• Title/Summary/Keyword: Mismatch loss

Search Result 102, Processing Time 0.031 seconds

Improvement of Residual Delay Compensation Algorithm of KJJVC (한일상관기의 잔차 지연 보정 알고리즘의 개선)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Oh, Chung-Sik;Jung, Jin-Seung;Chung, Dong-Kyu;Oyama, Tomoaki;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kawakami, Kazuyuki;Ozeki, Kensuke;Onuki, Hirohumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.2
    • /
    • pp.136-146
    • /
    • 2013
  • In this paper, the residual delay compensation algorithm is proposed for FX-type KJJVC. In case of initial version as that design algorithm of KJJVC, the integer calculation and the cos/sin table for the phase compensation coefficient were introduced in order to speed up of calculation. The mismatch between data timing and residual delay phase and also between bit-jump and residual delay phase were found and fixed. In final design of KJJVC residual delay compensation algorithm, the initialization problem on the rotation memory of residual delay compensation was found when the residual delay compensated value was applied to FFT-segment, and this problem is also fixed by modifying the FPGA code. Using the proposed residual delay compensation algorithm, the band shape of cross power spectrum becomes flat, which means there is no significant loss over the whole bandwidth. To verify the effectiveness of proposed residual delay compensation algorithm, we conducted the correlation experiments for real observation data using the simulator and KJJVC. We confirmed that the designed residual delay compensation algorithm is well applied in KJJVC, and the signal to noise ratio increases by about 8%.

13.56 MHz Wireless Power Transfer System Using Loop Antennas with Tunable Impedance Matching Circuit (가변 임피던스 정합 회로를 갖는 루프 안테나를 이용한 13.56 MHz 무선 전력 전송 시스템)

  • Won, Do-Hyun;Kim, Hee-Seung;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.519-527
    • /
    • 2010
  • In this paper, we proposed a 13.56 MHz wireless power transfer system using loop antennas with tunable impedance matching circuits. In general, a wireless power transfer system shows an impedance mismatching due to a reflected impedance, because a coupling coefficient is varied with respect to separation distance between two resonating antennas. The proposed system can compensate the effect of this impedance mismatch owing to tunable impedance matching circuits using varactor diodes. Therefore, transmission efficiency is enhanced, moreover, the center frequency of the system is not changed, regardless of separation distance between two antennas. In order to demonstrate the performance of the proposed system, a wireless power transfer system with tunable impedance matching circuits is designed and implemented, which has a pair of loop antennas with a dimension of $30\;cm{\times}30\;cm$ cm. The input return loss, coupling coefficient, efficiency, and input impedance variation with respect to a distance between loop antennas were measured. From measured results, the proposed system shows enhanced performances than the case of the general fixed $50\;{\Omega}$ impedance matching circuits. Therefore, we verified that the proposed wireless power transfer system using the proposed impedance matching scheme will be able to ensure robust operation even when the separation distance of antennas is varied.

MICROSATELLITE INSTABILITY AND p53 GENE MUTATION IN ORAL SQUAMOUS CELL CARCINOMA (구강편평상피세포암 조직에서의 Microsatellite 불안정성 및 p53 유전자 돌연변이 분석)

  • Choi, Tae-Ho;Chung, Woon-Bok;Hong, Su-Hyung;Kim, Jin-A;Na, Sun-Oung;Jang, Hyun-Jung;Sohn, Yoon-Kyung;Kim, Chin-Soo;Kim, Jung-Wan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Germ-line mutations at DNA repair loci confer susceptibility to colon cancer in hereditary non-polypopsis colorectal cancer. Somatic loss of DNA mismatch repair gene has been reported in a large variety of other tumor types. Replication errors(RERs) judged by microsatellite instability(MSI) and its associated mutations have been recognized as an important mechanism in various tumor types. To investigate associations between MSI and oral squamous cell carcinoma, the frequency of MSI using 12 microsatellite markers were analyzed for the series of oral tumors. Of 17 tumors, 8 cases(47%) did not show instability at any of the 12 loci; 5(29%) showed instability at $2{\sim}3$ loci; and 4(24%) showed instability above 4 loci. The 4 cases showing widespread MSI did not differ from those without evidence of instability in terms of age at diagnosis, degree of differentiation, metastasis to lymph node, tumor location or the presence of mutations in the p53 tumor suppressor gene. DCC and D17S 796 were the most frequently detected in MSI analysis. There were no correlation between smoking and MSI frequency, instead, smoking was suggested to increase the mutation rate of p53 and development of oral carcinomas.

