• Title/Summary/Keyword: Minimum frequency interval

Search Result 39, Processing Time 0.026 seconds

Securing Method for Available Frequency by Changing Adaptive Protection Ratio in Adjacent Station Interference Environment of FM Broadcast (FM방송의 인접국 간섭환경에서 적응적 혼신보호비 변경에 의한 가용주파수 확보 방안)

  • Kim, Gi-Young;Ryu, Heung-Gyoon
    • Journal of Broadcast Engineering
    • /
    • v.16 no.3
    • /
    • pp.490-500
    • /
    • 2011
  • The channels of domestic FM broadcast are needed to provide various kinds of new broadcasting services. However, available channels are limited and saturated. The channel interval of FM broadcast is changed from 200 kHz to 100 kHz to maximize utilization efficiency of scarce broadcast spectrum at all over the world. Also, there are many researches such as IBOC(In Band On Channel) and DRM+(Digital Radio Mondial+) that is to allocate the digital signal beside analog bandwidth. But output power is decrease to avoid interference between adjacent radio stations. In this paper, we analyzes the problems of the protection ratio which is decided in 1986 and we propose method to improve about 7~10dB significantly the protection ratio according to the recent DSP(Digital Signal Processing) techniques without loss of both transmission power and broadcast quality. In addition, we examined the possibility of securing two times available channels by reducing minimum frequency interval from 800 kHz to 400 kHz or 600 kHz in the equal site.

A Study on the Minimnum Ignition Limit for LPG-Air Mixtures by Switching Sparks in Radio-frequency Circuits (고주파 전기회로의 개폐불꽃에 의한 LPG-공기 혼합가스의 점화한계에 관한 연구)

  • Jee, S.W.;Song, H.J.;Lee, C.H.;Park, W.Z.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1854-1856
    • /
    • 1996
  • This study describes the minimum ignition limit for LPG-Ai-r mixtures by switching sparks in radio-frequency limits using RF power supply and IEC type ignition spark apparatus. As a result, the minimum ignition limit voltage is increased in proportional to the rate of increasing of frequency in LPG-Air mixed gas. Especially, increment between 10[kHz] and 30[kHz] is typical. It is considered that ignition is caused by one discharge until 10 [kHz] and, beyond 10[kHz] ignition is caused by more than two discharges. The reason is analysed that energy loss is caused by existing pause interval between discharges.

  • PDF

Ovarian Cycle, the Biological Minimum Size and Artificial Spawning Frequency in Female Meretrix petechialis (Bivalvia: Veneridae) in Western Korea

  • Jun, Je-Cheon;Kim, Yong-Min;Chung, Jae-Seung;Chung, Ee-Yung;Lee, Ki-Young
    • Development and Reproduction
    • /
    • v.16 no.3
    • /
    • pp.205-217
    • /
    • 2012
  • The ovarian cycle, the biological minimum size, and artificial spawning frequency by artificial spawning induction of the female hard clam, Meretrix petechialis, were investigated by histological observations and morphometric data. The ovarian cycle of this species can be classified into five successive stages: early active stage, late active stage, ripe stage, partially spawned stage, and spent/inactive stage. The spawning period was from June to September, and the main spawning occurred between July and August when the seawater temperature exceeds over $20^{\circ}C$. The biological minimum size (shell length at 50% of first sexual maturity) in females were 40.39 mm in shell length (considered to be two years of age), and all clams over 50.1 mm in shell length sexually matured. In this study, the mean number of the spawned eggs by spawning induction increased with the increase of size (shell length) classes. In case of artificial spawning induction for the clams > 40.39 mm, the number of spawned eggs from the clams of a sized class was gradually decreased with the increase of the number of the spawning frequencies (the first, second, and third spawning). In the experiments of artificial spawning induction during the spawning season, the interval of each spawning of this species was estimated to be 15-18 days (approximately 17 days).

Efficient Quantitative Association Rules with Parallel Processing (병렬처리를 이용한 효율적인 수량 연관규칙)

  • Lee, Hye-Jung;Hong, Min;Park, Doo-Soon
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.8
    • /
    • pp.945-957
    • /
    • 2007
  • Quantitative association rules apply a binary association to the data which have the relatively strong quantitative attributions in a large database system. When a domain range of quantitative data which involve the significant meanings for the association is too broad, a domain requires to be divided into a proper interval which satisfies the minimum support for the generation of large interval items. The reliability of formulated rules is enormously influenced by the generation of large interval items. Therefore, this paper proposes a new method to efficiently generate the large interval items. The proposed method does not lose any meaningful intervals compared to other existing methods, provides the accurate large interval items which are close to the minimum support, and minimizes the loss of characteristics of data. In addition, since our method merges data where the frequency of data is high enough, it provides the fast run time compared with other methods for the broad quantitative domain. To verify the superiority of proposed method, the real national census data are used for the performance analysis and a Clunix HPC system is used for the parallel processing.

