• 제목/요약/키워드: Mirror 2.0

검색결과 272건 처리시간 0.06초

SPATIALLY RESOLVED KINEMATICS OF GAS AND STARS IN HIDDEN TYPE 1 AGNS

  • Son, Donghoon;Woo, Jong-Hak;Eun, Da-In;Cho, Hojin;Karouzos, Marios;Park, Songyeon
    • 천문학회지
    • /
    • 제53권5호
    • /
    • pp.103-115
    • /
    • 2020
  • We analyze the spatially resolved kinematics of gas and stars for a sample of ten hidden type 1 AGNs in order to investigate the nature of their central sources and the scaling relation with host galaxy stellar velocity dispersion. We select our sample from a large number of hidden type 1 AGNs, which are identified based on the presence of a broad (full width at half maximum ≳1000 km s-1) component in the Hα line profile and which are frequently mis-classified as type 2 AGNs because AGN continuum and broad emission lines are weak or obscured in the optical spectral range. We used the Blue Channel Spectrograph at the 6.5-m Multiple Mirror Telescope to obtain long-slit data with a spatial scale of 0.3 arcsec pixel-1. We detected broad Hβ lines for only two targets; however, the presence of strong broad Hα lines indicates that the AGNs we selected are all low-luminosity type 1 AGNs. We measured the velocity, velocity dispersion, and flux of stellar continuum and gas emission lines (i.e., Hβ and [O III]) as a function of distance from the center. The spatially resolved gas kinematics traced by Hβ or [O III] are generally similar to the stellar kinematics except for the inner center, where signatures of gas outflows are detected. We compare the luminosity-weighted effective stellar velocity dispersions with the black hole masses and find that our hidden type 1 AGNs, which have relatively low back hole masses, follow the same scaling relation as reverberation-mapped type 1 AGN and more massive inactive galaxies.

폴리 실리콘 위에서 나노결정질 다이아몬드 박막 성장 (Growth of Nanocrystalline Diamond Films on Poly Silicon)

  • 김선태;강찬형
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.352-359
    • /
    • 2017
  • The growth of nanocrystalline diamond films on a p-type poly silicon substrate was studied using microwave plasma chemical vapor deposition method. A 6 mm thick poly silicon plate was mirror polished and scratched in an ultrasonic bath containing slurries made of 30 cc ethanol and 1 gram of diamond powders having different sizes between 5 and 200 nm. Upon diamond deposition, the specimen scratched in a slurry with the smallest size of diamond powder exhibited the highest diamond particle density and, in turn, fastest diamond film growth rate. Diamond deposition was carried out applying different DC bias voltages (0, -50, -100, -150, -200 V) to the substrate. In the early stage of diamond deposition up to 2 h, the effect of voltage bias was not prominent probably because the diamond nucleation was retarded by ion bombardment onto the substrate. After 4 h of deposition, the film growth rate increased with the modest bias of -100 V and -150 V. With a bigger bias condition(-200 V), the growth rate decreased possibly due to the excessive ion bombardment on the substrate. The film grown under -150V bias exhibited the lowest contact angle and the highest surface roughness, which implied the most hydrophilic surface among the prepared samples. The film growth rate increased with the apparent activation energy of 21.04 kJ/mol as the deposition temperature increased in the range of $300{\sim}600^{\circ}C$.

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

선형가열기를 이용한 SillSiO2/Si3N4llSi 이종기판쌍의 직접접합 (Direct Bonding of SillSiO2/Si3N4llSi Wafer Fairs with a Fast Linear Annealing)

  • 이상현;이상돈;송오성
    • 한국전기전자재료학회논문지
    • /
    • 제15권4호
    • /
    • pp.301-307
    • /
    • 2002
  • Direct bonded SOI wafer pairs with $Si ll SiO_2/Si_3N_4 ll Si$ the heterogeneous insulating layers of SiO$_2$-Si$_3$N$_4$are able to apply to the micropumps and MEMS applications. Direct bonding should be executed at low temperature to avoid the warpage of the wafer pairs and inter-diffusion of materials at the interface. 10 cm diameter 2000 ${\AA}-SiO_2/Si(100}$ and 560 $\AA$- ${\AA}-Si_3N_4/Si(100}$ wafers were prepared, and wet cleaned to activate the surface as hydrophilic and hydrophobic states, respectively. Cleaned wafers were pre- mated with facing the mirror planes by a specially designed aligner in class-100 clean room immediately. We employed a heat treatment equipment so called fast linear annealing(FLA) with a halogen lamp to enhance the bonding of pre mated wafers We kept the scan velocity of 0.08 mm/sec, which implied bonding process time of 125 sec/wafer pairs, by varying the heat input at the range of 320~550 W. We measured the bonding area by using the infrared camera and the bonding strength by the razor blade clack opening method, respective1y. It was confirmed that the bonding area was between 80% and to 95% as FLA heat input increased. The bonding strength became the equal of $1000^{\circ}C$ heat treated $Si ll SiO_2/Si_3N_4 ll Si$ pair by an electric furnace. Bonding strength increased to 2500 mJ/$\textrm{m}^2$as heat input increased, which is identical value of annealing at $1000^{\circ}C$-2 hr with an electric furnace. Our results implies that we obtained the enough bonding strength using the FLA, in less process time of 125 seconds and at lowed annealing temperature of $400^{\circ}C$, comparing with the conventional electric furnace annealing.

