• 제목/요약/키워드: Minimum phase system

검색결과 329건 처리시간 0.031초

Nonlinear State Feedback for Minimum Phase in Nuclear Steam Generator Level Dynamics

  • Jeong, Seong-Uk;Choi, Jung-In
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권3호
    • /
    • pp.66-70
    • /
    • 1997
  • The steam generator level is susceptible to the nonminimum phase in dynamics due to the thermal reverse effects known as "shrink and swell" in a pressurized water reactor. A state feedback assisted control concept is presented for the change of dynamic performance to the minimum phase the concept incorporates a nonlinear digital observer as a part of the control system. The observer is deviced to estimate the state variables that provide the true indication of water inventory by compensating for shrink and swell effects. The concept is validated with implementation into the steam generator simulation model.

  • PDF

Limited Feedback Designs for Two-Way Relaying Systems with Physical Network Coding

  • Kim, Young-Tae;Lee, Kwangwon;Jeon, Youngil;Lee, Inkyu
    • Journal of Communications and Networks
    • /
    • 제17권5호
    • /
    • pp.463-472
    • /
    • 2015
  • This paper considers a limited feedback system for two-way wireless relaying channels with physical network coding (PNC). For full feedback systems, the optimal structure with the PNC has already been studied where a modulo operation is employed. In this case, phase and power of two end node channels are adjusted to maximize the minimum distance. Based on this result, we design new quantization methods for the phase and the power in the limited feedback system. By investigating the minimum distance of the received constellation, we present a code-book design to maximize the worst minimum distance. Especially, for quantization of the power for 16-QAM, a new power quantization scheme is proposed to maximize the performance. Also, utilizing the characteristics of the minimum distance observed in our codebook design, we present a power allocation method which does not require any feedback information. Simulation results confirm that our proposed scheme outperforms conventional systems with reduced complexity.

최소 샘플링의 고속푸리에 변환을 이용한 비정상 계통의 향상된 위상추종 및 고조파 검출 기법 (Improved Phase and Harmonic Detection Scheme using Fast Fourier Transform with Minimum Sampling Data under Distorted Grid Voltage)

  • 김현수;김경화
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.72-80
    • /
    • 2015
  • In distributed generation systems, a grid-connected inverter should operate with synchronization to grid voltage. Considering that synchronization requires the phase angle of grid voltage, a phase locked loop (PLL) scheme is often used. The synchronous reference frame phase locked loop (SRF-PLL) is generally known to provide reasonable performance under ideal grid voltage. However, this scheme indicates performance degradation under the harmonic distorted or unbalanced grid voltage condition. To overcome this limitation, this paper proposes a phase and harmonic detection method of grid voltage using fast Fourier transform (FFT). To reduce the calculation time of FFT algorithm, minimum sampling data is taken from the voltage measurement to determine the phase angle and the magnitude of harmonic components. An experimental test setup for a grid-connected inverter system has been constructed. By comparative simulations and experiments under various abnormal grid voltage conditions, the proposed scheme has been proven to effectively track the phase angle of the grid voltage.

GPS 에 있어서의 의사잡음위상변조 통신방식에 대한 연구 (A Study on PN Phase Modulation Communication System in GPS)

  • 정세모;고광섭
    • 한국항해학회지
    • /
    • 제6권2호
    • /
    • pp.13-33
    • /
    • 1982
  • The NAVSTAR/GPS is a satellite-based navigation system that will provide extremely accurate three-dimensional position and velocity information to users anywhere on or near the earth. This system has been studied primarly for military use and thus the results of studies are seldom obtainable for civilian use up to date. Expecting this system to be opened to civilian use in the future, this paper aims to the collection of basic data of the PN phase modulated communication system adopted in the GPS system by computer simulation. The results of studies are as follows; 1) The PN phase modulation of the speed of 106b/s can be simulated by Fourier summation, the spectrum region which can be restricted is in the region of 0.5-1.5 MHz and spectrum number required is over than 270. 2) By computer simulation, it is verified that optimum r.f filter bandwidth is about 0.3 MHz for the case of $10^6$b/s PN codes phase modulated in 1.575GHz carrier. 3) In case that PN rate to data rate is between 10 and 100, the allowable minimum SNR to demodulate data signal correctly by optimum LPF is about 0.3. It is also verified that the larger the frequency ratio of PN code to the data code, the lower the allowable minimum SNR required.