  • PDF

Effects of solar variations on standing Alfven waves in the dayside magnetosphere: Polar observations

  • Kim, Khan-Hyuk;Takahashi, Kazue
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.23.4-23.4
    • /
    • 2008
  • In March and April 2001, the apogee (~9 Re) of the Polar spacecraft was located near the subsolar magnetopause with its orbital plane nearly parallel to a magnetic meridian plane. Polar electric and magnetic field data acquired during the two-month interval of solar maximum have been used to study fundamental standing Alfven waves near the subsolar meridian plane (magnetic local time = 1000-1400 hours) at magnetic latitudes from the equator to $\pm45$ degrees and at L values between 7 and 12. In the frequency band from 1.5 to 10 mHz, fundamental mode oscillations were identified based on high coherence (more than 0.7) and an approximately 90-degree phase shift between the azimuthal magnetic and radial electric field components. The L dependence of the fundamental frequencies is studied, and the frequencies are compared with those observed near the solar minimum interval (Takahashi et al. 2001). We found that the average frequencies in solar maximum are lower than those in solar minimum by a factor of ~2. This implies that the mass density in solar maximum is higher than that in solar minimum by a factor of ~4. Since there is a positive correlation between solar irradiance and solar activity, we suggest that the ionosphere in solar maximum produces more ions and load magnetic flux tubes with more ions.

  • PDF

Optimal Monitoring Frequency Estimation Using Confidence Intervals for the Temporal Model of a Zooplankton Species Number Based on Operational Taxonomic Units at the Tongyoung Marine Science Station

  • Cho, Hong-Yeon;Kim, Sung;Lee, Youn-Ho;Jung, Gila;Kim, Choong-Gon;Jeong, Dageum;Lee, Yucheol;Kang, Mee-Hye;Kim, Hana;Choi, Hae-Young;Oh, Jina;Myong, Jung-Goo;Choi, Hee-Jung
    • Ocean and Polar Research
    • /
    • v.39 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • Temporal changes in the number of zooplankton species are important information for understanding basic characteristics and species diversity in marine ecosystems. The aim of the present study was to estimate the optimal monitoring frequency (OMF) to guarantee and predict the minimum number of species occurrences for studies concerning marine ecosystems. The OMF is estimated using the temporal number of zooplankton species through bi-weekly monitoring of zooplankton species data according to operational taxonomic units in the Tongyoung coastal sea. The optimal model comprises two terms, a constant (optimal mean) and a cosine function with a one-year period. The confidence interval (CI) range of the model with monitoring frequency was estimated using a bootstrap method. The CI range was used as a reference to estimate the optimal monitoring frequency. In general, the minimum monitoring frequency (numbers per year) directly depends on the target (acceptable) estimation error. When the acceptable error (range of the CI) increases, the monitoring frequency decreases because the large acceptable error signals a rough estimation. If the acceptable error (unit: number value) of the number of the zooplankton species is set to 3, the minimum monitoring frequency (times per year) is 24. The residual distribution of the model followed a normal distribution. This model can be applied for the estimation of the minimal monitoring frequency that satisfies the target error bounds, as this model provides an estimation of the error of the zooplankton species numbers with monitoring frequencies.

Performance Improvement on the Combined Convolutional Coding and Binary CPFSK Modulation (Convolutional Code/Binary CPFSK 복합 전송시스템의 성능개선에 관한 연구)

  • Choi, Yang Ho;Baek, Je In;Kim, Jae Kyoon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.5
    • /
    • pp.591-596
    • /
    • 1986
  • A binary continuous phase frequency shift keying (CPFSK), whose phase is a continuous function of time and instantaneous frequency is constant, is a bandwidth efficient constant envelope signalling scheme. A transmitting signal is formed by combined coding of a convolutional encoder and a binary CPFSK modulator. The signal is transmitted throuth additive white Gaussian noise(AWGN) channel. If the received signal is detected by a coherent maximum likelihood(ML) receiver, error probability can be expressed approximately in terms of minimum Euclidean distance. We propose rate 2/4 codes for the improvement of error performance without increating the data rate per bandwidth and the receiver complexity. Its minimum Euclidean distances are compared with those of rate \ulcornercodes as a function of modulation index and observation interval.

