• Title/Summary/Keyword: Model surgery

검색결과 1,540건 처리시간 0.025초

Genioplasty using a simple CAD/CAM (computer-aided design and computer-aided manufacturing) surgical guide

  • Lim, Se-Ho;Kim, Moon-Key;Kang, Sang-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.44.1-44.6
    • /
    • 2015
  • Background: The present study introduces the design and fabrication of a simple surgical guide with which to perform genioplasty. Methods: A three-dimensional reconstruction of the patient's cranio-maxilla region was built, with a dentofacial skeletal model, then derived from CT DICOM data. A surgical simulation was performed on the maxilla and mandible, using three-dimensional cephalometry. We then simulated a full genioplasty, in silico, using the three-dimensional (3D) model of the mandible, according to the final surgical treatment plan. The simulation allowed us to design a surgical guide for genioplasty, which was then computer-rendered and 3D-printed. The manufactured surgical device was ultimately used in an actual genioplasty to guide the osteotomy and to move the cut bone segment to the intended location. Results: We successfully performed the osteotomy, as planned during a genioplasty, using the computer-aided design and computer-aided manufacturing (CAD/CAM) surgical guide that we initially designed and tested using simulated surgery. Conclusions: The surgical guide that we developed proved to be a simple and practical tool with which to assist the surgeon in accurately cutting and removing bone segments, during a genioplasty surgery, as preoperatively planned during 3D surgical simulations.

Comparison of the trometamol-balanced solution with two other crystalloid solutions for fluid resuscitation of a rat hemorrhagic model

  • Ting, Wen-Ting;Chang, Ru-Wen;Wang, Chih-Hsien;Chen, Yih-Sharng;Lee, Jih-Jong
    • Journal of Veterinary Science
    • /
    • 제21권1호
    • /
    • pp.6.1-6.12
    • /
    • 2020
  • Currently, the optimal resuscitation fluid remains debatable. Therefore, in the present study, we designed a trometamol-balanced solution (TBS) for use as a resuscitation fluid for hemorrhagic shock. Hemorrhagic shock was induced in 18 male Wistar-Kyoto rats, which were assigned to normal saline (NS), Ringer's solution (RS), and TBS groups. During the hemorrhagic state, their hemodynamic parameters were recorded using an Abbott i-STAT analyzer with the CG4+ cartridge (for pH, pressure of carbon dioxide, pressure of oxygen, total carbon dioxide, bicarbonate, base excess, oxygen saturation, and lactate), the CG6+ cartridge (for sodium, potassium, chloride, blood glucose, blood urea nitrogen, hematocrit, and hemoglobin), and enzyme-linked immunosorbent assay kits (calcium, magnesium, creatinine, aspartate aminotransferase, alanine aminotransferase, bilirubin, and albumin). Similar trends were found for the parameters of biochemistries, electrolytes, and blood gas, and they revealed no significant changes after blood withdrawal-induced hemorrhagic shock. However, the TBS group showed more effective ability to correct metabolic acidosis than the NS and RS groups. TBS was a feasible and safe resuscitation solution in this study and may be an alternative to NS and RS for resuscitation in hemorrhagic shock patients without liver damage.

Mandible Reconstruction with 3D Virtual Planning

  • Woo, Taeyong;Kraeima, Joep;Kim, Yong Oock;Kim, Young Seok;Roh, Tai Suk;Lew, Dae Hyun;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.90-93
    • /
    • 2015
  • The fibula free flap has now become the most reliable and frequently used option for mandible reconstruction. Recently, three dimensional images and printing technologies are applied to mandibular reconstruction. We introduce our recent experience of mandibular reconstruction using three dimensionally planned fibula free flap in a patient with gunshot injury. The defect was virtually reconstructed with three-dimensional image. Because bone fragments are dislocated from original position, relocation was necessary. Fragments are virtually relocated to original position using mirror image of unaffected right side of the mandible. A medical rapid prototyping (MRP) model and cutting guide was made with 3D printer. Titanium reconstruction plate was adapted to the MRP model manually. 7 cm-sized fibula bone flap was designed on left lower leg. After dissection, proximal and distal margin of fibula flap was osteotomized by using three dimensional cutting guide. Segmentation was also done as planned. The fibula bone flap was attached to the inner side of the prebent reconstruction plate and fixed with screws. Postoperative evaluation was done by comparison between preoperative planning and surgical outcome. Although dislocated condyle is still not in ideal position, we can see that reconstruction was done as planned.