  • PDF

Selective B Slice Skip Decoding for Complexity Scalable H.264/AVC Video Decoder (H.264/AVC 복호화기의 복잡도 감소를 위한 선택적 B 슬라이스 복호화 스킵 방법)

  • Lee, Ho-Young;Kim, Jae-Hwan;Jeon, Byeung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.79-89
    • /
    • 2011
  • Recent development of embedded processors makes it possible to play back video contents in real-time on portable devices. Because of their limited battery capacity and low computational performance, however, portable devices still have significant problems in real-time decoding of high quality or high resolution compressed video. Although previous approaches are successful in achieving complexity-scalable decoder by controlling computational complexity of decoding elements, they cause significant objective quality loss coming from mismatch between encoder and decoder. In this paper, we propose a selective B slice skip-decoding method to implement a low complexity video decoder. The proposed method performs selective skip decoding process of B slice which satisfies the proposed conditions. The skipped slices are reconstructed by simple reconstruction method utilizing adjacent reconstructed pictures. Experimental result shows that proposed method not only reduces computational complexity but also maintains subjective visual quality.

Three-Dimensional Approaches in Histopathological Tissue Clearing System (조직투명화 기술을 통한 3차원적 접근)

  • Lee, Tae Bok;Lee, Jaewang;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • Three-dimensional microscopic approaches in histopathology display multiplex properties that present puzzling questions for specimens as related to their comprehensive volumetric information. This information includes spatial distribution of molecules, three-dimensional co-localization, structural formation and whole data set that cannot be determined by two-dimensional section slides due to the inevitable loss of spatial information. Advancement of optical instruments such as two-photon microscopy and high performance objectives with motorized correction collars have narrowed the gap between optical theories and the actual reality of deep tissue imaging. However, the benefits gained by a prolonged working distance, two-photon laser and optimized beam alignment are inevitably diminished because of the light scattering phenomenon that is deeply related to the refractive index mismatch between each cellular component and the surrounding medium. From the first approaches with simple crude refractive index matching techniques to the recent cutting-edge integrated tissue clearing methods, an achievement of transparency without morphological denaturation and eradication of natural and fixation-induced nonspecific autofluorescence out of real signal are key factors to determine the perfection of tissue clearing and the immunofluorescent staining for high contrast images. When performing integrated laboratory workflow of tissue for processing frozen and formalin-fixed tissues, clear lipid-exchanged acrylamide-hybridized rigid imaging/immunostaining/in situ hybridization-compatible tissue hydrogel (CLARITY), an equipment-based tissue clearing method, is compatible with routine procedures in a histopathology laboratory.

Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode (홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성)

  • Shin, Woo-Gyun;Go, Seok-Hwan;Ju, Young-Chul;Song, Hyung-Jun;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

