Bong-Sub;Choi, Jung-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.546-548
    • /
    • 2019
  • Due to environmental problems, fossil fuel and nuclear power generation are declining and solar power generation is increasing. DC are of a solar power plant is accidents caused by accidents, causing damage to property and people. This study prevents DC are accidents of solar power modules. It is expected that the IoT will be used to quickly alert the manager and greatly contribute to fire prevention.

  • PDF

The Concentrating Photovoltaic System using a Solar Tracker (태양위치 추적 장치를 이용한 집광형 태양광 발전시스템)

  • Yoo, Yeong-tae;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.4
    • /
    • pp.377-385
    • /
    • 2017
  • The solar cell need the characteristic interpreting because the solar cell changes greatly according to the isolation, temperature and load in the photovoltaic development. Moreover, to get many energy in photovoltaic development need the position tracking of the sun according to the environment change. Also, The solar cells should be operated at the maximum power point. In this paper, I used microprocessor and sensor and designed to improve the efficiency of the photovoltaic system the photovoltaic position tracker device, and compared the normal photovoltaic system of fixed form with the photovoltaic system of solar position tracked form. Moreover, compared the catalogue of solar cell module and the simulation through a mathematics modelling with the solar cell's characteristic interpreting and composed an power conversion system with boost converter and voltage source inverter. Used the constant voltage control method for maximum power point tracking in boost converter control and, used the SPWM(Sinusoidal Pulse Width Modulation) control method in inverter control. The result was less then 5% when compared the catalogue of solar cell module and the simulation through a mathematics modelling. The boost rate of boost converter was similar to 167 % with the simulation.

Development of a Vegetation Buffer Strip Module for a Distributed Watershed Model CAMEL (유역모델 CAMEL 기반 식생여과대 모듈의 개발)

  • Park, Min-Hye;Cho, Hong-Lae;Koo, Bhon-Kyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.516-531
    • /
    • 2015
  • In this study, a software module to predict the effectiveness of vegetation buffer strip (VBS) has been developed for using with Chemicals, Agricultural Management and Erosion Losses (CAMEL), a distributed watershed model. Most basic functions for the VBS module are same as CAMEL except functions newly developed to implement sedimentation enhancement by vegetation and level spreaders. For verification of the VBS module, sensitivity analyses for length, roughness, soil and vegetation type of VBS were carried out using a test grid cell. The surface discharge of sediment are highly sensitive to the roughness coefficient of VBS. The removal efficiencies of VBS for the surface discharges of sediment and TP are generally high regardless of environment changes. The surface discharges of TOC and TN are highly sensitive to the length and soil of VBS. The removal efficiencies of VBS for the surface discharges of TOC and TN are generally lower than those of sediment and TP. The newly developed VBS module reasonably simulates the removal efficiencies of surface discharges that vary according to the environment changes. It is expected that this VBS module can be used for evaluating the effectiveness of VBS-based best management practices to be applied to reduce pollution discharges from various non-point sources.

A study on the Optimal Configuration Algorithm for Modeling and Improving the Performance of PV module (태양광모듈의 모델링 및 성능향상을 위한 최적구성방안에 관한 연구)

  • Jeong, Jong-Yun;Choi, Sung-Sik;Choi, Hong-Yeol;Ryu, Sang-Won;Lee, In-Cheol;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.723-730
    • /
    • 2016
  • Solar cells in a PV module are connected in series and parallel to produce a higher voltage and current. The PV module has performance characteristics depending on solar radiation and temperature. In addition, the PV system causes power loss by special situations, including the shadows of the surrounding environment, such as nearby buildings and trees. In other words, an increase in power loss and a decrease in life cycle can occur because of the partial shadow and hot-spot effect. Therefore, this paper proposes the optimal configuration algorithm of a bypass diode to improve the output of a PV module and one of a PV array to minimize the loss of the PV array. In addition, this paper presents a model of a PV module and PV array based on the PSIM S/W. The simulation results confirmed that the proposed optimal configuration algorithms are useful tools for improving the performance of PV system.