Different DLCO Parameters as Predictors of Postoperative Pulmonary Complications in Mild Chronic Obstructive Pulmonary Disease Patients with Lung Cancer

  • Mil Hoo Kim;Joonseok Lee;Joung Woo Son;Beatrice Chia-Hui Shih;Woohyun Jeong;Jae Hyun Jeon;Kwhanmien Kim;Sanghoon Jheon;Sukki Cho
    • Journal of Chest Surgery
    • /
    • 제57권5호
    • /
    • pp.460-466
    • /
    • 2024
  • Background: Numerous studies have investigated methods of predicting postoperative pulmonary complications (PPCs) in lung cancer surgery, with chronic obstructive pulmonary disease (COPD) and low forced expiratory volume in 1 second (FEV1) being recognized as risk factors. However, predicting complications in COPD patients with preserved FEV1 poses challenges. This study considered various diffusing capacity of the lung for carbon monoxide (DLCO) parameters as predictors of pulmonary complication risks in mild COPD patients undergoing lung resection. Methods: From January 2011 to December 2019, 2,798 patients undergoing segmentectomy or lobectomy for non-small cell lung cancer (NSCLC) were evaluated. Focusing on 709 mild COPD patients, excluding no COPD and moderate/severe cases, 3 models incorporating DLCO, predicted postoperative DLCO (ppoDLCO), and DLCO divided by the alveolar volume (DLCO/VA) were created for logistic regression. The Akaike information criterion and Bayes information criterion were analyzed to assess model fit, with lower values considered more consistent with actual data. Results: Significantly higher proportions of men, current smokers, and patients who underwent an open approach were observed in the PPC group. In multivariable regression, male sex, an open approach, DLCO <80%, ppoDLCO <60%, and DLCO/VA <80% significantly influenced PPC occurrence. The model using DLCO/VA had the best fit. Conclusion: Different DLCO parameters can predict PPCs in mild COPD patients after lung resection for NSCLC. The assessment of these factors using a multivariable logistic regression model suggested DLCO/VA as the most valuable predictor.

추계적 계획법을 이용한 수술실 예약 모델과 Newsvendor 비율의 자원 효율성에 대한 영향 분석 (Stochastic Programming Approach to Scheduling Elective Surgeries and the Effects of Newsvendor Ratio on Operating Room Utilization)

  • 민대기
    • 경영과학
    • /
    • 제28권2호
    • /
    • pp.17-29
    • /
    • 2011
  • The purpose of this paper is to schedule elective surgery patients using a stochastic programming approach and to illustrate how operating room utilization behaves when a decision-maker varies costs associated with utilization. Because of the uncertainty in surgery durations, the underage and overage costs that a decision-maker considers plays an important role in allocating surgery cases into available operating room capacity. We formulate the problem as a stochastic mixed integer programming and propose a sampling-based approximation method for a computational purpose. Newsvendor model is employed to explain the results from numerical experiments that are conducted with the actual data from a hospital. The results show that the operating room utilization is more sensitive when the unit overtime cost is relatively larger than the unit cost for underutilized time.

Surgical Jaw Relator를 이용한 Surgical splint의 제작 (FABRICATION OF SURGICAL SPLINT BY USING OF SURGICAL JAW RELATOR)

  • 양상덕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.188-195
    • /
    • 2005
  • After making the surgical treatment plan, the surgical movements are duplicated in the model surgery. During this procedure, reference points and lines are drawn on the base of the models over the dental arch, and sawcuts are made according to these marked osteotomy lines. This method requires more accuracy for better postsurgical results in that the surgical splint which enables the surgeon to position the jaws intraoperatively is made from the casts as repositioned by the model surgery, and finally it will define the postsurgical results. This technique, however, has been found to be inexact, especially when the jaws are moved in several dimensions simultaneously. To overcome this, different methods have been developed for an accurate repositioning of the jaws as planned. A new appliance, Surgical Jaw Relator, was devised by the author for the simple 3-dimensional relocation of the upper and lower models, resulting in the easy construction of the splints such as centric relation splint, intermediate and final splint. This article describes an introduction and a clinical application of this appliance.

In Vivo Neuroprotective Effect of Histidine-Tryptophan-Ketoglutarate Solution in an Ischemia/Reperfusion Spinal Cord Injury Animal Model

  • Kang, Shin Kwang;Kang, Min-Woong;Rhee, Youn Ju;Kim, Cuk-Seong;Jeon, Byeong Hwa;Han, Sung Joon;Cho, Hyun Jin;Na, Myung Hoon;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • 제49권4호
    • /
    • pp.232-241
    • /
    • 2016
  • Background: Paraplegia is a devastating complication following operations on the thoracoabdominal aorta. We investigated whether histidine-tryptophan-ketoglutarate (HTK) solution could reduce the extent of ischemia/reperfusion (IR) spinal cord injuries in a rat model using a direct delivery method. Methods: Twenty-four Sprague-Dawley male rats were randomly divided into four groups. The sham group (n=6) underwent a sham operation, the IR group (n=6) underwent only an aortic occlusion, the saline infusion group (saline group, n=6) underwent an aortic occlusion and direct infusion of cold saline into the occluded aortic segment, and the HTK infusion group (HTK group, n=6) underwent an aortic occlusion and direct infusion of cold HTK solution into the occluded aortic segment. An IR spinal cord injury was induced by transabdominal clamping of the aorta distally to the left renal artery and proximally to the aortic bifurcation for 60 minutes. A neurological evaluation of locomotor function was performed using the modified Tarlov score after 48 hours of reperfusion. The spinal cord was harvested for histopathological and immunohistochemical examinations. Results: The spinal cord IR model using direct drug delivery in rats was highly reproducible. The Tarlov score was 4.0 in the sham group, $1.17{\pm}0.75$ in the IR group, $1.33{\pm}1.03$ in the saline group, and $2.67{\pm}0.81$ in the HTK group (p=0.04). The histopathological analysis of the HTK group showed reduced neuronal cell death. Conclusion: Direct infusion of cold HTK solution into the occluded aortic segment may reduce the extent of spinal cord injuries in an IR model in rats.

