• Title/Summary/Keyword: Microprocessor Control

Search Result 724, Processing Time 0.026 seconds

Optimal Starting Torque Control of Wound Rotor Induction Motor by Microprocessor (개용분 PFN-PMW의 유전특성에 관한 연구)

  • Park, Min-Ho;Jung, So-Woong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.316-324
    • /
    • 1984
  • In the wound rotor induction motor, the external resistor is usually added to the rotor circuit in order to limit the starting current. In this scheme, whilst the starting current is limited, the available torque is remarkably reduced. In this paper, to improve the starting characteristics the stator current can be maintained constant by adjusting the external resistor. To change the external resistor, teh chopper and the resistor is connected in parallel, and the chopper duty cycle is adjusted by microprocessor. The duty cycle is calculated according to the actual speed of motor by microprocessor look-up table map. In this suggested scheme, the starting characteristics are remarkably improved without over-current. The starting time of this system is reduced by 20-48 Percent compared with fixed extemal resistance system in the same load.

  • PDF

Tracking Control of Maximum Power Point of Photovoltaic Array by using the Microprocessor (Microprocessor를 이용한 태양전지의 최대 출력점 추적 제어)

  • Han, K.H.;Jang, K.H.;Kwon, H.;Kim, D.K.;Lee, W.K.;Kang, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.492-495
    • /
    • 1991
  • This paper proposes the microprocessor-based step-up chopper system used for the battery charge from the photovoltaic arrays. The proposed scheme tracks the maximum power point by analyzing the voltage and power phasors which vary as the solar irradiation quantity. In this system, protection for the overcharge and overdischarge in also provided.

  • PDF

The Design of a Real-Time Simulator on the Hydraulic Servo System

  • Chang, Sung-Ouk;Lee, Jin-Kul
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2003
  • In this study we suggest real-time simulator that could describe rent system without ordinary DSP card. This simulator is composed of 80196kc-16bit ordinary microprocessor, which is widely used up to now and personal computer. DSP card that has calculated complex numerical equation is replaced by personal computer and 80196kc generates control signals independently out of the personal computer. In all process personal computer is synchronized with one-board microprocessor (80196kc) within sampling time in the closed loop system. This makes it possible to be described in hydraulic servo system in real time.

Microprocessor Control in D-4 Channel Bank (D-4PCM 단말장치에의 마이크로프로세서 응용)

  • 송상훈;김영균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.6
    • /
    • pp.40-47
    • /
    • 1979
  • In the recent developent of D-4 Channel Bank which is the basic PCM multiplex terminal, we utilized the one-chip microprocessor in the design of the Alarm and Trunk processing unit besides we could add more flexible functions, we simplified the logic circuits and the discrete parts. Since in Korea, we are lacking in the semiconductor technology, the microprocessor applications in the communication systems desist give us the meaningful advantages in the a aspects of economy, reliability and new technology.

  • PDF

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

A novel PWM control of Full-bridge Inverters for Microprocessor Implementation (마이크로프로세서 구현에 의한 전파 브리지 인버터의 새로운 PWM 제어)

  • 전칠환;이수원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.283-288
    • /
    • 2000
  • This paper proposes a novel Pulse Width Modulation (PWM) method for microprocessor implementation of full-bridge PWM inverters. In the method, the period of unipolar full-bridge inverters is divided equally into the frequency modulation ratio and the reference fundamental amplitude and the inverter output fundamental amplitude are compared. Using this method, the turn-on time computation of each interval is very favored for the microprocessor implementation. The harmonic analysis shows that the harmonics can be ignored when the modulation ratio is enough large. The simulation and experimental results show the effectiveness of the proposed algorithms.

  • PDF

A Study on A Microprocessor-Based Incremental Servo System with Variable Structure. (마이크로 프로세서를 이용한 가변구조를 갖는 서어보 시스템에 관한 연구)

  • Lee, Sang-Bum;Kim, Su-Il;Hong, Kun-Hwan;Choi, Seung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.301-303
    • /
    • 1987
  • A microprocessor-based incremental servo system with a variable structure is presented. New system properties are obtained by composing a desired trajectory from the parts of trajectories of different structures. It is implemented with Z-80A microprocessor to control a dc motor, and fast response without overshoot and good steady-state accuracy can be easily obtained.

  • PDF

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

Digital-To-Phase-Shift PWM Circuit for Full Digital Controlled FB DC/DC Converter

  • Kim, Eun-Soo;Choi, Hae-Young;Park, Soon-Gu;Kim, Tae-Jin;Kim, Yoon-Ho;Lee, Jae-Hak
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.442-446
    • /
    • 1998
  • With the advent of the high-speed microprocessor and DSP, the possibility of executing a control strategy in digital domain has become a reality. By the use of the DSP and microprocessor controller, many high power converters such as especially inverter and motor drive system may be enhanced resulting in the improved robustness to EMI, the ability to communicate the operating conditions and the ease of adjusting the control parameters. But, the digital controller using DSP or microprocessor is not applied in the high frequency switching power supplies, especially full bridge dc/dc converter. So, this paper presents the method and realization of designing a digital-to-phase shift PWM circuit for full digital controlled phase-shifted full bridge dc/dc converter with zero voltage switching. The operating principles, simulation and experimental results will be presented.

  • PDF

A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF