• 제목/요약/키워드: Mix Proportion

검색결과 354건 처리시간 0.021초

옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험 (Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top)

  • 서유현;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

폴리프로필렌 섬유 혼입 모르타르의 내화성능 평가 (Evaluation of Fire-Resistant Performance for Polypropylene Fiber-Mixed Mortar)

  • 이찬영;심재원;안태송;임채혁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.473-476
    • /
    • 2006
  • In this study, evaluation of fire-resistant performance for polypropylene fiber-mixed mortar was performed to establish specification for stability of tunnel structure against fire afterward. In the fire-resistant performance test with mix proportion of polypropylene fiber, cracks were observed for mortar under 0.15% of fiber content, but micro-cracks were remarkably reduced for mortar more than 0.2% of fiber content. From the results, we are concluded that optimal mix proportion of polypropylene fiber is $0.20{\sim}0.25%$.

  • PDF

시간가열온도곡선에 따른 터널라이닝 콘크리트의 내화성능 평가 (Evaluation of Fire-Resistant Performance for Tunnel Lining Concrete with Heating Temperature-Time Curves)

  • 이찬영;심재원;안태송;임채혁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.477-480
    • /
    • 2006
  • In this study, evaluation of fire-resistant performance for polypropylene fiber-mixed mortar was performed to establish specification for stability of tunnel structure against fire afterward. In the fire-resistant performance test with mix proportion of polypropylene fiber, cracks were observed for mortar under 0.15% of fiber content, but micro-cracks were remarkably reduced for mortar more than 0.2% of fiber content. From the results, we are concluded that optimal mix proportion of polypropylene fiber is $0.20{\sim}0.25%$.

  • PDF

인천 LNG 지하탱크 #219 Bottom Slab시공 및 온도균열 안정성 평가 (Construction and Evaluation of Thermal Crack Stability about Bottom Slab of the #219 LNG Underground Tank in Incheon)

  • 손영준;하재담;엄태선;이종열;박종식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.689-692
    • /
    • 2006
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the temperature crack of massive concrete, the selection of appropriate materials like low heat cement, mixture materials, etc. is essential. In tills study, mix proportion using low heat portland cement and lime stone powder was designed and the best mix proportion, B-1, was selected. When bottom slab of the #219 LNG tank in Incheon was constructed, concrete temperature was measured. And thermal stress was analyzed about bottom slab of the LNG tank. As results of the thermal analysis, crack index was 1.60 in bottom slab and satisfied with construction specifications(over 1.0).

  • PDF

유효 영역 판별 모델에 따른 데이터베이스 기반 콘크리트 최적 배합 선정 (Optimum Concrete Mix-proportion based on Database according to Assessment Model for Effective Region)

  • 이방연;김재홍;김진근;이성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.909-912
    • /
    • 2006
  • This paper examined the applicability of convex hull, which is defined as the minimal convex polygon including all points, to assessment model for effective region. In order to validate the applicability of the convex hull to assessment model for effective region, a genetic algorithm was adopted as a optimum technique, and an artificial neural network was adopted as a prediction model for material properties. The mix-proportion obtained from the proposed technique is more reasonable than that obtained from previous work.

  • PDF

국내 레미콘의 권역별 배합특성에 관한 분석 - 경기 및 경상권역을 중심으로 - (Analysis of the Mixing Conditions by Domestic Ready-Mixed Concrete Rage Sphere)

  • 서휘완;김영일;강창운;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.131-132
    • /
    • 2011
  • This study analyzes the yearly-best delivered size range of truck mixer based on the specified mix, Water to Binder Ratio, aggregate proportion and unit amount with statistical method targeting on Kyeongi and Kyeongsang province and compares with the similar materials of Japan to propose as a basic standard for the quality control of mixer truck. As a result, in case of the Water to Binder Ratio of these areas, it is higher than Japan's due to the excessive safety rate reflecting the changes of differential value impact and unit amount, and the unit amount's standard deviation is very large by reflecting the changes of the amount used and chemical admixture susceptibility. In case of aggregate proportion, the frequency rate is about 50%, which is very similar value with Japan's one.

  • PDF

The non-shrinkage grout to use ground fly ash as admixture

  • Kim, Yoo;Chu, Yong-Sik;Seo, Sung-Kwan;Kim, Jang-ho Jay
    • Journal of Ceramic Processing Research
    • /
    • 제19권6호
    • /
    • pp.509-513
    • /
    • 2018
  • This study uses fly ash for non-shrinkage grout in order to develop strength of grout and improve its durability. We grind fly ash to the extent of $7,000cm^2/g$ and use ground fly ash and raw fly ash respectively at the proportion of 10%, 20%, 30% instead of OPC and compare the results drawn on the condition of each proportion. As a mixed material of grout, EVA and water-reducing agent is added in order to prevent bleeding and improve segregation resistance, CSA is added with a view to preventing drying shrinkage and improving early strength property. In regard to flow and flow time test for analyzing and evaluating workability, it is revealed that grouts of all mix proportions except raw fly ash 30% mix proportion satisfy all performance criteria. With regard to length change rate, grout with no admixture shows the highest shrinkage rate, but the rate is 0.0005%, extremely insignificant rate. As material age increases, compressive strength of two grouts, that is to say ground fly ash 10% and 20%-used grouts, exceed that of grout with no admixture or show high-level compressive strength.

진동제어 콘크리트 개발에 관한 실험적 연구 (Experimental Study on the Development of Vibration Controlled Concrete)

  • 최우성;이대형;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.180-185
    • /
    • 1996
  • Construction activities and operation of transportation facilities have caused unfavorable effects such as civil petitions associated with vibration-induced damages or nuisances. The objedtive of this research is to develop vibration-controlled concrete containing foams, latex, rubber powders, plastic resins and etc as a concrete mixture. As the first step to achieve this research, preliminary mix designs have been carried out to find out an appropriate mix proportion above 200kg/㎠ in uniaxial compressive strength, and investigate their dynamic mechanical characteristics such as dynamic elastic moduli, material damping ratio, Poisson's ratio, resonant frequency and etc.

  • PDF

최소 볼록 집합을 이용한 데이터베이스 기반 콘크리트 최적 배합 (Concrete Optimum Mixture Proportioning Based on a Database Using Convex Hulls)

  • 이방연;김재홍;김진근
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.627-634
    • /
    • 2008
  • 이 연구에서는 한정된 데이터베이스를 바탕으로 콘크리트 물성 예측 모델을 만들어 최적 배합을 구할 때, 탐색 범위를 한정된 데이터베이스로 제안함으로써 보다 신뢰성 있는 콘크리트 배합을 제시할 수 있는 기법을 제안하였다. 제안한 기법은 각 구성 재료의 가능한 모든 영역을 포함하는 데이터베이스를 구축하지 않고 최적화 과정에서 탐색 범위를 한정된 데이터베이스로 제안함으로써 콘크리트 물성 예측 모델이 신뢰성을 확보할 수 있게 된다. 이 연구에서 이러한 영역을 유효영역으로 정의 하였다. 제안한 기법은 유전자 알고리즘, 인공신경회로망, 그리고 최소 볼록 집합을 이용하여 구현하였으며, 이 방법의 타당성을 검증하기 위하여 주어진 강도 조건을 만족하면서 최저의 가격으로 제조할 수 있는 배합을 찾는 최적화 문제에 적용하였으며 검증 실험을 수행하였다. 실험 결과 데이터베이스의 영역 특성을 반영하는 제안한 기법을 통하여 보다 정확하고 신뢰성 있는 최적 배합을 찾을 수 있음을 확인하였다.