• 제목/요약/키워드: Mode Size

검색결과 1,737건 처리시간 0.032초

Down Regulation of miR-34a and miR-143 May Indirectly Inhibit p53 in Oral Squamous Cell Carcinoma: a Pilot Study

  • Manikandan, Mayakannan;Rao, Arunagiri Kuha Deva Magendhra;Arunkumar, Ganesan;Rajkumar, Kottayasamy Seenivasagam;Rajaraman, Ramamurthy;Munirajan, Arasambattu Kannan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7619-7625
    • /
    • 2015
  • Background: Aberrant microRNA expression has been associated with the pathogenesis of a variety of human malignancies including oral squamous cell carcinoma (SCC). In this study, we examined primary oral SCCs for the expression of 6 candidate miRNAs, of which five (miR-34a, miR-143, miR-373, miR-380-5p, and miR-504) regulate the tumor suppressor TP53 and one (miR-99a) is involved in AKT/mTOR signaling. Materials and Methods: Tumor tissues (punch biopsies) were collected from 52 oral cancer patients and as a control, 8 independent adjacent normal tissue samples were also obtained. After RNA isolation, we assessed the mature miRNA levels of the 6 selected candidates against RNU44 and RNU48 as endogenous controls, using specific TaqMan miRNA assays. Results: miR-34a, miR-99a, miR-143 and miR-380-5p were significantly down-regulated in tumors compared to controls. Moreover, high levels of miR-34a were associated with alcohol consumption while those of miR-99a and miR-143 were associated with advanced tumor size. No significant difference was observed in the levels of miR-504 between the tumors and controls whereas miR-373 was below the detection level in all but two tumor samples. Conclusions: Low levels of miR-380-5p and miR-504 that directly target the 3'UTR of TP53 suggest that p53 may not be repressed by these two miRNAs in OSCC. On the other hand, low levels of miR-34a or miR-143 may relieve MDM4 and SIRT1 or MDM2 respectively, which will sequester p53 indicating an indirect mode of p53 suppression in oral tumors.

미세조직이 Sn계 무연솔더의 크리프 특성에 미치는 영향 (Effects of Microstructure on the Creep Properties of the Lead-free Sn-based Solders)

  • 유진;이규오;주대권
    • 마이크로전자및패키징학회지
    • /
    • 제10권3호
    • /
    • pp.29-35
    • /
    • 2003
  • SnAg, SnAgCu, SnCu 무연솔더합금을 주조 상태에서 냉간압연한 후 열적으로 안정화한 시편 (TS)과, 실제 솔더 범프와 유사한 미세구조의 수냉에 급속 냉각(WQ)된 시편 두가지를 $100^{\circ}C$에서 크리프 실험을 행하였다. 급속냉각한 시편의 냉각속도는 140-150 K/sec로 primary $\beta-Sn$ 크기가 TS 시편보다 5∼10배 정도 작았으며, 기지내 primary $\beta-Sn$이 차지하는 분율은 증가하였다. 반면에 공정상 내의 $Ag_3Sn$상의 크기는 더 작아졌다. 크리프 실험 결과 WQ 시편의 최소크리프 변형율 속도($\{beta}_{min}$)가 TS 보다 약 $10^2$배 정도 작았으며. 더 큰 파괴시간을 보였다. TS-SnAg의 크리프파괴는 $Ag_3Sn$ 또는 $Cu_6Sn_5$에서의 공공의 핵생성, power-law 크리프에 의한 공공의 성장, 그리고 크리프 공공의 상호 연결로 일어났으며, WQ-SnAgCu는 시편이 두께가 얇아 네킹에 의해 파괴가 일어났다.

  • PDF

디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화 (Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography)

