• Title/Summary/Keyword: Mode reduction

Search Result 1,253, Processing Time 0.031 seconds

A New Electrode Structure for Color-shift Reduction in PVA LCD

  • Kwon, Yong-Hoan;Baek, Jong-In;Kim, Jae-Chang;Yoon, Tae-Hoon
    • Journal of Information Display
    • /
    • v.8 no.3
    • /
    • pp.17-21
    • /
    • 2007
  • We introduce a new electrode structure for the patterned vertical alignment (PVA) mode, which has a lower color-shift at large viewing angle than the one-domain VA mode. By manipulating the period of electrode structure, we can make more multi-domains and use the existing fabrication processes without having to use additional materials.

A Low Power scan Design Architecture (저전력을 고려한 스캔 체인 구조 변경)

  • Min, Hyoung-Bok;Kim, In-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.7
    • /
    • pp.458-461
    • /
    • 2005
  • Power dissipated during test application is substantially higher than power dissipated during functional operation which can decrease the reliability and lead to yield loss. This paper presents a new technique for power minimization during test application in full scan sequential circuits. This paper shows freezing of combinational logic parts during scan shift operation in test mode. The freezing technique leads to power to minimization. Significant power reduction in the scan techniques is achieved on ISCAS 89 benchmarks.

Characteristic Analysis of Noise Filter (노이즈필터의 특성 해석)

  • Kwon, Jin-Uk;Min, Een-Kyu;Youn, Duck-Yong;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.794-796
    • /
    • 1993
  • This paper deals with the characteristic analysis of noise filter for the reduction of conduction noise, especially, common-mode noise. Attenuation in the system containing noise filter is analyzed and equivalent circuits for common- and differential- mode noise are derived. To clarify the effects by parasitic components of the inductor and capacitor, digital simulations using Design Center are carried out.

  • PDF

Vibration Reduction By Dynamic Absorber of Vertical Pump System (동흡진기를 통한 수직펌프의 진동 저감)

  • 배춘희;조철환;양경현;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.628-632
    • /
    • 2001
  • In this paper, Firstly, it is shown that the bending mode vibration source of vertical pump system is comparatively large because resonance. Secondly in order to the bending mode vibration of vertical pump some practical dynamic absorber have been developed and its effectiveness is investigated as installing it at the vertical pump system practically.

  • PDF

Vibration Reduction of Pump and Piping System (대형펌프 토출배관계에서 발생하는 진동 저감)

  • Bae, Chun-Hee;Won, Jong-Bum;Cho, Cheul-Whan;Kim, Soung-Hye;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.145-149
    • /
    • 2000
  • In this paper, Firstly, it is shown that the bending mode vibration of check valve is comparatively large because resonance. Secondly in order to decrese the bending mode vibration of check valve, some practical dynamic vibration absorber have been developed and its effectiveness is investigated as installing it at the check valve of piping system practically.

  • PDF

Performance Comparison of Common-Mode Voltage Reduction Methods in terms of Modulation Index (변조지수에 따른 공통모드 전압 저감 기법 성능 비교)

  • Heo, Geon;Park, Yongsoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.106-108
    • /
    • 2020
  • This paper introduces a new pulse-width modulation (PWM) method to reduce common-mode voltages (CMVs) and compare its performance with other reduced CMV-PWM (RCMV-PWM) methods. To avoid the use of zero-vectors which cause high CMV peaks, the introduced method splits every reference vector into two vectors such that the peak-to-peak magnitude of CMV is reduced by one-third of conventional space-vector PWM (SVPWM). The performance of RCMV-PWMs altered by the modulation index are analyzed with simulation results.

  • PDF

Vibration Characterization of Cross-ply Laminates Beam with Fatigue Damage (피로 손상을 입은 직교 복합재료 적층보의 진동 특성)

  • 문태철;김형윤;황운봉;전시문;김동원;김현진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.1-4
    • /
    • 2001
  • A new non-destructive fatigue prediction model of the composite laminates is developed. The natural frequencies of fatigue-damaged laminates under extensional loading are related to the fatigue lift of the laminates by establishing the equivalent flexural stiffness reduction as a function of the elastic properties of sublaminates. The flexural stiffness is derived by relating the $90^{\circ}$-ply elastic modulus reduction, and using the laminate plate theory to the degraded elastic modulus and the intact elastic modulus of other laminate. The natural frequency reduction model, in which the dominant fatigue mode can be identified from the sensitivity scale factors of sublaminate elastic properties, provides natural frequency vs. fatigue cycle curves for the composite laminates. Vibration tests were also conducted on $[\textrm{90}_{2}\textrm{0}_{2}]_s$ carbon/epoxy laminates to verify the natural frequency reduction model. Correlations between the predictions of the model and experimental results are good.

  • PDF

Model Reduction Considering Both Resonances and Antiresonances (공진과 반공진 특성을 동시고려한 모델 축소)

  • 허진석;이시복;이창일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.985-990
    • /
    • 2001
  • The Frequency Response Function(FRF)s of FE Model reduced by SEREP methods accurately estimate the full model at resonance frequencies, However these FRFs are not accurate at antiresonance frequencies, Additionally, the truncation errors may he significant in the reduction mode1. So this paper considers the possibility of SERFP method through a numerical method to preserve dynamic behavior at antiresonance and appliers the static or dynamic compensation methods for truncation errors to the reduction model. This compensated reduction model is redesigned for pole-zero cancellation methods the objective of reducing a resonance frequency.

  • PDF

An Investigation of Performance Change of Diesel Oxidation Catalyst for Diesel Vehicle (경유차 적용 디젤산화촉매장치의 성능 변화 분석)

  • Hwang, Jin-Woo;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • This paper is to investigated the analysis of performance characteristics of diesel oxidation catalyst (DOC) for diesel vehicle with 2.5L piston displacement. The performance evaluation test of DOC applied to test diesel vehicle was carried out for four kinds of DOCs manufactured from different company. The testing DOCs were randomly selected from the retrofit vehicle and then standard test vehicle that was representative for the application group was equipped with DOC for the test. In this verification test, the reduction rate of particulate matter (P.M.) and the deviation of the performance of the DOC were examined through CVS-75 mode of the standard vehicle and SOF reduction rate of specific DOC was investigated. It was found that some DOCs failed to pass the criteria of the P.M. reduction rate because of the reason seen catalyst aging even if they were same devices. In the result of SOF analysis, the specific DOC showed more PM reduction than SOF of PM. reduction exceptionally.

  • PDF

Additive Noise Reduction Algorithm for Mass Spectrum Analyzer (질량 스펙트럼 분석기를 위한 부가잡음제거 알고리즘)

  • Choi, Hun;Lee, Imgeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • An additive noise reduction algorithm for a mass spectrum analyzer is proposed. From the measured ion signal, we first used an estimated threshold from the mode of the measured signal to eliminate background noises with the white Gaussian characteristics. Also, a signal block corresponding to each mass index is constructed to perform a second order curve fitting and a linear approximation to signal block. In this process, the effective signal block composed of only the ion signal can be reconstructed by removing the impulsive noises and the sample signals which are insufficient to be viewed as normal ion signals. By performing curve fitting on the effective signal block, the noise-free mass spectrum can be obtained. To evaluate the performance of the proposed method, a simulation was performed using the signals acquired from the development equipment. Simulation results show the validity of the threshold setting from the mode and the superiority of the proposed curve fitting and linear approximation based noise canceling algorithm.