REDUCING LATENCY IN SMART MANUFACTURING SERVICE SYSTEM USING EDGE COMPUTING

  • Vimal, S.;Jesuva, Arockiadoss S;Bharathiraja, S;Guru, S;Jackins, V.
    • Journal of Platform Technology
    • /
    • v.9 no.1
    • /
    • pp.15-22
    • /
    • 2021
  • In a smart manufacturing environment, more and more devices are connected to the Internet so that a large volume of data can be obtained during all phases of the product life cycle. The large-scale industries, companies and organizations that have more operational units scattered among the various geographical locations face a huge resource consumption because of their unorganized structure of sharing resources among themselves that directly affects the supply chain of the corresponding concerns. Cloud-based smart manufacturing paradigm facilitates a new variety of applications and services to analyze a large volume of data and enable large-scale manufacturing collaboration. The manufacturing units include machinery that may be situated in different geological areas and process instances that are executed from different machinery data should be constantly managed by the super admin to coordinate the manufacturing process in the large-scale industries these environments make the manufacturing process a tedious work to maintain the efficiency of the production unit. The data from all these instances should be monitored to maintain the integrity of the manufacturing service system, all these data are computed in the cloud environment which leads to the latency in the performance of the smart manufacturing service system. Instead, validating data from the external device, we propose to validate the data at the front-end of each device. The validation process can be automated by script validation and then the processed data will be sent to the cloud processing and storing unit. Along with the end-device data validation we will implement the APM(Asset Performance Management) to enhance the productive functionality of the manufacturers. The manufacturing service system will be chunked into modules based on the functionalities of the machines and process instances corresponding to the time schedules of the respective machines. On breaking the whole system into chunks of modules and further divisions as required we can reduce the data loss or data mismatch due to the processing of data from the instances that may be down for maintenance or malfunction ties of the machinery. This will help the admin to trace the individual domains of the smart manufacturing service system that needs attention for error recovery among the various process instances from different machines that operate on the various conditions. This helps in reducing the latency, which in turn increases the efficiency of the whole system

Dielectric Properties of (Ba0.7Sr0.3-3x/2Lax)(Ti0.9Zr0.1)O3 Ceramics with La3+ Substitution for Sr2+-Site ((Ba0.7Sr0.3-3x/2Lax)(Ti0.9Zr0.1)O3 세라믹의 Sr2+-자리에 대한 La3+ 치환에 따른 유전 특성)

  • Si Hyun Kim;Ju Hye Kim;Eung Soo Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.11
    • /
    • pp.465-474
    • /
    • 2023
  • The effects of La3+ substitution for Sr2+-site on the crystal structure and the dielectric properties of (Ba0.7Sr0.3-3x/2Lax) (Ti0.9Zr0.1)O3 (BSLTZ) (0.005 ≤ x ≤ 0.02) ceramics were investigated. The structural characteristics of the BSLTZ ceramics were quantitatively evaluated using the Rietveld refinement method from X-ray diffraction (XRD) data. For the specimens sintered at 1,550 ℃ for 6 h, a single phase with a perovskite structure and homogeneous microstructure were observed for the entire range of compositions. With increasing La3+ substitution (x), the unit cell volume decreased because the ionic size of La3+ (1.36 Å) ions is smaller than that of Sr2+ (1.44 Å) ions. With increasing La3+ substitution (x), the tetragonal phase fraction increased due to the A-site cation size mismatch effect. Dielectric constant (εr) increased with the La3+ substitution (x) due to the increase in tetragonality (c/a) and the average B-site bond valence of the ABO3 perovskite. The BSLTZ ceramics showed a higher dielectric loss due to the smaller grain size than that of (Ba0.7Sr0.3)(Ti0.9Zr0.1)O3 ceramics. BSLTZ (x = 0.02) ceramics met the X7R specification proposed by the Electronic Industries Association (EIA).

