Reference values for respiratory system impedance using impulse oscillometry in school-aged children in Korea

학동기 소아에서 impulse oscillometry system로 측정한 폐기능 정상치

  • Wee, Young Sun (Department of Pediatrics, College of Medicine, Pochon CHA University) ;
  • Kim, Hyoung Yun (Department of Pediatrics, College of Medicine, Pochon CHA University) ;
  • Jung, Da Wun (Department of Pediatrics, College of Medicine, Pochon CHA University) ;
  • Park, Hye Won (Department of Pediatrics, College of Medicine, Pochon CHA University) ;
  • Shin, Yoon Ho (Department of Pediatrics, College of Medicine, Pochon CHA University) ;
  • Han, Man Yong (Department of Pediatrics, College of Medicine, Pochon CHA University)
  • 위영선 (포천중문의과대학교 소아과학교실) ;
  • 김형윤 (포천중문의과대학교 소아과학교실) ;
  • 정다운 (포천중문의과대학교 소아과학교실) ;
  • 박혜원 (포천중문의과대학교 소아과학교실) ;
  • 신윤호 (포천중문의과대학교 소아과학교실) ;
  • 한만용 (포천중문의과대학교 소아과학교실)
  • Received : 2007.06.20
  • Accepted : 2007.07.11
  • Published : 2007.09.15

Abstract

Purpose : The impulse oscillometry (IOS) is applicable to young children because it requires minimal cooperation and a non-invasive method to measure the mechanics of respiratory system. This study aimed to develop the reference values in school-aged children in Korea, using IOS which is a modification of forced oscillation technique (FOT). Methods : Measurements were performed in 92 previously untrained healthy children, aged 7 to 12 years old, using IOS. We analyzed the relationships between the data about their age, height, weight, body surface area (BSA), body mass index (BMI) and the result of IOS using the linear regression test. Results : The success rate of IOS was 92.4%. Stepwise multiple regression of resistance of respiratory system (Rrs) and reactance of respiratory system (Xrs) in natural form for age, height, weight, BSA, BMI showed that height was the most significant predictor and altogether of 5 variables explained the Rrs and Xrs most. Our regression equations at multiple frequencys were comparable to published reference values, especially about the Rrs obtained at 5 Hz. Conclusion : IOS is a feasible method to measure the respiratory resistance in untrained children. We got the reference values using IOS and it seems to be useful to diagnose a variety of respiratory diseases.

목 적 : IOS는 호흡 노력을 요하지 않으며 호흡기 저항을 측정하는 비침습적인 방법이다. IOS를 이용하여 국내 학동기 소아에서의 표준치를 알아보고자 하였다. 방 법 : 7-12세의 건강한 소아 92명을 대상으로 IOS를 시행하였다. IOS 결과 값과 키, 몸무게, 체표 면적, 신체 질량 지수 및 나이 등의 연관성에 대하여 선형 회귀 분석을 시행하였다. 결 과 : IOS 성공률은 92.4%였다. 키, 몸무게, 체표 면적, 신체 질량 지수, 나이 등 5가지 변수값과 Rrs 및 Xrs를 분석한 결과, 키가 의미 있는 예측 인자였으며, 5가지 변수 모두 적용한 경우 가장 설명력이 높았다. 각각의 주파수에 따라 회귀 곡선 공식을 구하였으며, 이는 이전 연구들의 표준 공식과 비슷하였다. 결 론 : IOS의 표준치를 구하였으며 이를 활용하여 다양한 호흡기 질환의 진단에 활용될 수 있을 것이라 여겨진다.

