• 제목/요약/키워드: Minimal surface system

검색결과 72건 처리시간 0.031초

고압동결고정을 이용한 애기장대 줄기의 cryo-SEM 분석법 (Cryo-SEM Methodology of Arabidopsis thaliana Stem Using High-Pressure Freezing)

  • 최윤정;이경환;제아름;채희수;장지훈;이은지;권희석
    • Applied Microscopy
    • /
    • 제42권2호
    • /
    • pp.111-114
    • /
    • 2012
  • The scanning electron microscopy is an ideal technique for examining plant surface at high resolution. Most hydrate samples, however, must be fix and dehydrate for observation in the scanning electron microscope. Because the microscopes operate under high vacuum, most specimens, especially biological samples, cannot withstand water removal by the vacuum system without morphological distortion. Cryo-techniques can observe in their original morphology and structure without various artifacts from conventional sample preparation. Rapid cooling is the method of choice for preparing plant samples for scanning electron microscopy in a defined physiological state. As one of cryo-technique, high-pressure freezing allows for fixation of native non-pretreated samples up to $200{\mu}M$ thick and 2 mm wide with minimal or no ice crystal damage for the freezing procedure. In this study, we could design to optimize structural preservation and imaging by comparing cryo-SEM and convention SEM preparation, and observe a fine, well preserved Arabidopsis stem's inner ultrastructure using HPF and cryo-SEM. These results would suggest a useful method of cryo-preparation and cryo-SEM for plant tissues, especially intratubule and vacuole rich structure.

향기 성분의 미세캡슐화를 위한 피복물질에 대한 연구 (A Study on Wall Materials for Flavor Encapsulation)

  • 조영희;신동석;박지용
    • 한국식품과학회지
    • /
    • 제31권6호
    • /
    • pp.1563-1569
    • /
    • 1999
  • 본 연구는 분무건조를 이용한 향기성분의 미세캡슐화를 위해 maltodextrin(MD), gum arabic(GA),alkenylsuccinated modified starch(MS), gellan gum을 피복물질로 사용하여 배합비율을 최적화하는데 목표를 갖고 수행되었다. 핵물질은 특성이 다른 5종류의 향기성분을 채종유와 1 : 4의 비율로 혼합한 flavor model system으로 사용하였다. 예비실험을 통해 핵물질 : 피복물질의 비율을 1 : 4로 하였으며, MD함량은 30%로 고정하였다. GA : MS를 $2\;:\;8{\sim}8\;:\;2$의 비율로 제조하여 유화액에서의 특성을 분석한 결과, GA : MS = 4 : 6에서 유화안정성이 우수하였으며, flavor release가 가장 적었다 이 비율에 gellan gum을 $1{\sim}5%$ 첨가하여 실험한 결과, 4% 첨가한 것이 결과가 가장 우수하였다. 이상의 결과로 MD : GA : MS : gellan gum = 30 : 26.4 : 37.6 : 4의 배합비율이 분무건조를 이용한 향기성분의 미세캡슐화를 위한 피복물질의 최적 배합조건이었다.

  • PDF

학동기 소아에서 impulse oscillometry system로 측정한 폐기능 정상치 (Reference values for respiratory system impedance using impulse oscillometry in school-aged children in Korea)

  • 위영선;김형윤;정다운;박혜원;신윤호;한만용
    • Clinical and Experimental Pediatrics
    • /
    • 제50권9호
    • /
    • pp.862-867
    • /
    • 2007
  • 목 적 : IOS는 호흡 노력을 요하지 않으며 호흡기 저항을 측정하는 비침습적인 방법이다. IOS를 이용하여 국내 학동기 소아에서의 표준치를 알아보고자 하였다. 방 법 : 7-12세의 건강한 소아 92명을 대상으로 IOS를 시행하였다. IOS 결과 값과 키, 몸무게, 체표 면적, 신체 질량 지수 및 나이 등의 연관성에 대하여 선형 회귀 분석을 시행하였다. 결 과 : IOS 성공률은 92.4%였다. 키, 몸무게, 체표 면적, 신체 질량 지수, 나이 등 5가지 변수값과 Rrs 및 Xrs를 분석한 결과, 키가 의미 있는 예측 인자였으며, 5가지 변수 모두 적용한 경우 가장 설명력이 높았다. 각각의 주파수에 따라 회귀 곡선 공식을 구하였으며, 이는 이전 연구들의 표준 공식과 비슷하였다. 결 론 : IOS의 표준치를 구하였으며 이를 활용하여 다양한 호흡기 질환의 진단에 활용될 수 있을 것이라 여겨진다.

Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구 (A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology)

  • 김재민;고은경;채수철;김순애
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology는 결막상피의 표층을 떼어내기 위해 안구 표면에 cellulose acetate filter 재질을 같이 이용한다. 이 방법은 비 침습적이고 쉽게 시행할 수 있으며 환자에게 최소한의 불편감을 주며 결막표면에 반복해서 시행하여 변화를 관찰하기 위해 사용될 수 있다. 이 방법으로 결막 표면의 형태학적 연구와 squmaous metaplasia의 정도를 평가할 수 있다. 본 연구는 건성안 환자에서 impression cytology를 이용하여 결막표면을 평가하기 위해 수행되었다. 70명의 콘택트렌즈 비착용 학생을 대상으로 조사하였는데 먼저 조사 대상자들에게 McMonnies dry eye symptom questionnaire을 작성하도록 하였다. 그리고 비침습성 tear thinning time(TTT) 검사를 시행하고 다음에 침습성 검사인 Schirmer tear test(SIT), tear film break-up time(TBUT) tests 그리고 Rose-bengal staining올 시행하여 건성안 의심자를 분류하였다. 하 안구결막으로부터 결막 상피세포는 impression cytology기법으로 수집하여 PAS(Periodic Acid Schift)-haematoxylin 염색을 시행하였다. 배상세포와 결막상피세포는 광학현미경 400배에서 관찰하여 squamous metaplasia의 정도에 근거한 Nelson Grading scale에 따라 분류하였는데 이는 배상세포 밀도, 세포의 크기와 형태, 핵:세포질 비 등을 포함한다. 건성안 의심자는 상피세포의 형태적 변화, 핵의 변화, 배상세포 밀도 감소를 보였다. 세포학적 변화 정도는 건성안 조건의 정도에 관련이 있었다. 상피세포 형태를 Nelson의 분류시스템으로 단계를 나눈 결과 대조군의 91.43%가 grade 0 이었고 8.57%가 약간의 이상형태인 grade 1이었다. 반면에 건성안 의심자에서는 20%가 grade 0, 42.86%가 grade 1, 34.29%가 grade 2 그리고 2.86%가 심한 형태적 변화를 보인 grade 3를 나타냈다. Impression cytology는 부작용이나 거부반응이 없는 안구 표면 상피의 비 침습적 또는 최소 침습적 생검법으로 생각되며 안구표면을 포함하는 광범위한 과정을 위한 유용한 진단 기법으로 안전하고 간단하며 건성안 의심자의 다양한 안구 표면 변화의 이해를 증진시키는데 도움을 줄 수 있을 것으로 사료된다.

  • PDF

섬유강화형 포스트를 이용한 치관-치근 파절의 치료: 증례 보고 (TREATMENT OF CROWN-ROOT FRACTURE USING FIBER-REINFORCED POST: A CASE STUDY)

  • 임화신;라지영;이광희;안소연;김윤희;금기석;이상봉
    • 대한소아치과학회지
    • /
    • 제39권1호
    • /
    • pp.58-65
    • /
    • 2012
  • 치관-치근 파절은 법랑질, 상아질, 백악질이 모두 포함된 치아의 파절로, 파절선이 대부분 절단연이나 순측의 변연부 치은에서 구개측 치은열구 하방으로 사선으로 진행된다. 파절선의 위치가 치은 연상이라면 파절편의 제거 및 치은연상 수복을 시행하고, 치은 연하라면 파절면의 외과적 노출술, 교정적 정출술, 외과적 정출술을 이용한 치아의 수복이 이루어진다. 그 외에 섬유 강화형 포스트를 삽입하여 치관 수복물의 유지력을 높이고, 레진 접착 시스템을 사용하여 치관 파절편을 재부착함으로써 생물학적으로 최소한으로 침습적인 치료를 하는 방법도 있다. 만약 파절의 정도가 치은 연하로 깊은 경우 발치나 치관절제술을 이용한 치근의 유지 등을 고려할 수 있다. 본 증례는 치관-치근파절로 내원한 12세 환아로 섬유강화형 포스트를 사용하여 치관 파절편 재부착을 시행하였으며 양호한 경과를 보여 이를 보고하는 바이다.