Effect of Substrata Surface Energy on Light Scattering of a Low Loss Mirror (기판의 표면에너지가 반사경의 산란에 미치는 영향)

  • Lee, Beom-Sik;Yu, Yeon-Serk;Lee, Jae-Cheul;Hur, Deog-Jae;Cho, Hyun-Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.452-460
    • /
    • 2007
  • Ultra-low loss ZERODUR and fused silica mirrors were manufactured and their light scattering characteristics were investigated. For this purpose, ZERODUR and fused silica substrates were super-polished by the bowl feed method. The surface roughness were 0.292 ${\AA}$ and 0.326 ${\AA}$ in rms for ZERODUR and fused silica, respectively. To obtain the high reflectivity, 22 thin film layers of $SiO_2$ and $Ta_2O_5$ were deposited by Ion Beam Sputtering. The measured light scattering of ZERODUR and fused silica mirror were 30.9 ppm and 4.6 ppm, respectively. This shows that the substrate surface roughness is not the only parameter which determines the light scattering of the mirror. In order to investigate the mechanism for additional light scattering of the ZERODUR mirror, the surface roughness of the mirror was measured by AFM and was found to be 2.3 times higher than that of the fused silica mirror. It is believed that there is some mismatch at the interface between the substrate and the first thin film layer which leads to the increased mirror surface roughness. To clarify this, the contact angle measurements were performed by SEO 300A, based on the Giriflaco-Good-Fowkes-Young method. The fused silica substrates with 0.46 ${\AA}$ in its physical surface roughness shows lower contact angle than that of the ZERODUR substrate with 0.31 ${\AA}$. This indicates that the thin film surface roughness is determined by not only its surface roughness but also the surface energy of the substrate, which depends on the chemical composition or crystalline orientation of the materials. The surface energy of each substrate was calculated from a contact angle measurement, and it shows that the higher the surface energy of the substrate, the better the surface roughness of the thin film.

Microsatellite Alterations of Plasma DNA in Non Small Cell Lung Cancer (비소세포폐암 환자의 혈장 DNA를 이용한 Microsatellite 분석)

  • Kim, Kyu-Sik;Kim, Eun-Jung;Kim, Soo-Ock;Oh, In-Jae;Park, Chang-Min;Jeong, Ju-Yeon;Kim, Yu-Il;Lim, Sung-Chul;Park, Jong-Tae;Kim, Young-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.4
    • /
    • pp.352-358
    • /
    • 2005
  • Microsatellites are short tandem repeated nucleotide sequences that are present throughout the human genome. Variations in the repeat number or a loss of heterozygosity around the microsatellites have been termed a microsatellite alteration (MA). A MA reflects the genetic instability caused by an impairment in the DNA mismatch repair system and is suggested to be a novel tumorigenic mechanism. A number of studies have reported that MA in the DNA extracted from the plasma occurs at varying frequencies among patients with a non-small cell lung carcinoma (NSCLC). The genomic DNA from 9 subjects with a non-small cell lung cancer (squamous cell cancer 6, adenocarcinoma 2, non-small cell lung cancer1) and 9 age matched non-cancer control subjects (AMC: tuberculosis 3, other inflammatory lung disease 6) and 12 normal control subjects (NC) were extracted from the peripheral blood leukocytes and plasma. Three microsatellite loci were amplified with the primers targeting the Gene Bank sequence D21S1245, D3S1300, and D3S1234. MA in the form of an allelic loss or a band shift was examined with 6% polyacrylamide gel electrophoresis and silver staining. None (0/12) of the NC subjects less than 40 years of age showed a MA in any of the three markers, while 88.9%(8/9) of the AMC above 40 showed a MA in at least one of the three markers (p<0.05). Sixty percent(6/10) of the control subjects with a smoking history showed a MA in one of the three markers, while 9.1%(1/11) of the control subjects without smoking history showed a MA (p<0.05). However, not only did 66.7%(6/9) of lung cancer patients show a MA in at least one of the three markers but so did 88.9%(8/21) of the AMC patients (p>0.05). In conclusion, a MA in the D21S1245, D3S1300, and D3S1234 loci using DNA extracted from the plasma was detected in 66.7% of lung cancer while no MA was found in the young non-smoking control subjects. However, many of the non-cancer control subjects (aged smokers) also showed a MA, which compromised the specificity of the MA analysis as a screening test. Therefore, a further study with a larger sample size will be needed.