  • 권순무;김부순;박형준;강영한
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.535-540
    • /
    • 2015
  • X선 조사야(X-ray beam field)는 X선관 앞에 부착된 선속제한기구(beam limiting device)인 조리개(collimator)에 의해 조절된다. 조리개는 1차 X선을 조절하여 환자의 피폭선량을 감소시키고 산란선량을 감소시켜 영상의 화질을 향상시키는 중요한 기능을 한다. 그러나 유방촬영장치의 조리개에 대해서 따로 규정되어 있지 않으며 상업화된 장치에서는 조사야가 사각형으로 조절되는 조리개를 사용하고 있다. 최근 디지털 유방촬영장치의 보급이 확대되고 있으나 film/screen방식에서부터 적용되던 사각형으로 조사야가 조절되는 조리개가 사용되고 있다. 따라서 본 연구에서는 디지털 유방촬영에서 조사야 조절 사용에 대한 실태조사 후 유방의 크기와 모양에 따라 조사야를 조절할 수 있는 다엽조리개를 제작 후 적용했을 때 영상의 화질변화와 평균유선선량, 면적선량 값의 변화를 알아보았다. 사각형으로 조사야가 조절되는 조리개와 비교하여 다엽 조리개를 적용한 영상에서 통계적으로 유의한 차이가 없었으며 DAP값 또한 50.72% 감소되었다. 따라서 디지털 유방촬영장치에서 조사야를 최적화하기 위한 자동조사야조절장치 개발이 환자 피폭선량 감소에 도움이 될 것으로 판단된다.

가진 각도에 따른 야구배트의 공진주파수 분석 (Resonance Frequency Analysis of A Baseball Bat by Impact Angle)

  • 박선향;정우양;정환희;이상준
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.777-783
    • /
    • 2015
  • 이방성 물질인 목재는 방향별로 나타나는 세포종류, 크기, 배열에 따라 경도, 성질, 치수변화등 서로 다른 성질을 나타낸다. 또한 사용용도에 따라 다양한 형태로 이용할 수 있는 재료이다. 그러나 동일수종의 목재 내에서도 변이성이 나타나기 때문에 각각의 고유성질과 용도에 대해 정확히 파악하고 이론 및 기술 등의 정립을 통해 재료 이용의 극대화를 위한 연구가 필요하다. 목재의 물리적 특성 및 밀도와 탄성계수의 관계에 관한 연구는 국내외로 다양하게 이루어져 왔으나 대부분 규격화된 시편으로 얻은 값을 통해 상관관계를 분석해왔으며 목재 완제품에 적용한 연구가 거의 없는 실정이다. 또한 야구배트에 대한 진동거동 및 타격에 관한 논문은 많이 있으나 목재 배트를 재료로서 물성을 분석한 연구가 미비한 실정이므로 이와 관련된 연구가 필요하다. 본 연구에서는 캐나다산 경단풍나무로 제작한 배트의 실제완제품을 이용하여 소재물성을 파악하고 주파수 비교를 통해 탄성계수를 분석하고자 한다. 소재물성 비교를 위해 배트의 연륜분포와 밀도 등 기초물성을 조사하였고 공진주파수와 관계식(ASTM C1259)을 통해 탄성계수를 산출하여 재료의 반발력을 산출하였다. 공진주파수 증가에 따른 연륜분포 비교에서 감소하는 경향을 나타냈다. 섬유방향에 따른 가진 각도별 비교에서 섬유방향과 수직한 $0^{\circ}$ 방향으로 가진할 때보다 수평한 $90^{\circ}$ 방향으로 가진할 때 탄성계수 값이 높게 나타났다.

제주도 연안 정치망 조업시스템 개발에 관한 연구 3. 구조개량을 위한 각멍어구 모형실험 (Studies on the Development of the Fishing System of Set Net in the Coast of Jeju Island 3. The Mode| Experiment of Fyke Net for Construction Improvement)

  • 김석종;구명성
    • 수산해양기술연구
    • /
    • 제40권1호
    • /
    • pp.37-46
    • /
    • 2004
  • 제주도 연안 정치망 조업 시스템 개량과 개발분야에서 연안해역에서 널리 사용되고 있는 각망어구의 구조개량을 위한 기초연구로서 현재 사용되고 있는 실물망을 1/20로 축소하여 개량된 입구 구조를 갖춘 모형 어구 8종류를 제작하고, 실험 수조에서 고등어 어군을 이용하여 모형 어구에 대한 어군의 입 ${\cdot}$ 출망 행동을 관찰 분석하였는데, 그 결과는 다음과 같다. 1. 원통그물내에서의 어군의 행동 패턴은 원형 모양으로 한쪽 원통그물내에 체류하는 행동과 긴 타원형 모양으로 좌 ${\cdot}$ 우 원통그물내를 왕복 유영하는 행동패턴으로 분류할 수 있었다. 2. 모형 어구 내에서의 고등어 어군의 평균 유영 속도는 원통 그물 중간 부분에서 24.9cm/sec, 오른쪽 원통그물내에서 12.6cm/sec, 입구에서 32.0cm/sec였다. 3. 어군의 입망율은 경과 시간 60초일 때 표준 모형 어구에서는 47%였고, 깔대기 그물이 길이가 35cm 의 모형 어구에서는 40%로 나타났는데, 양자의 차이는 7% 정도로 그다지 크지 않았다. 4. 어군의 출망율은 경과 시간 60초일 때 표준 모형 어구에서는 69%였고, 깔대기 그물의 길이가 35cm 의 모형 어구에서는 10%로 나타났는데, 양자의 차이는 59% 정도로 그 폭이 컸다. 5. 어군의 잔여율은 경과 시간 60초일 때 표준 모형 어구에서는 31%였고, 깔대기 그물의 길이가 35cm의 모형 어구에서는 90%로 나타났는데, 양자의 차이는 59% 정도였다.