ʟ-Carnitine, pyridoxine hydrochloride, ᴅʟ-α-tocopheryl acetate를 이용한 분유모델시스템의 마이얄반응생성물 저감화 조건 최적화 (Optimization of Anti-glycation Effect of ʟ-Carnitine, Pyridoxine Hydrochloride and ᴅʟ-α-Tocopheryl Acetate in an Infant Formula Model System Using Response Surface Methodology)

  • 정혜림;남미현;홍충의;표민철;오준구;김용기;최유영;권정일;이광원
    • 한국식품과학회지
    • /
    • 제47권1호
    • /
    • pp.95-102
    • /
    • 2015
  • 본 연구는 분유모델시스템에 $\small{L}$-carnitine, pyridoxine hydrochloride, $\small{DL}$-${\alpha}$-tocopheryl acetate를 첨가하여 Maillard 반응에 의해 생성된 MRPs를 저감화 시키기 위한 최적조건을 찾기 위해 RSM의 CCD를 이용하였다. $\small{L}$-Carnitine ($X_1$), pyridoxine hydrochloride($X_2$), $\small{DL}$-${\alpha}$-tocopheryl acetate ($X_3$)의 농도를 독립변수로 하고 형광도와 HMF 함량을 종속변수로 각각 설정하였다. 종속변수 회귀식의 결정계수($R^2$)는 각각 0.942, 0.861로 반응표면분석 모델에 적합하였다. 형광도와 HMF 함량은 $\small{L}$-carnitine과 pyridoxine hydrochloride의 농도가 낮을 때 $\small{DL}$-${\alpha}$-tocopheryl acetate의 농도가 감소할수록 그 값이 급격히 감소하였다. $\small{L}$-Carnitine의 농도가 높을 때 pyridoxine hydrochloride의 농도가 $20{\mu}M$ 이하로 감소할수록 형광도가 감소하였고 HMF 함량은 $\small{L}$-carnitine의 농도에 관계없이 pyridoxine hydrochloride의 농도가 $20{\mu}M$ 이하로 감소할수록 감소하는 경향을 나타냈다. 본 실험에서 분유모델시스템에서 생성된 MRPs를 저감화 할 수 있는 최적조건으로 $\small{L}$-carnitine, pyridoxine hydrochloride, $\small{DL}$-${\alpha}$-tocopheryl acetate의 농도는 각각 2.26, 15.77, $20.63{\mu}M$이었다. 이때 형광도는 77.4%였고 HMF 함량은 248.7 ppb로 각각 유단백질-유당 마이얄 반응생성물(LC, lactose+sodium caseinate)대비 MRPs를 22.6, 23.1% 감소시킬 수 있다고 예측할 수 있었다. 또한, RSM을 통해 찾은 최적 조건의 실험값으로 형광도는 79.3%였고 HMF 함량은 247.6 ppb로 각각 LC대비 MRPs를 20.7, 17.8% 감소 시켰다. 따라서, $\small{L}$-carnitine, pyridoxine hydrochloride, $\small{DL}$-${\alpha}$-tocopheryl acetate의 최적화된 혼합을 통하여 분유 제조 시 MRPs 생성을 저감화 시킬 수 있을 것으로 생각된다.

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

선박 디젤기관 스크러버의 기초설계에 관한 수치적 연구 (A Numerical Study on the Basic Design of Scrubber for Marine Diesel Engines)

  • 이원주;김인수;최용석;최재혁
    • 해양환경안전학회지
    • /
    • 제23권5호
    • /
    • pp.549-557
    • /
    • 2017
  • 본 연구에서는 강화되는 황산화물 및 입자상물질의 배출규제를 만족시키기 위한 후처리장치인 스크러버(scrubber)에 대한 수치해석적 연구를 수행하였다. 먼저 수치 해석을 통하여 기존 스크러버의 문제점을 파악하고, 이러한 문제점들을 개선할 수 있는 새로운 형태의 와류형 스크러버를 설계하여 분석하였다. 그 결과 와류형 스크러버에서 배기가스는 하부에서 와류를 형성하고 그 중 일부는 바닥면을 통과하여 가이드 베인을 따라 배출되는데, 이 때 수직 방향의 압력구배는 크지 않으나 배플의 내 외부에는 압력차가 발생하는 것으로 나타났다. 배기가스 유선의 형태를 확인한 결과, 물이 분사되지 않는 경우에는 물이 분사되는 경우에 비해 가이드 베인을 따라 출구까지 일정하게 유동하였으며, 유동의 형태에 가이드 베인과 노즐의 배열 및 수압 등이 영향을 미치는 것으로 확인되었다. 와류형 스크러버의 경우 입 출구의 차압이 기존의 스크러버 대비 절반 이하로서 기관의 배압에 미치는 영향이 훨씬 적은 것으로 나타났다.

