• Title/Summary/Keyword: Mode mismatch

Search Result 67, Processing Time 0.025 seconds

Force-To-Rebalance Mode of a Resonator Gyro and Angular Rate Measurement Tests (공진 자이로의 재평형 모드 구현과 각속도 측정 실험)

  • Jin, Jaehyun;Kim, Dongguk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.563-569
    • /
    • 2014
  • This article focuses on a hemispherical resonator gyro driven by the Coriolis effect. A hemispherical shell, called a resonator, is maintained in the resonance state by amplitude control and phase locking control. Parametric excitation has been used to control the amplitude. For rate measurement mode or FTR mode, nodal points have been kept to an amplitude of zero. Angular rate measurement has been demonstrated by rotating a resonator. Frequency mismatch between two stiffness principal axes is a major cause of low performance: vibrating pattern drift and reduced control effectiveness. This mismatch has been reduced significantly by the addition of small mass. A negative spring effect, which lowers resonance frequencies, has been verified experimentally.

Properties of Ti:$LiNbO_3$ Optical Waveguide by Diffusion in Air Atmosphere and Proposal of a Polishing Method (Air 분위기로 제작한 Ti:$LiNbO_3$ 도파로 특성 및 폴리싱 방법제안)

  • 김성구;윤형도;윤대원;한상필;박계춘;유용택
    • Electrical & Electronic Materials
    • /
    • v.10 no.7
    • /
    • pp.682-691
    • /
    • 1997
  • We have investigated the guided optical properties of a Ti:LiNbO$_3$optical waveguide which was fabricated by Ti-diffusion in an air atmosphere and proposed an effective polishing method of waveguide endfaces. And the results of guided optical mode and fabrication condition were obtained as follows; \circled1 propagation loss : 0.53 dB/cm \circled2 mode size : horizontal/vertical=12.5${\mu}{\textrm}{m}$ \circled3 mode mismatch : 1.7 dB \circled4 diffusion temperature : 105$0^{\circ}C$, time : 8 hours \circled5 atmosphere : air

  • PDF

Effects on Logging-While-Drilling (LWD) data of mismatch between multipole sources (다극자 송신원들 사이의 불일치가 LWD 자료에 미치는 영향)

  • Byun, Joong-Moo;Joo, Yong-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.143-153
    • /
    • 2009
  • Using a discrete wavenumber method, we examine the effects on Logging-While-Drilling (LWD) logs when a mismatch exists between the amplitudes or generating times of the signals from individual monopoles in a LWD multipole source. An amplitude-mismatched LWD dipole/quadrupole source produces non-dipole/non-quadrupole modes as well as flexural and screw modes. The strongest of non-dipole/non-quadrupole modes is the Stoneley mode, whose amplitude increases with increasing mismatch. However, we can recover the flexural mode signals by A-C processing, and the screw mode by A-B+C-D processing, respectively. The Stoneley mode, which has the same amplitude at the same radial distance from the borehole axis, is cancelled out by A-C and A-B+C-D processing as long as the tool is placed at the centre of the borehole. The responses from a time-mismatched LWD multipole source look like the summation of responses by two or four monopole sources off the borehole axis. However, we can avoid the misinterpretation of the formation velocities by referring to the computed dispersion curves, which are independent of the arrival times of the modes, on the frequency semblance plot.

A MEIS Study on Ge Eppitaxial Growth on Si(001) with dynamically supplied Atomic Hydrogen

  • Ha, Yong-Ho;Kahng, Se-Jong;Kim, Se-Hun;Kuk, Young;Kim, Hyung-Kyung;Moon, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.156-157
    • /
    • 1998
  • It is a diffcult and challenging pproblem to control the growth of eppitaxial films. Heteroeppitaxy is esppecially idfficult because of the lattice mismatch between sub-strate and depposited layers. This mismatch leads usually to a three dimensional(3D) island growth. But the use of surfactants such as As, Sb, and Bi can be beneficial in obtaining high quality heteroeppitaxial films. In this study medium energy ion scattering sppectroscoppy(MEIS) was used in order to reveal the growth mode of Ge on Si(001) and the strain of depposited film without and with dynamically supplied atomic hydrogen at the growth thempperature of 35$0^{\circ}C$. It was ppossible to control the growth mode from layer-by-layer followed by 3D island to layer-by-layer by controlling the hydrogen flux. In the absent of hydro-gen the film grows in the layer-by-layer mode within the critical thickness(about 3ML) and the 3D island formation is followed(Fig1). The 3D island formation is suppressed by introducing hydrogen resulting in layer-by-layer growth beyond the critical thickness(Fig2) We measured angular shift of blocking dipp in order to obtain the structural information on the thin films. In the ppressence of atomic hydrogen the blocking 야 is shifted toward higher scattering angle about 1。. That means the film is distorted tetragonally and strained therefore(Fig4) In other case the shift of blocking dipp at 3ML is almost same as pprevious case. But above the critical thickness the pposition of blocking dipp is similar to that of Si bulk(Fig3). It means the films is relaxed from the first layer. There is 4.2% lattice mismatch between Ge and Si. That mismatch results in about 2。 shift of blocking dipp. We measured about 1。 shift. This fact could be due to the intermixing of Ge and Si. This expperimental results are consistent with Vegard's law which says that the lattice constant of alloys is linear combination of the lattic constants of the ppure materials.