  • PDF

MSTC를 이용한 7상 BLDC 모터 구동시스템 (7-Phase BLDC Motor Drive System using MSTC)

  • 전윤석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.429-433
    • /
    • 2000
  • Recently the demand of motor for industrial household machinery is increasing. As Switching devices and control technology are progressing so the use of BLDC Motor is increasing But 3-Phase BLDC Motor generally used has pulsating torque and speed variation in commutation so the range of it's application is limited high speed application Especially to solve these problems it is necessary to increase phase to Motor so study of Poly-Phase BLDC Motor is progressing. In this paper we designed 7-Phase BLDC Motor drive system and MSTC(Minimum Switching Time Controller)

  • PDF

Microcontroller-Based Improved Predictive Current Controlled VSI for Single-Phase Grid-Connected Systems

  • Atia, Yousry;Salem, Mahmoud
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1016-1023
    • /
    • 2013
  • Predictive current control offers the potential for achieving more precise current control with a minimum of distortion and harmonic noise. However, the predictive method is difficult to implement and has a greater computational burden. This paper introduces a theoretical analysis and experimental verification for an improved predictive current control technique applied to single phase grid connected voltage source inverters (VSI). The proposed technique has simple calculations. An ATmega1280 microcontroller board is used to implement the proposed technique for a simpler and cheaper control system. To enhance the current performance and to obtain a minimum of current THD, an improved tri-level PWM switching strategy is proposed. The proposed switching strategy uses six operation modes instead of four as in the traditional strategy. Simulation results are presented to demonstrate the system performance with the improved switching strategy and its effect on current performance. The presented experimental results verify that the proposed technique can be implemented using fixed point 8-bit microcontroller to obtain excellent results.

비최소 위상 시스템의 역변환 문제에 대한 실험적 고찰 (An experimental study on an inverse problem of a non-minimum phase system)

  • 노경래;이상권
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.147-150
    • /
    • 2001
  • 본 논문은 비최소 위상을 가지는 시스템에 대한 역변환 문제를 실험적으로 고찰, 연구하였다. 일반적으로 선형적이고 인과적인 시스템의 입$cdot$ 출력관계는 행렬형태로 공식화할 수 있다. 최소위상(minimum phase) 시스템의 시스템행렬은 항상 역행렬이 존재하며 안정적이지만 비최소 위상(non-minimum phase)시스템의 시스템행렬은 근사특이(near-singular)행렬 또는 특이(singular) 행렬이므로 불량조건(ill-conditioning)이 발생하고 역변환이 존재할 수 없다. 비최소 위상 시스템의 역변환 문제는 다른 과정을 포함하지 않고서는 인과적이고 안정적인 역변환 필터를 가질 수 없다. 따라서 역변환 필터의 구현을 위해 SVD(singular value decomposition)를 이용하였다. 비최소 위상 시스템인 경우 시스템행렬은 하나이상의 매우 작은 특이 값을 가지며 이것은 시스템의 위상정보를 가진다. 이 성질을 이용하여 시스템의 근사적인 역변환 필터를 구현하고 비최소 위상을 갖는 외팔보에 대해 실험적으로 검증하였다.

  • PDF

영전압 스위칭을 이용한 고역률 3상 AC-DC Flyback 컨버터 모듈 (High Power Factor Three-phase AC-DC Flyback Converter Module Using Zero Voltage Switching)

  • 이종필;최주엽;송중호;최익;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2701-2703
    • /
    • 1999
  • A new mode of parallel operation of a modular 3-phase AC-DC Flyback converter for high power factor correction along with tight regulation is presented in this thesis. The converter offers input/output transformer isolation for safety, a unity input power factor for minimum reactive power, high efficiency and high power density for minimum weight and volume. Compared with previously developed 3-phase two-stage power converter, the advantage of the proposed converter does not require expensive high voltage and high current devices that are normally needed in popular boost type 3-phase converter. In this paper, a detailed small signal analysis of the modular 3-phase AC-DC flyback converter is provided for control purposes and also experimental results are included to confirm the validity of the analysis.

  • PDF

비 최소치목 시스템의 적의 연구 (Adaptive Control of Nonminimum Phase System)

  • Si-Chul Roh
    • 대한전기학회논문지
    • /
    • 제35권11호
    • /
    • pp.529-534
    • /
    • 1986
  • In recent year, there have been much techniques for designing globally stable adaptive control systems when the unknown plant is minimum phase. This paper presents a new seheme for indirect adaptive control structure for nonminimum phase plant of which parameters are estimated from the least-square algorithm. Its effectiveness has been demonstrated by computer simulation carried out for a second-order plant.

  • PDF

QFT를 이용한 BTT 미사일 종방향 오토파일럿 시스템의 강인제어기 설계 (Design of robust controller for the longitudinal autopilot system of BTT missile using QFT)

  • 김석우;윤경한;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.418-421
    • /
    • 1997
  • A design method of robust controller for the longitudinal autopilot of BTT missile is considered. The difficulties are a set of linearized dynamic models which corresponds to different operating points has a wide range of parameters and it has even Non-Minimum Phase(NMP) zeros. In this paper, such a family of models is expressed by an interval plant. Then a robust control design method using QFT is represented. A simulation result shows that the proposed controller satisfies the given specification well.

  • PDF