후박추출물의 나노입자화를 통한 치콘의 저장기간 연장 (Extension of Storage Time of Chicon using Nanoparticle of Machilus thunbergii Extracts)

  • 권민철;한재건;하지혜;김영;최근표;박욱연;이달호;이현용
    • 한국약용작물학회지
    • /
    • 제16권5호
    • /
    • pp.320-325
    • /
    • 2008
  • 치콘 및 엽채류의 저장기간 연장을 위해 천연보존제 및 천연항균제 선정을 위한 항균실험을 실시하고 후박 추출물이 미생물 최소 저해 농도 및 집락 형성 저해능이 높음을 확인하였다. 이를 엽채류에 도포함으로써 이들의 저장기간을 연장시키고자 수용성 추출물의 활용성을 극대화 할 수 있는 식용 나노입자를 제조하고 전자현미경 관찰 및 image anlyzer 측정을 통해 후박 추출물 나노입자의 80% 이상이 300nm 이하 크기로 형성되었음을 확인하였다. 투과전자현미경을 이용한 관찰을 통해서도 수십 nm $\sim$ 약 500nm 범위의 유사 구형 나노입자임을 확인하였으며, 엽채류 저장기간 연장 효과를 알아보고자 이 나노입자를 치콘 표면에 분무 도포하였다. 전자현미경을 통한 치콘 표면 촬영으로 도포된 후박 추출물 나노입자가 표면에 잔류하고 있음을 확인하였으며, HPLC 분석을 통해 후박 추출물을 서서히 방출하고 있음을 확인하였다. 나노입자를 도포한 치콘과 무처리 대조군의 저장기간에 따른 에틸렌 발생량을 GC로 측정한 결과, 입자를 도포한 치콘에서 초기 에틸렌 발생량이 높으나 저장기간에 따른 에틸렌 생성량의 증가를 억제해 7일 이후에는 발생량 자체도 적어졌음을 확인할 수 있었다. 이는 후박 추출물의 나노입자가 치콘의 세포호흡을 효과적으로 억제하는 것을 확인한 것으로 나노입자의 처리를 통해 저장기간의 연장효과를 나타내었다.

Determination of Optimal Storage Condition for Pre-packed Hanwoo Loin

  • Seol, Kuk-Hwan;Park, Tu San;Oh, Mi-Hwa;Park, Beom-Young;Cho, Seong In;Lee, Mooha
    • 한국축산식품학회지
    • /
    • 제33권3호
    • /
    • pp.390-394
    • /
    • 2013
  • The aim of this study was to determine the optimal storage condition of pre-packed Hanwoo beef without freezing. Hanwoo loin was purchased from a local distributor at 48 h after slaughter, then sliced in $1.5{\pm}0.5$ cm thickness, and packed in a polyethylene (PE) tray covered with linear low-density polyethylene (LLDPE) film. The studied factors to set the optimal storage condition were chamber temperature (5, 2.5 and $-1^{\circ}C$ for 14 d), cooling method (direct and indirect cooling system), and ultraviolet (UV) light irradiation for beef surface sterilization (0, 30, 60, and 120 min). The changes of pH, thiobarbituric acid reactive substances (TBARS) and number of aerobic bacteria were measured during storage. Beef samples stored in $-1^{\circ}C$ showed the minimal increasing rate in TBARS and microbial growth. After 15 d of storage, there was no significant difference in pH and TBARS values. However, the microbial population of beef stored in direct type cooling chamber ($4.25{\pm}0.66$ Log CFU/g) was significantly lower than that of beef stored in indirect type chamber ($6.47{\pm}0.08$ Log CFU/g) (p<0.05). After 4 d of storage, 60 or 120 min UV light irradiated beef samples showed significantly lower microbial population, and at 14 d of storage, 60 min UV irradiated beef sample showed significantly lower microbial population ($3.14{\pm}0.43$ Log CFU/g) than control ($4.46{\pm}0.13$ Log CFU/g) (p<0.05). However, TBARS values of 60 or 120 min UV light irradiated beef samples were significantly higher than non-irradiated beef sample after 4 d of storage (p<0.05).