혈관문합 연습을 위한 보존된 복재정맥의 활용 (Microsurgical Training using Preserved Saphenous Vein)

  • 송제니퍼김;황소민;임광열;정용휘
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.391-395
    • /
    • 2010
  • Purpose: Given that the critical nature of the microvascular anastomosis to what is often a long and difficult reconstructive operation, trainees need to have a high level of microsurgical competence before being allowed to perform microsurgery on patients. Some artificial substitutes and dead or live animal models have been used to improve manual dexterity under the operating microscope. Yet, most surgeons are not equipped with such models, so search for easy available and appropriate microsurgical practice model have been an issue. Umbilical artery, placental vessels and gastroepiploic arteries have been previously suggested as a microsurgical training model, which involves other surgical departments. The purpose of this article is to introduce that saphenous vein specimen obtained from varicose vein surgery is useful and has many advantages as training model for the practice of microvascular anastomosis. Methods: The conventional technique using perforation/inversion method with a metallic stripper is widely performed for varicose vein patients. The stripper is inserted through disconnected safeno-femoral junction and retrieved at the knee or the medial side of ankle. The length of saphenous vein specimens removed is about that of one's leg and inversed from inside out. Obtained saphenous vein specimens are re-inversed and cleansed with normal saline, to be readily available for microsurgical practice. Preserved in a squeezed wet saline gauze and refrigerated, frozen or glycerated specimens were investigated into their comparative quality for microsurgical practice. Results: Varicose vein surgery remains one of the common operations performed in the field of plastic surgery. Convenient informed consent regarding the vessel donation can be easily signed. The diameter of the obtained saphenous vein is as variable as 1.5 to 6 mm, which is already stripped, and is in sufficient length corresponding to that of patient's leg. Vessels specimens were available for microsurgical practice within 1 week period when preserved with squeezed wet saline gauze, and the preservation period could be extended monthly by freezing it. Conclusion: Saphenous vein obtained from varicose vein patients provide with variable size of vessel lumen with sufficient length. The practice can be cost effective and does not require microsurgical laboratory. Additionally there is no need of involving other surgical departments in acquiring vessel specimens. Furthermore, simple preservation method of refrigerating for a week or freezing with squeezed wet saline gauze for a month period, allow the saphenous vein obtained after varicose vein surgery as an excellent model for the microsurgical practice.

보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가 (Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer)

  • 오왕균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.203-209
    • /
    • 2014
  • 쇄골 CT 영상을 이용하여 보급형 3D 프린터로 제작된 모델로 사전 수술계획을 실시하여 수술효율에 대한 유용성과 임상적 활용가능성을 평가하였다. CT 영상을 Open Source DICOM Viewer Osirix에서 STL 파일로 변환하여 FDM 와이어 척층가공방식의 보급형 3D 프린터로 환자 맞춤형 쇄골 골절 모델을 제작하였다. 또한, 인체의 좌우 대칭 특성을 이용하여 골절되지 않은 반대편 쇄골의 STL 파일을 Mirror 기법으로 손상되기 전 원형의 모델을 복원, 제작하였다. 모델은 골절의 위치와 크기, 정도가 동일하게 출력되었다. 영상의학과에서 적은 비용과 시간으로 직접 제작한 쇄골 모델을 활용하면 수술시 2차 손상을 줄이고, 최소 침습적 피하금속판 골유합술(MIPO)로 수술효율을 높일 수 있어 임상적으로 유용할 것으로 생각된다.

Hemifacial Transplantation Model in Rats

  • Lim, Jong Woo;Eun, Seok Chan
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.89-93
    • /
    • 2014
  • Background: To refine facial transplantation techniques and achieve sound results, it is essential to develop a suitable animal model. Rat is a small animal and has many advantages over other animals that have been used as transplantation models. The purpose of this study was to describe a rat hemifacial transplantation model and to verify its convenience and reproducibility. Methods: Animals used in this study were Lewis rats (recipients) and Lewis-Brown Norway rats (donors). Nine transplantations were performed, requiring 18 animals. The hemifacial flap that included the ipsilateral ear was harvested based on the unilateral common carotid artery and external jugular vein and was transferred as a single unit. Cyclosporine A therapy was initiated 24 hours after transplantation and lasted for 2 weeks. Signs of rejection responses were evaluated daily. Results: The mean transplantation time was 1 hour 20 minutes. The anatomy of common carotid artery and external jugular vein was consistent, and the vessel size was appropriate for anastomosis. Six of nine allografts remained good viable without vascular problems at the conclusion of study (postoperative 2 weeks). Conclusion: The rat hemifacial transplantation model is suitable as a standard transplantation training model.