Ag 페이스트를 소스와 드레인 전극으로 사용한 OTFT-OLED 어레이 제작 (The Fabrication of OTFT-OLED Array Using Ag-paste for Source and Drain Electrode)

  • 류기성;김영배;송정근
    • 대한전자공학회논문지SD
    • /
    • 제45권5호
    • /
    • pp.12-18
    • /
    • 2008
  • 본 연구는 PC(polycarbonate) 기판 위에 소스(source)/드레인(drain) 전극으로 Ag 페이스트를 스크린 인쇄하여 OTFT(organic thin film transistor)를 제작하였다. 또한 이렇게 제작된 OTFT를 적용하여 OTFT-OLED(organic light emitting diode) 어레이를 제작하였으며 OTFT의 소스 및 드레인 전극과 더불어 데이터 배선전극을 Ag 페이스트를 이용하여 형성하였다. Ag 페이스트는 스크린 마스크의 mesh에 따라 325 mesh용과 500 mesh용을 사용하였으며, 325 mesh용 페이스트는 선폭 60 ${\mu}m$, 500 mesh용 페이스트는 선폭 40 ${\mu}m$까지 인쇄가 가능하였다. 그리고 면저항은 각각 $60m{\Omega}/\square,\;133.1m{\Omega}/\square$이었다. 제작된 OTFT의 성능은 이동도가 자각 0.35 $cm^2/V{\cdot}sec$와 0.12 $cm^2/V{\cdot}sec$, 문턱전압 -4.7 V와 0.9 V이었으며, 전류 점멸비는 ${\sim}10^5$이었다. OTFT-OLED 어레이는 인쇄성이 우수한 500 mesh용 Ag 페이스트를 사용하였으며 OTFT의 채널길이를 50 ${\mu}m$로 설계하여 제작하였다. OTFT-OLED 어레이의 화소는 2개의 OTFT, 1개의 캐패시터 그리고 1개의 OLED로 구성하였고, 크기는 $2mm{\times}2mm$이며, 해상도는 $16{\times}16$ 이다. 제작된 어레이는 일부 불량 화소를 포함하고 있지만 능동형 모드로 동작함을 확인할 수 있었다.

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

소규모 지하공동 3차원 형상 특성을 반영한 수치해석에 관한 연구 (A numerical study on the 3-Dimensional shape characteristics of small underground cavities)

  • 안준상;강경남;송기일;김우석;김병찬
    • 한국터널지하공간학회 논문집
    • /
    • 제20권5호
    • /
    • pp.787-807
    • /
    • 2018
  • 한국에서 시행중인 특별법에 의한 지하안전영향 평가 수행 시, 필수적으로 지하공동의 발생 유무를 조사하여야 한다. 지하공동 발견 시에는 수치해석을 통해서 지하안전성을 평가하도록 규정하였다. 선행 연구를 통해서 소규모 지하공동의 2차원 형상변화를 통한 안전율 기반의 안정성 평가 가능성을 제시하였다. 본 연구에서는 3차원 형상을 고려하여 소규모 지하공동의 영향을 연속체 해석 프로그램을 사용해서 검토하였고, 선행 연구에서 제시한 2차원 해석결과와 비교하였다. 지하공동의 3차원 형상이 구(sphere)형에 가깝게 발견되면, 공동의 크기, 위치 등에 관계없이 전단강도감소기법으로 안전율을 산정하여 평가하는 방법에 무리가 없을 것으로 판단된다. 지표면으로부터의 깊이 2 m 이상, 장축과 단축의 비(a/b)가 2.0 이상인 장대형 지하공동이 연직방향으로 서있는 형상이라면, 전단강도감소기법을 사용한 안정성 평가에 안전율 이외에 파괴양상 파악에도 주의가 필요할 것으로 판단된다. 본 연구의 결과는 지하안전영향평가에 관한 기초 자료가 될 수 있을 것으로 판단된다.