원적외선용 반사식 전방위 비전 시스템의 광학 설계 (Optical Design of a Reflecting Omnidirectional Vision System for Long-wavelength Infrared Light)

  • 주윤재;조재흥;유재명
    • 한국광학회지
    • /
    • 제30권2호
    • /
    • pp.37-47
    • /
    • 2019
  • 야간 감시를 위해 원적외선에서 사용하는 4개의 구면 및 비구면 거울을 갖는 반사식 전방위 비전 시스템 광학계를 제안한다. 이 반사식 전방위 비전 시스템은 유사 카세그레인식 수광부 반사경 시스템과 역 유사 카세그레인식 결상부 반사경 시스템으로 설계되었으며, 그에 따른 설계 과정과 성능 분석을 상세히 제시한다. 이 비전 시스템의 반화각과 F-수는 각각 $40{\sim}110^{\circ}$와 1.56으로 설정하였다. 그리고 원적외선 파장 영역에서 비전 시스템을 사용하기 위해서 상의 크기가 원적외선용 마이크로 볼로미터의 크기와 가능한 같아야 하므로 상의 크기를 $5.9mm{\times}5.9mm$에 맞추어 설계를 진행하였다. 최적화 설계 후 $40{\sim}110^{\circ}$의 반화각 범위에서의 상 크기의 비율은 48.86%이며, 나이퀴스트 주파수인 20 lp/mm의 공간주파수에서 원적외선의 변조전달함수 값이 0.381에 도달하였다. 또한 20 lp/mm의 공간주파수에서 원적외선 영역에 대한 공차의 누적 확률은 99.75%였다. 또한 역 유사 카세그레인식 구조의 결상부 부경을 온도 변화에 따른 변조전달함수 값을 개선시키는 보상자로 선택하여 반사식 전방위 비전 시스템의 운용 온도 범위인 $-32^{\circ}C$에서 $+55^{\circ}C$의 온도 범위에서 비열화 해석 및 보상화 과정을 진행하였다.

45nm CMOS 공정기술에 최적화된 저전압용 이득-부스팅 증폭기 기반의 1.1V 12b 100MS/s 0.43㎟ ADC (A 1.1V 12b 100MS/s 0.43㎟ ADC based on a low-voltage gain-boosting amplifier in a 45nm CMOS technology)

  • 안태지;박준상;노지현;이문교;나선필;이승훈
    • 전자공학회논문지
    • /
    • 제50권7호
    • /
    • pp.122-130
    • /
    • 2013
  • 본 논문에서는 주로 고속 디지털 통신시스템 응용을 위해 고해상도, 저전력 및 소면적을 동시에 만족하는 45nm CMOS 공정으로 제작된 4단 파이프라인 구조의 12비트 100MS/s ADC를 제안한다. 입력단 SHA 회로에는 높은 입력 주파수를 가진 신호가 인가되어도 12비트 이상의 정확도로 샘플링할 수 있도록 게이트-부트스트래핑 회로가 사용된다. 입력단 SHA 및 MDAC 증폭기는 요구되는 DC 이득 및 높은 신호스윙을 얻기 위해 이득-부스팅 구조의 2단 증폭기를 사용하며, 넓은 대역폭과 안정적인 신호정착을 위해 캐스코드 및 Miller 주파수 보상기법을 선택적으로 적용하였다. 채널길이 변조현상 및 전원전압 변화에 의한 전류 부정합을 최소화하기 위하여 캐스코드 전류 반복기를 사용하며, 소자의 부정합을 최소화하기 위하여 전류 반복기와 증폭기의 단위 넓이를 통일하여 소자를 레이아웃 하였다. 또한, 제안하는 ADC에는 전원전압 및 온도 변화에 덜 민감한 저전력 기준 전류 및 전압 발생기를 온-칩으로 집적하는 동시에 외부에서도 인가할 수 있도록 하여 다양한 시스템에 응용이 가능하도록 하였다. 제안하는 시제품 ADC는 45nm CMOS 공정으로 제작되었으며 측정된 DNL 및 INL은 각각 최대 0.88LSB, 1.46LSB의 값을 가지며, 동적성능은 100MS/s의 동작속도에서 각각 최대 61.0dB의 SNDR과 74.9dB의 SFDR을 보여준다. 시제품 ADC의 면적은 $0.43mm^2$ 이며 전력소모는 1.1V 전원전압 및 100MS/s 동작속도에서 29.8mW이다.

