• 제목/요약/키워드: Microwave-excited plasma

검색결과 12건 처리시간 0.027초

Advanced Microwave Plasma Technology for Liquid Treatment

  • Toyoda, Hirotaka;Takahashi, T.;Takada, N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.121.1-121.1
    • /
    • 2014
  • Recently, much attention has been given to plasma production under liquid and its applications [1]. However, most of plasma production techniques reported so far utilize high voltage dc, ac, rf or microwave power [2], where damage to discharge electrodes and small discharge volume are remained issues. As an alternative of plasma production method under liquid, we have proposed pulsed microwave excited plasma using slot antenna, where damage to the slot electrode can be minimized and plasma volume can be increased. We have also reported improvement of treatment efficiency with use of reduced-pressure condition during the discharge [3]. To realize low pressure conditions in liquid, various alternative technique can be considered. One possible technique is simultaneous injection of microwave power and ultrasonic wave. Ultrasonic wave induces pressure fluctuation with the wave propagation and is so far used for cavitation production in the water. We propose utilization of reduced pressure induced by ultrasonic cavitation for improvement of the plasma production. Correlation between the plasma production and the ultrasonic power will be discussed.

  • PDF

Gas phase diagnostics of high-density $SiH_4/H_2$ microwave plasma

  • Toyoda, Hirotaka;Kuroda, Toshiyuki;Ikeda, Masahira;Sakai, Junji;Ito, Yuki;Ishijima, Tatsuo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.94-94
    • /
    • 2010
  • As a new plasma source for the plasma enhanced chemical vapor deposition (PCVD) of ${\mu}c$-Si deposition, we have demonstrated a microwave-excited plasma source, which can produce high density (${\sim}10^{12}\;cm^{-3}$) plasma with low electron temperature (~1 eV) and low plasma potential (~10 V). In this plasma source, microwave power radiated from slot antenna is distributed along the plasma-dielectric interface in large area and this enables us to produce uniform high-density plasma in large area. To optimize deposition conditions, deep understanding of gas phase chemistry is indispensable. In this presentation, we will discuss on the gas phase diagnostics of microwave $SiH_4/H_2$ plasma such as $SiH_4$ dissociation or $SiH_3$ radical profile as well as deposited film properties.

  • PDF

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF

A Inclined Slot-excited Circular Plasma Source with a Cusp Magnetic Field

  • You, H.J.;Kim, D.W.;Koo, M.;Jang, S.W.;Jung, Y.H.;Lee, B.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.435-435
    • /
    • 2010
  • A inclined slot-excited plasma source is newly designed and constructed for higher flux HNB(Hyperthermal Neutral Beam) generation. The present source is different from the vertical SLAN(SLot ANtenna) sources [1] in two aspects. One is that the slots are inclined, and the other is that the magnetic field is configured to a cusp type. These modifications are intended to make the source plasma operated in sub-milli-torr pressure regime and as thin as possible, both of which is to get higher HNB flux by decreasing the re-ionization rate of the reflected atoms from the neutralizer [2]. The plasma is generated in a quartz tube of internal diameter 170 mm enclosed in a aluminum application chamber of larger diameter 250 mm. The microwave power is fed to the plasma chamber by 8 inclined slots cut into the application chamber wall. The slots are coupled the chamber to a WR280 waveguide wound around it to form a ring resonator. In order to make two slots $\lambda_g/2$ apart in phase, the adjacent slots are rotated in opposite directions. The rotation angle of the slots are set to $60^{\circ}$ from the chamber axis. Between the quartz chamber and the aluminum cylindrical chamber 8 NdFeB magnets are equally spaced and fixed to form the cusp magnetic field confinement and ECR (Electron Cyclotron Resonance) field. In this presentation, the magnetic and electromagnetic simulations, and the measured plasma parameters are given for both the inclined and the vertical slot-excited plasma sources. We also discuss how the sources can be tailored to suit better-performing HNB sources.

  • PDF

마이크로파 여기 프라즈마법으로 제조한 강자성 터널링 접합의 국소전도특성 (Local Current Distribution in a Ferromagnetic Tunnel Junction Fabricated Using Microwave Excited Plasma Method)

  • 윤대식;김철기;김종오
    • 한국자기학회지
    • /
    • 제13권2호
    • /
    • pp.47-52
    • /
    • 2003
  • DC 마그네트론 스파터법과 RLSA(Radial Line Slot Antenna)을 이용한 마이크로파 여기 프라즈마를 이용하여 Ta/Cu/Ta/NiFe/Cu/Mn$_{75}$Ir$_{25}$/ $Co_{70}$Fe$_{30}$/Al-oxide 구조의 접합을 제조한 후, contact-mode AM(Atomic Force Microscope)을 이용하여 Al 산화막의 국소전도 특성의 평가를 수행하였다. AFM 동시전류측정으로부터, 얻어지는 표면상과 전류상은 대응하지 않는다. 국소 전류-전압(I-V)의 측정 결과, 전류상은 절연층의 barrier height의 분포를 나타내고 있다는 것을 알았다.다.다.