Keywords

References

  1. Blonshine SB. Pediatric pulmonary function testing. Respir Care Clin N Am 2000;6:27-40 https://doi.org/10.1016/S1078-5337(05)70056-3
  2. Godfrey S, Bar-Yishay E, Avital A, Springer C. What is the role of tests of lung function in the management of infants with lung disease? Pediatr Pulmonol 2003;36:1-9 https://doi.org/10.1002/ppul.10282
  3. Nielsen KG. Forced oscillation technique. Paediatr Respir Rev 2006;7 Suppl 1:8-10 https://doi.org/10.1016/j.prrv.2006.04.021
  4. Ducharme F, Davis G, Ducharme G. Pediatric reference values for respiratory resistance measured by forced oscillation. Chest 1998;113:1322-8 https://doi.org/10.1378/chest.113.5.1322
  5. Lebecque P, Stanescu D. Respiratory resistance by the forced oscillation technique in asthmatic children and cystic fibrosis patients. Eur Respir J 1997;10:891-5
  6. Hellinckx J, Cauberghs M, De Boeck K, Demedts M. Evaluation of impulse oscillation system: Comparison with forced oscillation technique and body plethysmography. Eur Respir J 2001;18:564-70 https://doi.org/10.1183/09031936.01.00046401
  7. Park YM. Lung function tests in preschool children. Korean J Pediatr 2007;50:422-9 https://doi.org/10.3345/kjp.2007.50.5.422
  8. Ducharme FM, Davis GM. Measurement of respiratory resistance in the emergency department: Feasibility in young children with acute asthma. Chest 1997;111:1519-25 https://doi.org/10.1378/chest.111.6.1519
  9. Lebecque P, Desmond K, Swartebroeckx Y, Dubois P, Lulling J, Coates A. Measurement of respiratory system resistance by forced oscillation in normal children: A comparison with spirometric values. Pediatr Pulmonol 1991;10:117-22 https://doi.org/10.1002/ppul.1950100214
  10. Dencker M, Malmberg LP, Valind S, Thorsson O, Karlsson MK, Pelkonen A, et al. Reference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years. Clin Physiol Funct Imaging 2006;26:247-50 https://doi.org/10.1111/j.1475-097X.2006.00682.x
  11. Frei J, Jutla J, Kramer G, Hatzakis GE, Ducharme FM, Davis GM. Impulse oscillometry: Reference values in children 100 to 150 cm in height and 3 to 10 years of age. Chest 2005;128:1266-73 https://doi.org/10.1378/chest.128.3.1266
  12. Stocks J, Quanjer PH. Reference values for residual volume, functional residual capacity and total lung capacity. ATS workshop on lung volume measurements. official statement of the european respiratory society. Eur Respir J 1995;8:492-506 https://doi.org/10.1183/09031936.95.08030492
  13. Oostveen E, MacLeod D, Lorino H, Farre R, Hantos Z, Desager K, et al. The forced oscillation technique in clinical practice: Methodology, recommendations and future developments. Eur Respir J 2003;22:1026-41 https://doi.org/10.1183/09031936.03.00089403
  14. Malmberg LP, Pelkonen A, Poussa T, Pohianpalo A, Haahtela T, Turpeinen M. Determinants of respiratory system input impedance and bronchodilator response in healthy finnish preschool children. Clin Physiol Funct Imaging 2002; 22:64-71 https://doi.org/10.1046/j.1475-097X.2002.00396.x
  15. Olinsky A, Bryan AC, Bryan MH. A simple method of measuring total respiratory system compliance in newborn infants. S Afr Med J 1976;50:128-30
  16. Bridge PD, Ranganathan S, McKenzie SA. Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting. Eur Respir J 1999;13:792-6. https://doi.org/10.1034/j.1399-3003.1999.13d16.x
  17. Vilozni D, Barker M, Jellouschek H, Heimann G, Blau H. An interactive computer-animated system (SpiroGame) facilitates spirometry in preschool children. Am J Respir Crit Care Med 2001;164:2200-5 https://doi.org/10.1164/ajrccm.164.12.2101002
  18. Dubois AB, Brody AW, Lewis DH, Burgess BR. Oscillation mechanics of lungs and chest in man. J Appl Physiol 1956; 8:587-94 https://doi.org/10.1152/jappl.1956.8.6.587
  19. Buhr W, Jorres R, Berdel D, Landser FJ. Correspondence between forced oscillation and body plethysmography during bronchoprovocation with carbachol in children. Pediatr Pulmonol 1990;8:280-8 https://doi.org/10.1002/ppul.1950080413
  20. Bisgaard H, Klug B. Lung function measurement in awake young children. Eur Respir J 1995;8:2067-75 https://doi.org/10.1183/09031936.95.08122067
  21. Marchal F, Mazurek H, Habib M, Duvivier C, Derelle J, Peslin R. Input respiratory impedance to estimate airway hyperreactivity in children: Standard method versus head generator. Eur Respir J 1994;7:601-7 https://doi.org/10.1183/09031936.94.07030601
  22. Delacourt C, Lorino H, Herve-Guillot M, Reinert P, Harf A, Housset B. Use of the forced oscillation technique to assess airway obstruction and reversibility in children. Am J Respir Crit Care Med 2000;161:730-6. https://doi.org/10.1164/ajrccm.161.3.9904081
  23. Delacourt C, Lorino H, Fuhrman C, Herve-Guillot M, Reinert P, Harf A, et al. Comparison of the forced oscillation technique and the interrupter technique for assessing airway obstruction and its reversibility in children. Am J Respir Crit Care Med 2001;164:965-72 https://doi.org/10.1164/ajrccm.164.6.2010153
  24. Solymar L, Aronsson PH, Sixt R. The forced oscillation technique in children with respiratory disease. Pediatr Pulmonol 1985;1:256-61 https://doi.org/10.1002/ppul.1950010507
  25. Hellinkx J, De Boeck K, Bande-Knops J. van der Poel M, Demedts M. Bronchodilator response in 3-6.5 years okl healthy and stable asthmatic children. Eur Respir J 1998;12;438-43 https://doi.org/10.1183/09031936.98.12010003