화이버 기관지경 검사의 임상적 고찰 (A Clinical Study on Fiberoptic Bronchoscopy)

  • 이상기;홍영호;권평중;김중환
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1981년도 제15차 학술대회연제순서 및 초록
    • /
    • pp.3.2-3
    • /
    • 1981
  • 1978년 2월부터 1981년 2월까지의 3년간 중앙대학교이비인후과에서 화이버기관지경 검사를 시행한 예중 화이버기관지경에 의한 진단이나, 병리조직학적 진단이 확실한 55례에 대하여 통계학적으로 분석 검토하여 다음과 같은 결과를 얻었기에 문헌적 고찰과 함께 보고하는 바이다. 1) 성별로는 남자 41명, 여자 14명으로 3 : 1로 남자가 더 많았다. 2) 연령별로는 50∼59세 군이 가장 많은 분포를 보였으며 (15례, 27.2%), 40대, 60대, 70대 사이에서는 커다란 차이점이 없음을 발견하였다. 3) 성별로는 가장 많은 빈도를 보인 50대 에서는 남자 12명 여자 3명으로 남녀간에 4 : 1의 비율을 보였다. 4) 주소는 기침(52%), 혈담(25%), 호홉곤란(23.6%), 흉통(18%), 가슴답답(9%)의 순으로 많았다. 5) 기관지 흡입물을 그람 염색하여 세균이 발견되지 않은 것이 33례(60%)로 가장 많았고, 그람양성구균 2례 (3.6%), 그람음성구균 2례 (3.6%), 그람양성간상균 1례 (1.8%), 그람음성간상균 2례 (3.6%), 혼합균이 15례 (27.2%)이고 혼합균중 그람음성간상균이 13예로서 가장 많았다. 6) 기관지 흡입물의 배양결과는 28례 (50.9%)에서, 자라지 않았고, 알파용혈성 연쇄상구균 10례 (18.2%), 나이세리아속 7례 (12.7%), 크레브시엘라 2례(3.6%) 슈도모나스 2례 (3.6%)이었고, 혼합균은 6례 (10.9%)이고 혼합균중 알파용혈성 연쇄상구균이 6례로서 가장 많았다. 7) 임상적, 검사실성적, 조직적, 기관지경검사에 의해 얻은 진단에 의하면 기관지암 21례 (38.1%), 폐결핵8례 (14.5%), 늑막염 3례 (5.4%), 기관지염 7례 (12.7%), 폐렴 4례 (7.2%), 기관지확장증 4례 (7.2%), 무기폐 4례 (7.2%)의 순으로 많았다.경우보다 높은 2.0 unit/mL의 농도에서 알파-갈 항원결정인자가 제거되는 양상을 보였다. 걸론: 돼지의 대동맥 판막 조직과 심낭 조직의 알파-갈 항원결정인자는 eriffonia simplicifolia의 동종렉틴 B4를 사용한 면역조직형광염색에서 잘 염색되었으며 이를 알파-갈락토시다아제를 사용하여 제거하였을 때 각각 1.0 unit/mL, 2.0 unit/mL 농도의 녹색콩 알파-갈락토시다아제를 $4^{\circ}C$, pH 6.5의 조건에서 24시간 반응시켰을 때 효과적으로 상당량 제거할 수 있었다. 향후 돼지의 판막조직 및 심낭조직으로 만드는 조직판막의 내구성 증대에 대표적인 동물 면역항원인 알파-갈 항원결정인자의 제거가 유용한 도구가 될 수 있을 것이며 앞으로 알파-갈락토시다아제로 처리한 돼지의 조직판막에 대한 인간혈장의 항-갈 항체 및 항-갈 단클론항체를 이용한 직접적인 면역학적 연구가 필요하다.광학거울 (Fine-grade optical mirror)을 이 부위에 넣고 반사시야에서 수술적 처치를 시행할 것을 주장했으나, 수술시의 출혈등에 의한 명료시야의 확보에 문제점이 있어 널리 시행되지 않았다. Saito(1971)등은 Sinus tympani의 접근방법으로서 종래의 중이강내에서 접근방식 (Tympani approach) 보다 유양동을 통한 접근(mastoid approach)이 보다 편리하고 확실한 방법일 것이라는 생각으로 42개의 측두골에 대한 미세해부학적 계측을 실시하였다. 그러나 연구결과에서 그는 Sinus tympani의 상부는 안면신경과 지나치게 가까운 거리에 있어 접근이 용이하지 않았고 후부는 이낭(Otic capsule)에서 발생한 중치밀골(Hard compact bone)로 되어 있으며 안면신경 과 후반규관 사이가 협소하여 수술시 micro-drill burr로서 제거하기가 용이치 않다

