• Title/Summary/Keyword: Mock-up 실험

Search Result 228, Processing Time 0.03 seconds

Mock-up Test of Concrete Using AE Water Reducing Agent of Early-Strength Type in Construction Field (조기강도발현형 AE감수제를 사용한 콘크리트의 현장 Mock-up 실험)

  • 황인성;김기훈;김규동;이승훈;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.1-4
    • /
    • 2004
  • In this paper. applicability of high early strength type AE water reducing agent(HESAEWA) developed by the authors is discussed by applying Mock-up test. For fresh concrete properties, concrete using existing AE water reducing agent(EAEWRA) and HESAEW A meets the target slump and air content at jobsite. Setting time of concrete using HESAEWA is shorter than that using EAEWRA. Remarkable variance of bleeding and settlement is not observed with type of AE water reducing agent. For hardened concrete properties, use of HESAEW A results in higher strength development compared with that of EAEWRA at standard curing and in field curing condition. Reaching time to accomplish 5MPa of compressive strength. which is possible to remove side form. is taken using HESAEWA earlier than that of EAEWRA by 1day. Therefore, it is confirmed that use of HESAEWA can meet the requirements of general quality of concrete and achieve high early strength development as well as has a desirable field applicability.

  • PDF

Development and Performance Evaluation of a Sloped Lightshelf Daylighting System (Mock-up model을 이용한 경사형광선반 채광시스템의 개발 및 채광성능평가에 관한 연구)

  • Kim, Jeong-Tai;Kim, Ki-Cheol;Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.39-50
    • /
    • 2004
  • One of the challenge for successful daylighting design might be to capture sunlighting that varies in both intensity and position and to deliver the luminous flux into the inner space as deep as possible. Conventional glazing apertures allow daylight in the outer 3.5m of a perimeter spaces. More advanced daylighting technologies can extend this daylighting depth by reflecting sunlight further from the windows within a deep floor area. For this purpose, this study developed light shelves based on performance evaluation with a mock-up model that constructed recently and measured under real sky condition. All these daylighting devices have a customized geometry developed from the solar path at a given latitude and utilize unique reflecting finishing to maximize the amount of redirection and diffusion of the daylight. This paper tells that the best daylighting penetration typically can be expected from using light-colored sloped external shelves.

Field Mock up Test of High Strength Concrete for Busan Lotte Town (부산롯데타운용 고강도 콘크리트 현장 적용을 위한 Mock-up Test)

  • Moon, Hyung-Jae;Park, Soon-Jeon;Heo, Jin-Wook;Koo, Ja-Sul;Jeong, Youn-Sung;Lee, Yang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.223-224
    • /
    • 2009
  • This study was performed to development 80MPa high strength concrete using local raw material of Busan and to estimate field application ability. As the result of three types of mixture, fresh and hardened properties were satisfied with target requirement properties. Hydration temperature was revealed mean 75$\sim$85$\circ$C. Additionally, in case of compressive strength, core specimen's strength is six times higher than field curing specimen by very high hydration heat.

  • PDF

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED (광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증)

  • Cha, Kwang-Seok;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

Experimental Study of Floor Impact Sound Insulation by the Finishing Materials and Porous Ratio of Insulations of Floor Structure in Mock-up Test Room (모형실험실에서 바닥충격음 완충재의 발포율 및 바닥마감재의 변화에 따른 충격음 차단성능에 대한 실험적 연구)

  • 김태희;오진균;신일섭;조창근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.756-759
    • /
    • 2003
  • It is increasing the interest on the comfortable dwelling environment and the efforts to solve the problem of the floor impact noise in apartment houses have been realized, as a result numerous products have been made. The purpose of this study is to investigate the sound insulation performances according to foaming rate of floor impact noise insulators and flooring coverings in Mock-up Test Room. The test results of impact insulation performance for each floor impact noise insulators is that double structure of insulator is excel than one in low-middle frequency band and as foaming rate go up, the sound insulation performance is improved.

  • PDF

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

Mock-up Test for Field Application of a Polylon Fiber Method (폴리론 화이버 공법의 현장적용을 위한 Mock-up Test)

  • Kwon, Hae-Won;Son, Ho-Jung;Jee, Suk-Won;Lee, Byeong-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.405-408
    • /
    • 2008
  • This study, as mock-up test for applying Polylon Fiber engineering method to the field, analyzed the fundamental characteristics and the fireproof characteristics of high strength concrete mixed with Polylon Fiber 0.05% and the results are summarized as followings. From the characteristic of the fresh concrete, both slump flow and air content were appeared to satisfy target range. And from the characteristic of hardened concrete, all compressive strengths according to the curing conditions were appeared to satisfy design standard strength of 60 MPa. From the fireproof characteristic, small scaling and spalling phenomenon were partially appeared on the surface part of specimens, but generally the excellent fireproof capacities were appeared. From the characteristic of temperature hysteresis, the highest temperature and the average temperature of reinforcing part after fire-resistant test for 3 hours were $531^{\circ}C$ and $405{\circ}C$, respectively and then satisfied fireproof standard of the Ministry of Land Transportation and Maritime Affairs.

  • PDF