  • PDF

Complementary feeding practices and nutritional status of children 6-23 months old: formative study in Aceh, Indonesia

  • Ahmad, Aripin;Madanijah, Siti;Dwiriani, Cesilia Meti;Kolopaking, Risatianti
    • Nutrition Research and Practice
    • /
    • v.12 no.6
    • /
    • pp.512-520
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: The 6-23 months for infants is the longest period in the "first 1,000 days" of life. This period is very important for child development, so complementary feeding (CF) practices should be optimized to maximize children's potential for growth and development. The aim of this study was to analyze the CF practices and nutritional status of children aged 6-23 months. SUBJECTS/METHODS: For this cross-sectional study, 392 children aged 6-23 months were selected using stratified random sampling. Socio-demographic data were collected through interviews. CF practices, collected by interviews and repeated 24-hour food recall method, were the timely introduction of CF, minimum meal frequency, dietary diversity and minimum acceptable diet, consumption food rich in proteins and vitamin A. Nutritional status was assessed using the indicators of underweight, wasting and stunting. To analyze the association between socio-demographic indicators and CF with nutritional status, the chi-square test with a confidence interval of 95% was used. RESULTS: Results showed that 39% were exclusively breastfed, only 61% received prolonged breastfeeding and 50% received timely introduction of CF. Minimum meal frequency was met by 74% of subjects, but dietary diversity and minimum acceptable diet were only realized in 50% and 40% of the children, respectively. The prevalence of underweight, wasting, and stunting were 26%, 23%, and 28%, respectively. Age of the child, birth order, birth weight, parents' education level, family size and incidence of fever and diarrhea during the previous two weeks were associated with underweight, while child's birth order, fathers' education level, mother's age, family size, completion of the age-appropriate vaccination and fish consumption frequency were associated with wasting. Age of the child, incidence of fever and acute respiratory infection, and fortified food consumption were associated with stunting. CONCLUSIONS: Suboptimal CF practices and high prevalence of underweight, wasting and stunting were found among children aged 6-23 months old in Aceh. These results highlight the need to improve CF and nutritional status.

A Study on an Optimal Respiration Rate for the ANS Assessment based on RSA Analysis (RSA분석과 자율신경기능을 평가하는 호흡주기 설정에 관한 연구)

  • Lee, Sang-Myung;Lee, Sung-Jun;Ahn, Jae-Mok;Kim, Jeom-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.503-511
    • /
    • 2007
  • Heart rate variability(HRV) is the clinical consequence of various influences of the autonomic nervous system(ANS) on heart beat. HRV can estimate the potential physiologic rhythm from the interval between consecutive beats(RR interval or HRV data), but cardiovascular system governed by ANS is in relation to respiration and autonomic regulation. It is known as RSA representing respiration-related HR rhythmic oscillation. Because the mechanism linking the variability of HR to respiration is complex, it has so far been unknown well. In this paper, we tried to evaluate 5-min RR interval segments under control of respiration in order to find out a proper respiration rate that can estimate the ANS function. 10 healthy volunteers were included to evaluate 5-min HRV data under 4 different respiration-controlled environments; 0.03Hz, 0.1Hz, 0.2Hz, and 0.4Hz respiration. HRV data were analyzed both in the frequency and the time domain, with cross-correlation coefficient(cross-coeff.) for HRV and respiration signal. The results showed maximum cross-coeff. of 0.84 at 0.1 Hz and minimum that of 0.16 at 0.4Hz respiration. Cross-coeff was decreased at a faster rate from 0.1Hz respiration. All mean SDNN, RMSSD, and pNN50 of time domain measures were 108.7ms, 71.85ms, and 28.47%, respectively, and LF, HF, and TP of frequency domain measures were $12,722ms^2,\;658.8ms^2$, and $7,836.64ms^2$ at 0.1Hz respiration, respectively. In conclusion, 0.1Hz respiration was observed to be very meaningful from time domain and frequency domain analysis in relation to respiration and autonomic regulation of the heart.

Characteristics of Echolocation Calls of the Parti-coloured Bat, Vespertilio sinensis, in Relation to Environment Type (환경특성에 따른 안주애기박쥐(Vespertilio sinensis)의 반향정위 특징)

  • Chung, Chul-Un;Han, Sang-Hoon
    • Journal of Environmental Science International
    • /
    • v.24 no.3
    • /
    • pp.353-358
    • /
    • 2015
  • In this study, we analyzed two types of echolocation calls used by the parti-coloured bat, Vespertilio sinensis. Bats were captured in the Naejangsan National Park in October 2013. Call sounds of hand-released bats were recorded at the location of capture within the National Park. We analyzed pulse duration (PD), pulse interval (PI), peak frequency (PF), maximum frequency ($F_{MAX}$), minimum frequency ($F_{MIN}$), and bandwidth (BW). V. sinensis emitted the different types of the echolocation calls depending on the surrounding environment. Frequency modulated-constant frequency (FM-CF) signal of audible range was emitted when they flew in the uncluttered space over the canopy. However, when flying in the cluttered space below the canopy, they only emitted FM signal. FM-CF signal is in the audible range (e.g., low frequency), and FM signal has a harmonic broadband frequency range of two. There were significant differences in PD, PI, PF, FMAX, FMIN, and BW between the calls emitted over and below the canopy. Considering the functional characteristics of FM and CF signals, we conclude that the foraging activity of V. sinensis was observed below the canopy, and recommend the use of FM signal and broadband as echolocation signals.