  • PDF

익산지역 유치원 아동의 이중치와 결손치의 발생빈도에 관한 조사 연구 (THE PREVALENCE OF DOUBLE TEETH AND CONGENITAL MISSING TEETH IN PRESCHOOL CHILDREN OF IKSAN CITY)

  • 주진형;이광희;김대업;정영남
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.210-216
    • /
    • 2003
  • 이중치는 쌍생치와 융합을 포함한다. 선천적인 결손치는 치아가 하나이상 없는 상태를 의미한다. 이 연구의 목적은 익산시 유치원 어린이에서의 이중치와 선천적 결손치의 유병율을 조사하는 것이다. 조사 인원은 569명의 남아와 462명의 여아로 1,031명의 어린이를 대상으로 하였으며 연령은 17개월에서 84개월의 연령이내였다. 이중치는 다양한 진단학적 치료적 문제를 가진다. 쌍생치는 하나의 치배가 두개의 치관을 형성하는 것으로 정의되며 임상적으로 동일한 두 개의 치관이 나뉘어져 거울상(mirror image)으로 보이게 된다. 융합치는 두 개의 치배가 합쳐져서 형성된 것으로 물리적인 힘이나 압력이 두 개의 정상적으로 분리된 치배를 접촉시켜 발생하는 것으로 알려져 있다. 융합은 두개의 정상치아 사이에서 나타나거나 혹은 정상치아와 과잉치 사이에서 나타나는데 후자의 경우 쌍생치와 구별하기 힘들다. 1,031명중 23명(11명의 남아, 12명의 여아)이 이중치를 보이고 17명(8명 남아, 9명 여아)은 선천적 결손치를 보였다. 이중치의 유병율은 2.2%였다. 선천적 결손치의 유병율은 1.6%였다. 피검자중 1명은 이중치와 결손치를 가지고 있었다. 유치열기의 이중치와 선천적 결손치에서 모두 남녀간에 통계학적으로 유의한 차이가 없었다(p>0.05).

  • PDF

실시간 3차원 검안경의 광학설계 (Optical System Design for Real-Time 3-Dimension Ophthalmoscope)

  • 이숙희;양연식;최오목;심상현;두하영
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.35-39
    • /
    • 2003
  • 본 연구는 안과 실명 질환의 가장 많은 부분을 차지하는 망막을 실시간으로 3차원 영상화하기 위한 장치의 광학설계에 관한 것이다. 3차원 망막 영상을 얻기 위해 광원으로 He-Ne 레이저를 사용하였으며, 이는 초점 조절을 위한 슬래지부, 안구의 망막을 스캔하는 2차원 평면 주사선을 위한 scan system부, 그리고 망막에서 반사되어 나오는 반사 선을 센서로 보내주기 위한 반사 광학계부로 구성되어 있다. 구성된 시스템들은 레이저빔의 입사각과, 망막으로부터 반사되는 레이저 반사 가상선의 출사각을 일정하게 유지하게 했으며, 또한 망막에서 레이저빔의 입사와 반사가상선의 출사가 수직 및 수평 방향으로 일치시키도록 하였다. 이렇게 구성되어진 각 부운을 광학설계 프로그램인 Code-V를 이용하여 설계하였고, 최적화하였다. 결론적으로 3차원 망막 영상을 얻기 위한 장치의 최적 시스템을 다시 구성 하기전, 해상력이 높은 망막의 영상을 얻을 수 있는 광학장치를 구성하기 위하여 광학설계 프로그램인 Code-V를 이용하여 초기설계를 하고 최적화를 하였다. 그 결과 광학 수차가 적고 높은 해상력을 갖는 광학 시스템을 구현할 수 있는 광학적 데이터를 얻을 수 있었다.

  • PDF