• Title/Summary/Keyword: Modified Gates method

Search Result 11, Processing Time 0.026 seconds

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

A Gate Modification Method Using the Input Vector Maximizes the Number of Gates in WLS within the Optimum Range (최적 범위내에서 WLS인 게이트 수가 최대가 되는 입력 벡터를 이용한 게이트 수정 기법)

  • Sung, Bang-Hyun;Park, Hyae-Seong;Kim, Seok-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.745-750
    • /
    • 2007
  • In this paper, we propose a new gate modification method using the input vector maximizes the number of gates in WLS within the optimum range of the minimum leakage power. We prove that MLV is not always the optimal solution, and that the leakage power and area can decrease when modifying the gates using the input vector for which the number of gates in WLS is maximized within the optimum range of the minimum leakage power for the circuits applying the IVC technique and gate modification method. Using the proposed method, the gate-level description circuit can be converted to the modified circuit which reduces the leakage power by chip designer, and the modified circuit can be applied without any modification in design flow.

사출성형의 게이트 위치 최적화

  • Lim, Won-Gil;Kim, Young-Il;Seol, Kwon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.787-791
    • /
    • 1996
  • In injection molding, location of gates have great influence on the quality of plastic parts. Usually, they are located by releated trial and errors of experienced mold designers. In this topic we will present the numerical algorithm for finding the optimal gate locations. Optimization algorithm is devided into two stages. In the first stage, candidated optimal gate locations can be found by geometry of part only; whereas in the next step, more acculate gate locations are selected byiterative computation with optimization part and analysis part. So from the following study, we suggested the modified flow-volume method, which will define the optimal gate locations in injection mold design.

  • PDF

Efficient ROM Size Reduction for Distributed Arithmetic (벡터 내적을 위한 효율적인 ROM 면적 감소 방법)

  • 최정필;성경진;유경주;정진균
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.821-824
    • /
    • 1999
  • In distributed arithmetic-based architecture for an inner product between two length-N vectors, the size of the ROM increases exponentially with N. Moreover, the ROMs are generally the bottleneck of speed, especially when their sire is large. In this paper, a ROM size reduction technique for DA (Distributed Arithmetic) is proposed. The proposed method is based on modified OBC (Offset Binary Coding) and control circuit reduction technique. By simulations, it is shown that the use of the proposed technique can result in reduction in the number of gates up to 50%.

  • PDF

Logic Circuit Fault Models Detectable by Neural Network Diagnosis

  • Tatsumi, Hisayuki;Murai, Yasuyuki;Tsuji, Hiroyuki;Tokumasu, Shinji;Miyakawa, Masahiro
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.154-157
    • /
    • 2003
  • In order for testing faults of combinatorial logic circuit, the authors have developed a new diagnosis method: "Neural Network (NN) fault diagnosis", based on fm error back propagation functions. This method has proved the capability to test gate faults of wider range including so called SSA (single stuck-at) faults, without assuming neither any set of test data nor diagnosis dictionaries. In this paper, it is further shown that what kind of fault models can be detected in the NN fault diagnosis, and the simply modified one can extend to test delay faults, e.g. logic hazard as long as the delays are confined to those due to gates, not to signal lines.

  • PDF

Efficient ROM Size Reduction for Distributed Arithmetic (벡터 내적을 위한 효율적인 ROM 면적 감소 방법)

  • 최정필;성경진;유경주;정진균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3B
    • /
    • pp.584-591
    • /
    • 2000
  • In distributed arithmetic-based architecture for an inner product between two length-N vectors, the size of the ROM increases exponentially with N. Moreover, the ROMs are generally the bottleneck of speed, especially when their size is large. In this paper, a ROM size reduction technique for DA( distributed arithmetic ) is proposed. The proposed method is based on modified OBC( offset binary coding) and control circuit reduction technique. by simulations, it is shown that the use of the proposed technique can result in reduction in the number of gates up to 50%.

