• 제목/요약/키워드: Modulation-Synchronized

검색결과 20건 처리시간 0.022초

Numerical Study on Laminar Flow over Three Side-by-Side Cylinders

  • Kang, Sangmo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1869-1879
    • /
    • 2004
  • The present study has numerically investigated two-dimensional flow over three circular cylinders in an equidistant side-by-side arrangement at a low Reynolds number. For the study, numerical simulations are performed, using the immersed boundary method, in the range of g* < 5 at Re= 100, where g* is the spacing between two adjacent cylinder surfaces divided by the cylinder diameter. Results show that the flow characteristics significantly depend on the gap spacing and a total of five kinds of wake patterns are observed over the range: modulation-synchronized (g* (equation omitted) 2), inphase-synchronized (g* (equation omitted) 1.5) , flip-flopping (0.3 < g* (equation omitted) 1.2) , deflected (g* (equation omitted) 0.3), and single bluff-body patterns (g* < 0.3). Moreover, the parallel and symmetric modes are also observed depending on g* in the regime of the flip-flopping pattern. The corresponding flow fields and statistics are presented to verify the observations.

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.

PV효과를 이용한 전압형 인버어터 전원동기 전압 조정기에 관한 연구 (A Study on Synchronized AC Power Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic effect)

  • 황락훈
    • 전자공학회논문지S
    • /
    • 제35S권8호
    • /
    • pp.120-129
    • /
    • 1998
  • 본 논문은 PWM(Pulse width Modulation)전압형 인버어터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원장치에 대해 논하였다. 본 시스템은 전압형 인버어터를 교류전원과 동기시켜 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인할 수 있었다.

  • PDF

Comparative Study on SVPWM Switching Sequences for VSIs

  • Vivek, G.;Biswas, Jayanta;Nair, Meenu D.;Barai, Mukti
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.133-142
    • /
    • 2018
  • Paper presents a comparative study of space vector pulse width modulation (SVPWM) switching sequences for Voltage Source Inverters (VSIs). Various SVPWM switching sequences are studied for two and three level VSIs in linear modulation index region. The computations of dwell times are presented for two and three level VSIs based on space vector geometry in a synchronized and optimized manner. The existing SVPWM switching sequences are implemented using Matlab / Simulink and in an experimental setup for three phase two and three level VSIs. The simulation and experimental waveforms of conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are demonstrated for two and three level inverter respectively. The performance of different SVPWM switching sequences are evaluated and presented based on weighted voltage total harmonic distortion (THD).

공간벡터 PWM 방식을 이용한 태양광 발전 시스템 제어 (Photovoltaic Generation System Control Using Space Vector PWM Method)

  • 조문택;최혜길;이충식;백종무
    • 한국방사선학회논문지
    • /
    • 제4권3호
    • /
    • pp.31-37
    • /
    • 2010
  • 본 논문에서는 태양광 발전시스템을 이용한 PWM(Pulse Width Modulation) 전압형 인버터를 전력변환기로 구성하였고, 안정된 변조를 위해서 동기신호와 제어신호를 56F8323 마이크로프로세서에 의해서 처리하였다. PWM 전압형 인버터는 태양전지가 연속 발전할 수 없는 단점을 보완하기 위해 일반 상용전원과 연계함으로써 약 10~20[%]의 전력 절감 효과를 얻을 수 있는 에너지 절약 전원 복합형 전력변환장치로 구성하였다. 그리고 PWM 전압형 인버터와 위상동기를 위해서 계통전압을 검출하고 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 계통과 연계할 수 있게 하였다. 또한, 고조파를 절감한 출력을 유지함으로써 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어 시스템을 적용하여 좋은 결과를 얻을 수 있었다.

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF

윈도우 기반 심벌 타이밍 복원 (Window based Symbol Timing Recovery)

  • 이철수;장승현;정의석;김병휘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.487-489
    • /
    • 2005
  • This paper proposes a symbol timing recovery method that is simple in structure and can provide high speed symbol synchronization. Transmitter and receiver are not synchronized in communication systems using digital modulation. Receiver should search the timing variation of transmitter continuously. The proposed timing recovery method searches sample position by comparing previous sample value with next sample value. This method can be applied to digital and optical transceivers with high data rate.

  • PDF

계통 연계형 태양광 발전시스템의 전력변환기 제어에 관한 연구 (A Study on the Power Converter Control of Utility Interactive Photovoltaic Generation System)

  • 나승권;구기준;김계국
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.157-168
    • /
    • 2009
  • 본 논문에서는 태양광 발전시스템을 이용한 승압 초퍼와 전압형 PWM(Pulse Width Modulation) 인버터인 전력변환기로 구성하였고, 안정된 변조를 위해서 동기신호와 제어신호를 원칩 마이크로프로세서에 의해서 처리하였다. 전력비교에 따라 시간 비율을 변화시키지만 태양전지는 전형적인 수하특성을 갖고 있어, 일사량과 온도변화에 관계없이 항상 최대 출력점을 추적하도록 승압초퍼를 제어하였다. 또한 PWM 전압형 인버터는 태양전지가 연속 발전할 수 없는 단점을 보완하기 위해 일반 상용전원과 연계함으로써 약 $10{\sim}20[%]$ 전력절감효과를 얻을 수 있는 에너지절약 전원 복합형 전력변환장치로 구성하였다. 그리고 태양광 발전의 효율을 높이기 위하여 센서와 마이크로프로세서를 이용한 태양광위치추적 장치를 설계하여 고정방식의 태양광 발전에 대하여 비교해 보았다. 그 결과, 태양광 위치추적장치는 고정방식의 태양광 발전에 비해 5% 정도 개선됨을 알 수 있었다. 또한, PWM 전압형 인버터와 위상동기를 위해서 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 계통과 연계할 수 있게 하였다. 그리고 고역율과 저고조파 출력을 유지함으로서 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어하였다.

재생형 위상 변조에 의한 '8'자 구조 광섬유 솔리톤 레이저의 고차 조화 모드록킹 (Harmonic mode locking of 'Figure-of-Eight' fiber soliton laser using regenerative phase modulation)

  • 윤승철;박희갑
    • 한국광학회지
    • /
    • 제10권2호
    • /
    • pp.146-151
    • /
    • 1999
  • 고반복률의 안정된 솔리톤 펄스열 출력을 얻기 위해 재생형 위상 변조에 의한 고차 조화 모드록킹 방식을‘8’구조 광섬유 레이저에 적용하고 실험하였다. 레이저 펄스 출력의 종모드간 맥놀이 스펙트럼으로부터 모드록킹 기본 주파수의 96차 고조파인 400 MHz 성분을 추출하고. 이를 증폭하여 공진기 내의 위상 변조기를 구동함으로써 변조기의 변조 신호에 따라 등간격으로 정렬된 솔리톤 펄스열 출력을 얻을 수 있었다. 이때 솔리톤 펄스의 반치폭 930 fs, 반치 파장선폭은 3.1 nm 였으며, 펄스폭과 주파수 대역폭의 곱이 0.359로써 변환한계에 가까운 솔리톤 펄스임을 알 수 있었다. 변조 주파수가 레이저의 종모드간 주파수 차이와 언제나 정확히 일치하므로 능동형 모드록킹에서 흔히 요구되는 공진기 길이의 조절없이도 안정적인 고차 조화 모드록킹이 가능하였다.

  • PDF

차음성능 측정에 있어서의 암소음의 영향의 저감 (1) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.495-498
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined by a simple sound insulation measurement.

  • PDF