복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구 (Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom)

  • 김기원;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.407-414
    • /
    • 2016
  • 본 연구의 목적은 엑스선 선원과 검출기사이의 거리(SID)변화와 부가필터 사용 유무에 따른 피폭선량을 측정하여 환자선량을 최소화 하는 것이다. 연구를 위해 사용한 기기 및 팬텀은 DR시스템, 복부 조직 등가팬텀 그리고 알루미늄 필터를 사용하였다. 촬영 조건으로는 관전압을 80 kVp로 고정하고, 선량은 자동노출제어 장치를 통해 설정 하였다. 또한, 조사야는 $16{\times}16inch$를 사용하였다. 실험방법으로는 SID를 100 cm, 110 cm, 120 cm, 130 cm로 변화를 주어 각각 10회 측정하였고, 조사야 중심에 Piranha657 선량계를 위치시켰다. 촬영된 영상은 이미지J 통해 분석하였다. 실험 결과는 관전류량은 SID가 증가함에 따라 증가한 반면, 입사표면선량(ESD)은 SID가 증가함에 따라 급격히 감소하였다. 이는 낮은 에너지를 갖는 X선 광자들이 여과판사용으로 인해 제거되어 ESD의 감소로 기인한 것으로 사료되며, 이미지 J를 통한영상의 히스토그램 분석결과 SID 변화에 따라 ESD와 조사조건의 차이가 나타나지만 영상의 히스토그램상의 분포는 큰 차이는 없었다. 따라서, SID를 크게 할수록 환자의 선량을 줄일 수 있으며, 아울러 소아 등을 촬영할 때, 부가필터를 사용하면 환자선량을 더욱 줄일 수 있을 것이라 사료된다.

Process Development for Effective Denitrification by Biofilter Using Loess Ball

  • CHOI DU BOK;LEE DONG BYUNG;CHA WOL SUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.412-420
    • /
    • 2005
  • In order to investigate factors affecting the denitrification in the F-STEP PROCESS using a loess ball as support media and Pseudomonas DWC 17-8, calcining temperature, loess ball size, pH, nitrate concentration, working temperature, and inhibitor were studied in batch mode using synthetic sludge. A 5- 10 mm of loess ball (960$^{circ}$ of calcining temperature) was the most suitable for denitrification. When the initial pH was increased from 3.0 to 7.0, the removal efficiency of nitrate was increased. Specifically, at initial pH of 7.0, the maximum removal efficiency of nitrate was 5.0 mg/min. When the initial concentration of nitrate was increased from 100 to 400 mg/l, the removal efficiency of nitrate was proportional to the concentration of nitrate. The maximum removal efficiency of nitrate was 5.72 mg/min at 400 mg/l of initial concentration. When the operating temperature was increased from 10 to 30$^{circ}$, the removal efficiency of nitrate was increased from 0.76 to 6.15 mg/min, and at above 40$^{circ}$ of operating temperature, it was decreased from 4.0 to 2.0 mg/min. Among the various inhibitors, higher than 10$^{-1}$ M of sodium azide abolished this reaction completely. When the KCN concentration was above 10$^{-1}$ M, the reaction was inhibited completely. In the case of 2,4-dinitrophenol and sodium sulphide, it was inhibited at above 10$^{-2}$ M completely. For testing the various flow orders of the F-STEP PROCESS for effective denitrification using practical wastewater, continuous experiments under the optimum conditions were carried out for 60 days. Among the various processes, the PROCESS A gave the highest efficiencies of denitrification, nitrification, and total nitrogen (TN) removal with 86.5, 89.5, and $90\%$, respectively. For scale-up in the PROCESS A, real farm wastewater was used and pilot tests carried out for 90 days. The denitrification efficiency was $97.5\%$, which was increased by $12.7\%$. The efficiencies of TN removal and nitrification were 96.6 and $70.0\%$, respectively. The removal efficiency of chemical oxygen demand (COD) was $63.7\%$, which was increased by $20\%$.