원편광 초고주파를 이용한 무전극 플라즈마 광원 응용 연구 (Applications of the Electrodeless Plasma Light Excited by Circularly Polarized Microwave Discharges)

  • 원동호;김경신;윤현성;백진수;김진중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1281-1282
    • /
    • 2015
  • 본 논문에서는 원편광 초고주파를 이용한 무전극 플라즈마 광원 기술과 광원의 특성을 논의한다. 특히 비회전 무전극 플라즈마 광원을 Solar Simulator용 광원으로 적용하여 그 특성을 설명한다.

  • PDF

질화법으로 제작한 강자성 터널링 접합의 국소전도 및 자기저항 특성 (Local Investigation and Magnetoresistance Properties of Co-Fe/Al-N/Co-Fe Tunnel Junctions Nitrided by Microwave-excited Plasma)

  • 윤대식;;;박범찬;이영우;이영;김종오
    • 한국재료학회지
    • /
    • 제14권3호
    • /
    • pp.191-195
    • /
    • 2004
  • Tunnel junctions with AI-N barriers fabricated by microwave-excited plasma were studied. When the Al thickness, nitridation time, and annealing temperature were 1 nm (0.8 nm), 50 s (35 s), and $280^{\circ}C$ ($300^{\circ}C$), TMR ratio and resistance-area product (RA) were 49% (34%) and $3 ${\times}$ 10^4$ $\Omega$$\mu\m^2$ ($1.5 ${\times}$ 10^4$ $\Omega$$\mu\m^2$), respectively. In order to clarify the annealing temperature dependence of TMR ratio, the local transport properties were measured for Ta 5 nm/Cu 20 nm/Ta 5 nm$29_{76}$ $Fe_{24}$ 2 nm/Cu 5 nm/M $n_{75}$$Ir_{25}$ 10 nm/ $Co_{71}$ $Co_{29}$ 4nm/Al-N junction with Al thickness of 0.8 nm and nitridation time of 35s at various temperatures. The increase of TMR ratio after annealing at $300^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 34%, can be well explained by the enhancement of the average barrier height ($\Phi_{ave}$) and the reduction of its fluctuation. After further annealing at $340^{\circ}C$, the leakage current was observed and the TMR ratio decreaseded

Magnetic Tunnel Junctions with AlN and AlO Barriers

  • Yoon, Tae-Sick;Yoshimura, Satoru;Tsunoda, Masakiyo;Takahashi, Migaku;Park, Bum-Chan;Lee, Young-Woo;Li, Ying;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • 제9권1호
    • /
    • pp.17-22
    • /
    • 2004
  • We studied the magnetotransport properties of tunnel junctions with AlO and AlN barriers fabricated using microwave-excited plasma. The plasma nitridation process provided wider controllability than the plasma oxidization for the formation of MTJs with ultra-thin insulating layer, because of the slow nitriding rate of metal Al layers, comparing with the oxidizing rate of them. High tunnel magnetoresistance (TMR) ratios of 49 and 44% with respective resistance-area product $(R{\times}A) of 3 {\times} 10^4 and 6 {\times} 10^3 {\Omega}{\mu}m^2$ were obtained in the Co-Fe/Al-N/Co-Fe MTJs. We conclude that AlN is a hopeful barrier material to realize MTJs with high TMR ratio and low $R{\times}A$ for high performance MRAM cells. In addition, in order to clarify the annealing temperature dependence of TMR, the local transport properties were measured for Ta $50{\AA} /Cu 200 {\AA}/Ta 50 {\AA}/Ni_{76}Fe_{24} 20 {\AA}/Cu 50 {\AA}/Mn_{75}Ir_{25} 100 {\AA}/Co_{71}Fe_{29} 40 {\AA}/Al-O$ junction with $d_{Al}= 8 {\AA} and P_{O2}{\times}t_{0X}/ = 8.4 {\times} 10^4$ at various temperatures. The current histogram statistically calculated from the electrical current image was well in accord with the fitting result considering the Gaussian distribution and Fowler-Nordheim equation. After annealing at $340^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 44%, the average barrier height increased to 1.12 eV and its standard deviation decreased to 0.1 eV. The increase of TMR ratio after annealing could be well explained by the enhancement of the average barrier height and the reduction of its fluctuation.