  • PDF

Phase-Locked Loops using Digital Calibration Technique with counter (카운터 기반 디지털 보상 기법을 이용한 위상 고정 루프)

  • Jeong, Chan-Hui;Abdullah, Ammar;Lee, Kwan-Joo;Kim, Hoon-Ki;Kim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.320-324
    • /
    • 2011
  • A digital technique is adopted to calibrate the current mismatch of the charge pump (CP) in phase-locked loops. A 2 GHz charge pump PLL (CPPLL) is used to justify the proposed calibration technique. The proposed digital calibration technique is implemented simply using a counter. The proposed calibration technique reduces the calibration time by up to a maximum of 50% compared other with techniques. Also by using a dual-mode CP, good current matching characteristics can be achieved to compensate $0.5{\mu}A$ current mismatch in CP. It was designed in a standard $0.13{\mu}m$ CMOS technology. The maximum calibration time is $33.6{\mu}s$ and the average power is 18.38mW with 1.5V power supply and effective area is $0.1804mm^2$.

Design and Implementation of a Polar Transmitter (폴라송신기의 설계 및 구현)

  • Kang, Sanggee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.55-59
    • /
    • 2014
  • Multi-band and multi-mode transmitters are needed for SDR and CR. Recently many types of polar transmitters have been studied in order to implement a multi-band and multi-mode transmitter. Polar transmitters have many advantages, such as a simple structure, high efficiency and etc. In this paper we consider the number of D/A bit and the effects of a delay mismatch as design parameters for implementing polar transmitters. From the simulation we know that a 10 bit D/A is sufficient and a delay mismatch must be maintained small than 1/64 chip for satisfying the spectrum mask characteristics. We implement a polar transmitter based on the design parameters and the measured output signal meet the spectrum mask of 800MHz CDMA.

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.

Improved method of lateral offset calculation for optical waveguide (광도파로의 곡률 반경에 따른 모드특성과 Lateral Offset 변화)

  • 박순룡;김우택;라상호;오범환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.408-412
    • /
    • 1998
  • As the radius of curvature of curved optical waveguide gets smaller, the loss increases at the junction of linear-curved waveguide by the cross sectional mode mismatch. The concept of lateral offset has been used widely to minimize it, and simple method of maximum matching has been efficient for most cases of silica waveguide with low optical confinement and large radius of curvature. Here, we analyzed that the propagation mode characteristics of the lateral offset and propagation mode characteristics of general case with effective index method and Airy function solution. As the normalized frequency varies, mode characteristics changes near the boundary of 1/V=0.7 and the simple matching of gaussian profile might give -35% of error at most. We proposed improved method with a new correction factor to improve the mode mismatch problem of conventional methods for general cases, and showed the convenience and feasibility of this method for the calculation of the lateral offset.

  • PDF

Mode-mismatch-robust squeezed light from a self-imaging optical parametric oscillator

  • Roh, Chan;Gwak, Geunhee;Ra, Young-Sik
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.61.1-61.1
    • /
    • 2021
  • Squeezed light는 중력파 검출기의 양자 잡음을 줄여 측정의 민감도를 향상시키기 위해 사용하는 양자 광원이다. Squeezed light는 광학적 손실에 민감하기 때문에 중력파를 측정하기 위해서는 정밀한 mode matching이 필요하다. 하지만 mode mismatching은 실제 실험 상황에서 동적으로, 그리고 무작위로 나타나므로 정밀하게 조정하기 어렵다. Mode mismatching에 견고한 squeezed light를 만들기 위해서는 multimode squeezed light가 필요하다. Multimode squeezed light를 만드는 방법으로 는 self-imaging cavity를 이용하여 생성하는 방법이 대표적으로 알려져 있다. 이 발표에서는 self-imaging cavity 기반으로 만든 optical parametric oscillator(OPO) 에서 생성된 squeezed light가 기존 OPO로 생성한 squeezed light 보다 여러 spatial mode mismatching (위치, 방향, 크기 빗맞음)에 대해 견고함을 소개한다.

  • PDF

Welded plate and T-stub tests and implications on structural behavior of moment frame connections

  • Dong, P.;Kilinski, T.
    • Steel and Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.35-50
    • /
    • 2002
  • A series of tests on simple-welded plate specimens (SWPS) and T-stub tension specimens simulating some of the joint details in moment frame connections were conducted in this investigation. The effects of weld strength mismatch and weld metal toughness on structural behavior of these specimens were considered under both static and dynamic loading conditions. Finite element analyses were performed by taking into account typical weld residual stress distributions and weld metal strength mismatch conditions to facilitate the interpretation of the test results. The major findings are as follows: (a) Sufficient specimen size requirements are essential in simulating both load transfer and constraint conditions that are relevant to moment frame connections, (b) Weld residual stresses can significantly elevate stress triaxiality in addition to structural constraint effects, both of which can significantly reduce the plastic deformation capacity in moment frame connections, (c) Based on the test results, dynamic loading within a loading rate of 0.02 in/in/sec, as used in this study, premature brittle fractures were not seen, although a significant elevation of the yield strength can be clearly observed. However, brittle fracture features can be clearly identified in T-stub specimens in which severe constraint effects (stress triaxiality) are considered as the primary cause, (d) Based on both the test and FEA results, T-stub specimens provide a reasonable representation of the joint conditions in moment frame connections in simulating both complex load transfer mode and constraint conditions.