  • PDF

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

A Study on the Allowable Bearing Capacity of Pile by Driving Formulas (각종 항타공식에 의한 말뚝의 허용지지력 연구)

  • 이진수;장용채;김용걸
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.03a
    • /
    • pp.197-203
    • /
    • 2002
  • The estimation of pile bearing capacity is important since the design details are determined from the result. There are numerous ways of determining the pile design load, but only few of them are chosen in the actual design. According to the recent investigation in Korea, the formulas proposed by Meyerhof based on the SPT N values are most frequently chosen in the design stage. In the study, various static and dynamic formulas have been used in predicting the allowable bearing capacity of a pile. Further, the reliability of these formulas has been verified by comparing the perdicted values with the static and dynamic load test measurements. Also in cases, these methods of pile bearing capacity determination do not take the time effect consideration, the actual allowable load as determined from pile load test indicates severe deviation from the design value. The principle results of this study are summarized as follows : A a result of estimate the reliability in criterion of the Davisson method, in was showed that Terzaghi & Peck > Chin > Meyerhof > Modified Meyerhof method was the most reliable method for the prediction of bearing capacity. Comparisons of the various pile-driving formulas showed that Modified Engineering News was the most reliable method. However, a significant error happened between dynamic bearing capacity equation was judged that uncertainty of hammer efficiency, characteristics of variable , time effect etc... was not considered. As a result of considering time effect increased skin friction capacity higher than end bearing capacity. It was found out that it would be possible to increase the skin friction capacity 1.99 times higher than a driving. As a result of considering 7 day's time effect, it was obtained that Engineering News. Modified Engineering News. Hiley, Danish, Gates, CAPWAP(CAse Pile Wave Analysis Program ) analysis for relation, respectively, $Q_{u(Restrike)}$ $Q_{u(EOID)}$ = 0.971 $t_{0.1}$, 0.968 $t_{0.1}$, 1.192 $t_{0.1}$, 0.88 $t_{0.1}$, 0.889 $t_{0.1}$, 0.966 $t_{0.1}$, 0.889 $t_{0.1}$, 0.966 $t_{0.1}$

  • PDF

An Efficient Test Pattern Generator for Low Power BIST (내장된 자체 테스트를 위한 저전력 테스트 패턴 생성기 구조)

  • Kim, Ki-Cheol;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.29-35
    • /
    • 2010
  • In this paper we propose a new pattern generator for a BIST architecture that can reduce the power consumption during test application. The principle of the proposed method is to reconstruct an LFSR circuit to reduce WSAs of the heavy nodes by suppressing the heavy inputs. We propose algorithms for finding heavy nodes and heavy inputs. Using the Modified LFSR which consists of some AND/OR gates trees and an original LFSR, BIST applies modified test patterns to the circuit under test. The proposed BIST architecture with small hardware overhead effectively reduces the average power consumption during test application while achieving high fault coverage. Experimental results on the ISCAS benchmark circuits show that average power reduction can be achieved up to 30.5%.

All-Optical Gray Code to Binary Coded Decimal Converter (전광 그레이코드 이진코드 변환기)

  • Jung, Young-Jin;Park, Nam-Kyoo;Jhon, Young-Min;Woo, Deok-Ha;Lee, Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • An all-optical 4-bit Gray code to binary coded decimal (BCD) converter by means of commercially available numerical analysis tool (VPI) was demonstrated, for the first time to our knowledge. Circuit design approach was modified appropriately in order to fit the electrical method on an all-optical logic circuit based on a cross gain modulation (XGM) process so that signal degradation due to the non-ideal optical logic gates can be minimized. Without regenerations, Q-factor of around 4 was obtained for the most severely degraded output bit (least significant bit-LSB) with 2.5 Gbps clean input signals having 20 dB extinction ratio. While modifying the two-level simplification method and Karnaugh map method to design a Gray code to BCD converter, a general design concept was also founded (one-level simplification) in this research, not only for the Gray code to BCD converter but also for any general applications.